EN 14662-1:2005
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Ambient air quality - Standard method for measurement of benzene concentrations - Part 1 : Pumped sampling followed by thermal desorption and gas chromatography
30-11-2005
18-05-2005
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Method description
4.1 Principle
4.2 Reagents and materials
4.3 Apparatus
4.4 Sample tube conditioning
4.5 Setting of sampling flow rate
4.6 Sampling
4.7 Procedure
4.8 Calculation of mass concentration of benzene
4.9 Report
5 Determination of measurement uncertainty
5.1 Introduction
5.2 Parameters contributing to measurement uncertainty
6 Recommendations for use
Annex A (informative) Extrapolated retention volumes and safe
sampling volumes for benzene at 20 degrees C
Annex B (informative) Description of sorbent types
Annex C (informative) Guidance on sorbent selection
Annex D (informative) Guidance on sorbent use
Annex E (informative) Determination of breakthrough volume from gas
standards
Annex F (informative) Determination of breakthrough volumes from
extrapolated retention volumes
Annex G (informative) Assessment of performance indicators and
uncertainty contributions
Annex H (informative) Performance characteristics
Bibliography
This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air by pumped sampling, thermal desorption and capillary gas chromatography. This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period. This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 mg/m3 to 50 mg/m3 in an air sample typically collected over a period of 24 hours. The upper limit of the useful range is set by the sorptive capacity of the sorbent and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capacity of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sorbent. Artefacts are typically sub ng for sorbents, but higher levels of aromatic hydrocarbons have been noted in other sorbents. The detection limit will be approximately 1/10 of the lower concentration range.
Committee |
CEN/TC 264
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
BS EN 14662-1:2005 | Identical |
I.S. EN 14662-1:2005 | Identical |
PN EN 14662-1 : 2009 | Identical |
NEN EN 14662-1 : 2005 | Identical |
UNE-EN 14662-1:2006 | Identical |
NF EN 14662-1 : 2005 | Identical |
UNI EN 14662-1 : 2005 | Identical |
NS EN 14662-1 : 1ED 2005 | Identical |
SN EN 14662-1 : 2005 | Identical |
NBN EN 14662-1 : 2005 | Identical |
DS EN 14662-1 : 2005 | Identical |
ONORM EN 14662-1 : 2005 | Identical |
DIN EN 14662-1:2005-08 | Identical |
17/30362165 DC : 0 | BS EN 16402 - PAINTS AND VARNISHES - ASSESSMENT OF EMISSIONS OF SUBSTANCES FROM COATINGS INTO INDOOR AIR - SAMPLING, CONDITIONING AND TESTING |
BS EN 16516:2017 | Construction products: Assessment of release of dangerous substances. Determination of emissions into indoor air |
VDI 2283:2008-06 | Emission control - Preparation plants for ready-mix asphalt (asphalt mixing plants) |
VDI 2100 Blatt 5:2007-02 | Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Determination of volatile organic compounds, especially ozone precursors |
EN 16516:2017 | Construction products: Assessment of release of dangerous substances - Determination of emissions into indoor air |
15/30322088 DC : 0 | BS EN 16516 - CONSTRUCTION PRODUCTS - ASSESSMENT OF RELEASE OF DANGEROUS SUBSTANCES - DETERMINATION OF EMISSIONS INTO INDOOR AIR |
I.S. EN 16516:2017 | CONSTRUCTION PRODUCTS: ASSESSMENT OF RELEASE OF DANGEROUS SUBSTANCES - DETERMINATION OF EMISSIONS INTO INDOOR AIR |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 6144:2003 | Gas analysis — Preparation of calibration gas mixtures — Static volumetric method |
EN ISO 16017-1:2000 | Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000) |
ISO 5725-3:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method |
EN 1076:2009 | Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods |
ISO 16017-1:2000 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling |
ISO Guide 30:2015 | Reference materials — Selected terms and definitions |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
EN 13528-3:2003 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance |
ISO 3534-1:2006 | Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.