Mobile fire extinguishers - Part 1: Characteristics, performance and test methods

Published date

01-08-2007

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Description of an extinguisher
  5.1 Type of extinguisher
  5.2 Components of extinguisher
6 Requirements
  6.1 Effective range of operating temperatures
       6.1.1 General
       6.1.2 Requirements
       6.1.3 Additional Requirements for
             CO[2] extinguishers
  6.2 Filling specifications
       6.2.1 Nominal charges
       6.2.2 Filling tolerances
       6.2.3 Propelling agent
  6.3 Duration of operation, residual mass and
       discharge range
       6.3.1 Duration of operation
       6.3.2 Maximum residual mass
  6.4 Retention of propellant
       6.4.1 General
       6.4.2 Propellant container
       6.4.3 Stored pressure extinguishers
       6.4.4 Acceptance levels
  6.5 Control valve
  6.6 Working position
  6.7 Hose and coupling
  6.8 Operation devices
       6.8.1 General
       6.8.2 Operating and jet control mechanisms devices
       6.8.3 Safety devices
       6.8.4 Discharge from water based extinguishers
       6.8.5 Pressure gauge
       6.8.6 Other characteristics
  6.9 Identification
       6.9.1 Colour
       6.9.2 Marking
  6.10 Periodical checking
7 Tests
  7.1 Temperature test
  7.2 Corrosion tests
       7.2.1 External corrosion test
       7.2.2 Internal corrosion test for water
             based extinguishers
  7.3 Dielectric test
8 Fire performances
  8.1 Class A fire test object
       8.1.1 General
       8.1.2 Powder extinguishers
       8.1.3 Water based extinguishers
  8.2 Class B fire test object
       8.2.1 General
       8.2.2 Powder extinguishers
       8.2.3 Water based extinguishers
       8.2.4 CO[2] extinguishers
Annex A (normative) - Test methods
      A.1 Test methods
      A.2 Duration of operation and residual mass
      A.3 Measurement of the force
      A.4 Measurement of the energy
      A.5 Measurement of leakage of the
          control valve
      A.6 Temperatures test
      A.7 Internal corrosion test
Bibliography

This European Standard specifies the rules of design, type testing and inspection during manufacturing, ratings and classification of mobile fire extinguishers and test methods to be used. It applies to mobile fire extinguishers with a total mass above 20 kg for powder, water based and CO2 extinguishers. This standard applies to mobile fire extinguishers that are manoeuvred by an operator on foot only.It does not cover fire tests for class C and class F fires, but the used extinguishing media can be effective on these types of fire. Class D fires are considered to be a very specialist application and are not included in this standard, but may be made the object of national specification.

Committee
CEN/TC 70
DevelopmentNote
Together with EN 1866-2 & EN 1866-3, it supersedes EN 1866. (05/2014)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

Standards Relationship
I.S. EN 1866-1:2007 Identical
NF EN 1866-1 : 2007 Identical
UNI EN 1866-1 : 2008 Identical
NBN EN 1866-1 : 2008 Identical
NEN EN 1866-1 : 2007 Identical
DIN EN 1866-1:2007-10 Identical
NS EN 1866-1 : 1ED 2007 Identical
UNE-EN 1866-1:2008 Identical
SN EN 1866-1 : 2008 Identical
BS EN 1866-1:2007 Identical

I.S. EN 1866-3:2013 MOBILE FIRE EXTINGUISHERS - PART 3: REQUIREMENTS FOR THE ASSEMBLY, CONSTRUCTION AND PRESSURE RESISTANCE OF CO[2] EXTINGUISHERS WHICH COMPLY WITH THE REQUIREMENTS OF EN 1866-1
BS EN 1866-2:2014 Mobile fire extinguishers Requirements for the construction, pressure resistance and mechanical tests for extinguishers, with a maximum allowable pressure equal to or lower than 30 bar, which comply with the requirements of EN 1866-1
DIN EN 1866-3:2013-08 Mobile fire extinguishers - Part 3: Requirements for the assembly, construction and pressure resistance of CO2 extinguishers which comply with the requirements of EN 1866-1
12/30266856 DC : 0 BS EN 1866-3 - MOBILE FIRE EXTINGUISHERS - PART 3: REQUIREMENTS FOR THE ASSEMBLY, CONSTRUCTION AND PRESSURE RESISTANCE OF CO[2] EXTINGUISHERS WHICH COMPLY WITH THE REQUIREMENTS OF EN 1866-1
BS EN 1866-3:2013 Mobile fire extinguishers Requirements for the assembly, construction and pressure resistance of CO<sub>2</sub> extinguishers which comply with the requirements of EN 1866-1
EN 1866-3:2013 Mobile fire extinguishers - Part 3: Requirements for the assembly, construction and pressure resistance of CO2 extinguishers which comply with the requirements of EN 1866-1
EN 1866-2:2014 Mobile fire extinguishers - Part 2: Requirements for the construction, pressure resistance and mechanical tests for extinguishers, with a maximum allowable pressure equal to or lower than 30 bar, which comply with the requirements of EN 1866-1
12/30266853 DC : 0 BS EN 1866-2 - MOBILE FIRE EXTINGUISHERS - PART 2: REQUIREMENTS FOR THE CONSTRUCTION, PRESSURE RESISTANCE AND MECHANICAL TESTS FOR EXTINGUISHERS, WITH A MAXIMUM ALLOWABLE PRESSURE EQUAL TO OR LOWER THAN 30 BAR, WHICH COMPLY WITH THE REQUIREMENTS OF EN 1866-1
UNI EN 1866-3 : 2013 MOBILE FIRE EXTINGUISHERS - PART 3: REQUIREMENTS FOR THE ASSEMBLY, CONSTRUCTION AND PRESSURE RESISTANCE OF CO[2] EXTINGUISHERS WHICH COMPLY WITH THE REQUIREMENTS OF EN 1866-1
I.S. EN 1866-2:2014 MOBILE FIRE EXTINGUISHERS - PART 2: REQUIREMENTS FOR THE CONSTRUCTION, PRESSURE RESISTANCE AND MECHANICAL TESTS FOR EXTINGUISHERS, WITH A MAXIMUM ALLOWABLE PRESSURE EQUAL TO OR LOWER THAN 30 BAR, WHICH COMPLY WITH THE REQUIREMENTS OF EN 1866-1
UNE-EN 1866-3:2015 Mobile fire extinguishers - Part 3: Requirements for the assembly, construction and pressure resistance of CO2 extinguishers which comply with the requirements of EN 1866-1
UNI EN 1866-2 : 2014 MOBILE FIRE EXTINGUISHERS - PART 2: REQUIREMENTS FOR THE CONSTRUCTION, PRESSURE RESISTANCE AND MECHANICAL TESTS FOR EXTINGUISHERS, WITH A MAXIMUM ALLOWABLE PRESSURE EQUAL TO OR LOWER THAN 30 BAR, WHICH COMPLY WITH THE REQUIREMENTS OF EN 1866-1
UNE-EN 1866-2:2015 Mobile fire extinguishers - Part 2: Requirements for the construction, pressure resistance and mechanical tests for extinguishers, with a maximum allowable pressure equal to or lower than 30 bar, which comply with the requirements of EN 1866-1

EN ISO 9227:2017 Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2017)
EN 3-7:2004+A1:2007 Portable fire extinguishers - Part 7: Characteristics, performance requirements and test methods
ISO 9227:2017 Corrosion tests in artificial atmospheres — Salt spray tests

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more