Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 15682-1:2013

Current

Current

The latest, up-to-date edition.

Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description

Published date

31-07-2013

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Glass products
5 Manufacturing processes
6 Heat soak process system
7 Fracture characteristics
8 Dimensions and tolerances
9 Edge work, holes, notches and cut-outs
10 Fragmentation test
11 Other physical characteristics
12 Marking
Annex A (normative) - Heat soak process system calibration test
Annex B (informative) - Curved heat soaked thermally toughened
        alkaline earth silicate safety glass
Annex C (informative) - Examples of particle count
Bibliography

This European Standard specifies the heat soak process system together with tolerances flatness, edgework, fragmentation and physical and mechanical characteristics of monolithic flat heat soaked thermally toughened alkaline earth silicate safety glass for use in buildings. Information on curved heat soak thermally toughened alkaline earth silicate safety glass is given in Annex B, but this product does not form part of this document.Other requirements, not specified in this document, can apply to heat soaked thermally toughened alkaline earth silicate safety glass which is incorporated into assemblies, e.g. laminated glass or insulating units, or undergo an additional treatment, e.g. coating. The additional requirements are specified in the appropriate product standard EN 15682-2. In this case, heat soaked thermally toughened alkaline earth silicate glass does not lose its mechanical or thermal characteristics.

Committee
CEN/TC 129
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

UNI EN 15755-1 : 2015 GLASS IN BUILDING - ADHESIVE BACKED POLYMERIC FILMED GLASS - PART 1: DEFINITIONS AND REQUIREMENTS
17/30356436 DC : 0 BS EN 16612 - GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION
UNI EN 15682-2 : 2013 GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED ALKALINE EARTH SILICATE SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY/PRODUCT STANDARD
NF EN 12758 : 2011 GLASS IN BUILDING - GLAZING AND AIRBORNE SOUND INSULATION - PRODUCT DESCRIPTIONS AND DETERMINATION OF PROPERTIES
DIN EN 16477-1:2017-07 GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 1: REQUIREMENTS
I.S. EN 16477-1:2016 GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 1: REQUIREMENTS
PREN 14449 : DRAFT 2017 GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - PRODUCT STANDARD
UNE-EN 16477-1:2017 Glass in building - Painted glass for internal use - Part 1: Requirements
BS EN 16477-1:2016 Glass in building. Painted glass for internal use Requirements
BS EN 15755-1:2014 Glass in building. Adhesive backed polymeric filmed glass Definitions and requirements
I.S. EN 15755-1:2014 GLASS IN BUILDING - ADHESIVE BACKED POLYMERIC FILMED GLASS - PART 1: DEFINITIONS AND REQUIREMENTS
UNE-EN 15755-1:2015 Glass in building - Adhesive backed polymeric filmed glass - Part 1: Definitions and requirements
EN 15755-1:2014 Glass in building - Adhesive backed polymeric filmed glass - Part 1: Definitions and requirements
EN 16477-1:2016 Glass in building - Painted glass for internal use - Part 1: Requirements
DIN EN 15755-1:2014-10 GLASS IN BUILDING - ADHESIVE BACKED POLYMERIC FILMED GLASS - PART 1: DEFINITIONS AND REQUIREMENTS
17/30351893 DC : 0 BS EN 17074 - GLASS IN BUILDING - ENVIRONMENTAL PRODUCT DECLARATION - PRODUCT CATEGORY RULES FOR FLAT GLASS PRODUCTS
PREN 16612 : DRAFT 2017 GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION
DIN EN 16477-1:2016-07 (Draft) GLASS IN BUILDING - PAINTED GLASS FOR INTERNAL USE - PART 1: REQUIREMENTS

EN 1096-1:2012 Glass in building - Coated glass - Part 1: Definitions and classification
EN 14178-1:2004 Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass
EN 1288-3:2000 Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending)
DIN 55303-7:1996-03 STATISTICAL INTERPRETATION OF DATA - PART 7: ESTIMATING AND TEST PROCEDURES FOR WEIBULL DISTRIBUTIONS WITH TWO PARAMETERS
EN 12150-1:2015 Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description
EN 15682-2:2013 Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard
EN 12600:2002 Glass in building - Pendulum test - Impact test method and classification for flat glass

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more