Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 1822-2:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

High efficiency air filters (EPA, HEPA and ULPA) - Part 2: Aerosol production, measuring equipment, particle counting statistics

Superseded date

26-02-2020

Published date

18-11-2009

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Aerosol production
5 Measuring devices
6 Maintenance and inspection intervals
7 Particle counting statistics
Bibliography

This European Standard applies to efficient particulate air filters (EPA), high efficiency particulate air filters (HEPA) and ultra low penetration air filters (ULPA) used in the field of ventilation and air conditioning and for technical processes, e.g. for applications in clean room technology or pharmaceutical industry.It establishes a procedure for the determination of the efficiency on the basis of a particle counting method using a liquid (or alternatively a solid) test aerosol, and allows a standardized classification of these filters in terms of their efficiency, both local and integral efficiency.This European Standard describes the measuring instruments and aerosol generators used in the course of this testing. With regard to particle counting it specifies the statistical basis for the evaluation of counts with only small numbers of counted events.

Committee
CEN/TC 195
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
NBN EN 1822-2 : 2010 Identical
SN EN 1822-2 : 2010 Identical
UNE-EN 1822-2:2010 Identical
NF EN 1822-2 : 2010 Identical
DIN EN 1822-2:2011-01 Identical
I.S. EN 1822-2:2009 Identical
ONORM EN 1822-2 : 2010 Identical
PN EN 1822-2 : 2009 Identical
NEN EN 1822-2 : 2009 Identical
UNI EN 1822-2 : 2010 Identical
BS EN 1822-2:2009 Identical
NS EN 1822-2 : 2009 Identical
SS-EN 1822-2:2009 Identical

ISO 29463-1:2017 High efficiency filters and filter media for removing particles from air — Part 1: Classification, performance, testing and marking
I.S. EN 13824:2005 STERILIZATION OF MEDICAL DEVICES - ASEPTIC PROCESSING OF LIQUID MEDICAL DEVICES - REQUIREMENTS
09/30182875 DC : 0 BS ISO 29463-4 - HIGH-EFFICIENCY FILTERS AND FILTER MEDIA FOR REMOVING PARTICLES FROM AIR - PART 4: TEST METHOD FOR DETERMINING THE LEAKAGE OF FILTER ELEMENTS (SCAN METHOD)
03/317114 DC : DRAFT OCT 2003 EN 14799 - AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY
DIN EN 1822-4:2011-01 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD)
UNI EN 1822-3 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA
DIN EN 1822-5:2011-01 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS
NF EN 1822-5 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS
I.S. EN 1822-5:2009 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS
EN 1822-5:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements
UNE-EN 1822-4:2010 High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method)
NF EN 1822-4 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD)
UNI EN 1822-4 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD)
NF EN 1822-3 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA
I.S. EN ISO 14644-3:2006 CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS
BS EN ISO 16000-7:2007 Indoor air Sampling strategy for determination of airborne asbestos fibre concentrations
BS EN 13824:2004 Sterilization of medical devices. Aseptic processing of liquid medical devices. Requirements
ISO 29463-2:2011 High-efficiency filters and filter media for removing particles in air — Part 2: Aerosol production, measuring equipment and particle-counting statistics
BS EN 15695-2:2017 Agricultural tractors and self-propelled sprayers. Protection of the operator (driver) against hazardous substances Filters, requirements and test procedures
15/30329404 DC : 0 BS EN 15695-2 - AGRICULTURAL TRACTORS AND SELF-PROPELLED SPRAYERS - PROTECTION OF THE OPERATOR (DRIVER) AGAINST HAZARDOUS SUBSTANCES - PART 2: FILTERS, REQUIREMENTS AND TEST PROCEDURES
NF ISO 12500-3 : 2009 FILTERS FOR COMPRESSED AIR - TEST METHODS - PART 3: PARTICULATES
BS EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) Classification, performance testing, marking
DIN EN 1822-1:2011-01 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING
I.S. EN 1822-4:2009 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD)
UNI EN 1822-1 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING
EN 15695-2:2017 Agricultural tractors and self-propelled sprayers - Protection of the operator (driver) against hazardous substances - Part 2: Filters, requirements and test procedures
ISO 29463-3:2011 High-efficiency filters and filter media for removing particles in air — Part 3: Testing flat sheet filter media
EN 1822-4:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method)
BS EN 1822-3:2009 High efficiency air filters (EPA, HEPA and ULPA) Testing flat sheet filter media
BS EN 1822-4:2009 High efficiency air filters (EPA, HEPA and ULPA) Determining leakage of filter elements (scan method)
EN 1822-3:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media
I.S. EN 1822-1:2009 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING
BS EN ISO 14644-4:2001 Cleanrooms and associated controlled environments Design, construction and start-up
VDI 6300 Blatt 1:2016-05 Genetic engineering operations in genetic engineering facilities - Guidance on safe operation of genetic engineering facilities
VDI 2083 Blatt 3:2005-07 Cleanroom technology - Metrology and test methods
16/30326493 DC : 0 BS EN ISO 14644-3 - CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS
08/30176852 DC : DRAFT APR 2008 BS EN 1822-4 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 4: DETERMINING LEAKAGE OF FILTER ELEMENTS (SCAN METHOD)
08/30176848 DC : DRAFT APR 2008 BS EN 1822-3 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA
BS ISO 12500-3:2009 Filters for compressed air. Test methods Particulates
PREN 15695-2 : DRAFT 2015 AGRICULTURAL TRACTORS AND SELF-PROPELLED SPRAYERS - PROTECTION OF THE OPERATOR (DRIVER) AGAINST HAZARDOUS SUBSTANCES - PART 2: FILTERS, REQUIREMENTS AND TEST PROCEDURES
EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
ISO 29463-4:2011 High-efficiency filters and filter media for removing particles in air — Part 4: Test method for determining leakage of filter elements-Scan method
UNE-EN 1822-3:2010 High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media
I.S. EN 1822-3:2009 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA
BS EN 1822-5:2009 High efficiency air filters (EPA, HEPA and ULPA) Determining the efficiency of filter elements
DIN EN 1822-3:2011-01 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 3: TESTING FLAT SHEET FILTER MEDIA
UNI EN 1822-5 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS
DIN EN ISO 14644-3:2006-03 CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS
ISO 16000-7:2007 Indoor air — Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations
BS EN 14799:2007 Air filters for general air cleaning. Terminology
I.S. EN 14799:2007 AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY
UNI EN 14799 : 2008 AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY
09/30182882 DC : 0 BS ISO 29463-5 - HIGH-EFFICIENCY FILTERS AND FILTER MEDIA FOR REMOVING PARTICLES FROM AIR - PART 5: TEST METHOD FOR DETERMINING THE EFFICIENCY OF FILTER ELEMENTS
07/30164823 DC : 0 BS EN 15695-2 - AGRICULTURAL TRACTORS AND SELF-PROPELLED MACHINERY - PROTECTION AGAINST HAZARDOUS SUBSTANCES - PART 2: AIR PURIFYING DEVICES
07/30164305 DC : 0 BS ISO 12500-3 - FILTERS FOR COMPRESSED AIR - TEST METHODS - PART 3: PARTICULATES
08/30176838 DC : DRAFT APR 2008 BS EN 1822-1 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING
ISO 12500-3:2009 Filters for compressed air Test methods Part 3: Particulates
UNE-EN 15695-2:2010 Agricultural tractors and self-propelled sprayers - Protection of the operator (driver) against hazardous substances - Part 2: Filters, requirements and test procedures
UNE-EN 1822-1:2010 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
ISO 29463-5:2011 High-efficiency filters and filter media for removing particles in air Part 5: Test method for filter elements
UNE-EN 1822-5:2010 High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements
ISO 14644-4:2001 Cleanrooms and associated controlled environments — Part 4: Design, construction and start-up
BS EN ISO 14644-3:2005 Cleanrooms and associated controlled environments Test methods
ISO 26802:2010 Nuclear facilities Criteria for the design and the operation of containment and ventilation systems for nuclear reactors
EN ISO 16000-7:2007 Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations (ISO 16000-7:2007)
EN 14799:2007 Air filters for general air cleaning - Terminology
EN ISO 14644-4:2001 Cleanrooms and associated controlled environments - Part 4: Design, construction and start-up (ISO 14644-4:2001)
EN ISO 14644-3:2005 Cleanrooms and associated controlled environments - Part 3: Test methods (ISO 14644-3:2005)
EN 13824:2004 Sterilization of medical devices - Aseptic processing of liquid medical devices - Requirements
I.S. EN 15695-2:2017 AGRICULTURAL TRACTORS AND SELF-PROPELLED SPRAYERS - PROTECTION OF THE OPERATOR (DRIVER) AGAINST HAZARDOUS SUBSTANCES - PART 2: FILTERS, REQUIREMENTS AND TEST PROCEDURES
11/30232479 DC : 0 BS ISO 3857-4 - COMPRESSOR, PNEUMATIC TOOLS AND MACHINES - VOCABULARY - PART 4: AIR TREATMENT
08/30176855 DC : DRAFT APR 2008 BS EN 1822-5 - HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 5: DETERMINING THE EFFICIENCY OF FILTER ELEMENTS
NF EN 1822-1 : 2010 HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING
SAE AIR 4766/1 : 2011 AIR QUALITY FOR COMMERCIAL AIRCRAFT CABIN - PARTICULATE CONTAMINANTS
ISO 14644-3:2005 Cleanrooms and associated controlled environments Part 3: Test methods
BS ISO 26802:2010 Nuclear facilities. Criteria for the design and the operation of containment and ventilation systems for nuclear reactors
DIN EN 13824:2005-02 STERILIZATION OF MEDICAL DEVICES - ASEPTIC PROCESSING OF LIQUID MEDICAL DEVICES - REQUIREMENTS

EN 1822-5:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements
VDI 3491 Blatt 1:2016-07 Measurement of particles - Methods for generating test aerosols - Principles and overview
VDI 3489 Blatt 2:1995-12 Particulate matter measurement - Methods for characterizing and monitoring test aerosols - Continuous flow condensation nucleus counter
VDI 2080:1996-04 Measuring methods and measuring instruments for air-conditioning systems
EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
ISO 14644-3:2005 Cleanrooms and associated controlled environments Part 3: Test methods
VDI 3489 Blatt 3:1997-03 Particulate matter measurement - Methods of characterizing and monitoring test aerosols - Optical particle counter
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
VDI 3491 Blatt 5:1980-12 Particulate matter measurement; generation of test aerosols by nebulization of dye-solutions with nozzle atomizers
EN 1822-3:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media
VDI 3491 Blatt 7:1987-12 Particulate matter measurement; generation of test aerosols; Rapaport-Weinstock generator
EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
EN 1822-4:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method)
EN 14799:2007 Air filters for general air cleaning - Terminology
VDI 3491 Blatt 13:1996-06 Particulate matter measurement - Generation of test aerosols using a vibrating-orifice generator

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.