EN 16905-1:2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Gas-fired endothermic engine driven heat pumps - Part 1: Terms and definitions
30-09-2017
08-03-2017
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Denomination
Bibliography
Index
1.1Scope of FprEN 16905 seriesThis European Standard specifies the requirements, test methods and test conditions for the rating and performance calculation of air conditioners and heat pumps using either air, water or brine as heat transfer media, with gas-fired endothermic engine driven compressors when used for space heating, cooling and refrigeration, hereafter referred to as "GEHP appliance".This European Standard only applies to appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.This European Standard only applies to appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437.This European Standard only applies to appliances having:a)gas fired endothermic engines under the control of fully automatic control systems;b)closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;c)where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;d)where the maximum operating pressure in the:1)heating water circuit (if installed) does not exceed 6 bar2)domestic hot water circuit (if installed) does not exceed 10 bar.This European Standard applies to appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by this European Standard.Packaged units, single split and multisplit systems are covered by this European Standard. Single duct and double duct units are covered by this European Standard.The above appliances can have one or more primary or secondary functions.This European Standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.In the case of packaged units (consisting of several parts), this European Standard applies only to those designed and supplied as a complete package.NOTEAll the symbols given in this text are used regardless of the language used.1.2Scope of FprEN 16905-1This part of FprEN 16905 series specifies the terms and definitions of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery.
Committee |
CEN/TC 299
|
DevelopmentNote |
Supersedes PREN 16905-1. (03/2017)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
DS EN 16905-1 : 2017 | Identical |
NS EN 16905-1 : 2017 | Identical |
DIN EN 16905-1:2015-10 (Draft) | Identical |
DIN EN 16905-1:2017-09 | Identical |
UNI EN 16905-1 : 2017 | Identical |
UNE-EN 16905-1:2017 | Identical |
PN EN 16905-1 : 2017 | Identical |
NEN EN 16905-1 : 2017 | Identical |
SN EN 16905-1 : 2017 | Identical |
NF EN 16905-1 : 2018 | Identical |
I.S. EN 16905-1:2017 | Identical |
BS EN 16905-1:2017 | Identical |
ONORM EN 16905-1 : 2017 | Identical |
I.S. EN 16905-4:2017 | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 4: TEST METHODS |
DIN EN 16905-5:2015-10 (Draft) | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 5: CALCULATION OF SEASONAL PERFORMANCES IN HEATING AND COOLING MODE |
I.S. EN 16905-5:2017 | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 5: CALCULATION OF SEASONAL PERFORMANCES IN HEATING AND COOLING MODE |
BS EN 16905-4:2017 | Gas-fired endothermic engine driven heat pumps Test methods |
I.S. EN 16905-3:2017 | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS |
DIN EN 16905-4:2015-10 (Draft) | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 4: TEST METHODS |
EN 16905-4:2017 | Gas-fired endothermic engine driven heat pumps - Part 4: Test methods |
BS EN 16905-5:2017 | Gas-fired endothermic engine driven heat pumps Calculation of seasonal performances in heating and cooling mode |
BS EN 16905-3:2017 | Gas-fired endothermic engine driven heat pumps Test conditions |
UNE-EN 16905-5:2017 | Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode |
EN 16905-3:2017 | Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions |
EN 16905-5:2017 | Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode |
DIN EN 16905-3:2015-10 (Draft) | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS |
UNE-EN 16905-3:2017 | Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions |
DIN EN 16905-3:2017-09 | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS |
EN 12309-1:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions |
EN 12309-6:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances |
EN 16905-3:2017 | Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions |
EN 12309-4:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods |
EN 16905-4:2017 | Gas-fired endothermic engine driven heat pumps - Part 4: Test methods |
EN 161:2011+A3:2013 | Automatic shut-off valves for gas burners and gas appliances |
EN 14825:2016 | Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling - Testing and rating at part load conditions and calculation of seasonal performance |
EN 16905-5:2017 | Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
EN 12309-5:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements |
EN 12309-3:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.