EN 14034-3:2006+A1:2011
Current
The latest, up-to-date edition.
Determination of explosion characteristics of dust clouds - Part 3: Determination of the lower explosion limit LEL of dust clouds
12-01-2011
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Dust sample
6 Test procedure
7 Calibration and verification
8 Safety precautions/instructions
9 Alternative test equipment/procedures
10 Test report
Annex A (normative) - Electro Pneumatic Valve
Annex B (normative) - Dust disperser with 5 mm holes
Annex C (normative) - 20 l sphere
Annex ZA (informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 94/9/EC
Bibliography
This standard describes a test method for the determination of the lower explosion limit of dust clouds in a closed vessel under defined initial conditions of pressure and temperature. This method is not suitable for use with recognised explosives, like gunpowder and dynamite, explosives which do not require oxygen for combustion, pyrophoric substances, or substances or mixtures of substances which may under some circumstances behave in a similar manner. Where any doubt exists about the existence of hazard due to explosive properties, expert advice should be sought.
Committee |
CEN/TC 305
|
DevelopmentNote |
2006 Edition Re-Issued in January 2011 & incorporates AMD 1 2011. (01/2011)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN 14034-3 : 2006 + A1 2011 | Identical |
UNE-EN 14034-3:2006 | Identical |
NBN EN 14034-3 : 2006 + A1 2011 | Identical |
NEN EN 14034-3 : 2006 + A1 2011 | Identical |
NS EN 14034-3 : 2006 + A1 2011 | Identical |
I.S. EN 14034-3:2006 | Identical |
PN EN 14034-3 : 2008 + A1 2011 | Identical |
SN EN 14034-3+A1:2011 | Identical |
UNI EN 14034-3 : 2011 | Identical |
BS EN 14034-3 : 2006 | Identical |
UNE-EN 14034-3:2006+A1:2011 | Identical |
BS EN 14034-3:2006+A1:2011 | Identical |
DIN EN 14034-3:2011-04 | Identical |
PREN 1127-1 : DRAFT 2017 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
09/30198043 DC : 0 | BS EN 1127-1 - EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
UNI EN 13237 : 2012 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
11/30239006 DC : 0 | BS EN 13237 - POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
17/30365866 DC : 0 | BS EN 1127-1 - EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
UNE-EN 1127-1:2012 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
I.S. CEN TR 15473:0 | CHARACTERIZATION OF SLUDGES - GOOD PRACTICE FOR SLUDGES DRYING |
ASTM E 1515 : 2014 : REDLINE | Standard Test Method for Minimum Explosible Concentration of Combustible Dusts |
BS EN 1127-1:2019 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
BS EN 1127-1:2011 | Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology |
NF EN 1127-1 : 2011 | EXPLOSIVES ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
I.S. EN 13237:2012 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
DIN EN 1127-1:2011-10 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
VDI 2263 Blatt 5:2014-10 | Dust fires and dust explosions - Hazards, assessment, protective measures - Explosion protection in fluidized bed dryers |
VDI 2263 Blatt 8:2008-12 | Dust fires and dust explosions - Hazards - Assessment - Protective measures - Fire and explosion protection on elevators |
VDI 2263 Blatt 7:2010-07 | Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in spraying and drying integrated equipment |
VDI 2262 Blatt 2:2012-11 | Workplace air - Reduction of exposure to air pollutants - Processing and organisation measures |
VDI 2262 Blatt 1:2013-06 | Workplace air - Reduction of exposure to air pollutants - Legal principles, terms and definitions, basic organisational measures for industrial safety and environmental protection |
VDI 2263 Blatt 6:2017-08 | Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in dust extracting installations |
PD CEN/TR 15473:2007 | Characterization of sludges. Good practice for sludges drying |
UNI EN 1127-1 : 2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
I.S. EN 1127-1:2011 | EXPLOSIVE ATMOSPHERES - EXPLOSION PREVENTION AND PROTECTION - PART 1: BASIC CONCEPTS AND METHODOLOGY |
BS EN 13237:2012 | Potentially explosive atmospheres. Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
DIN EN 13237:2013-01 | POTENTIALLY EXPLOSIVE ATMOSPHERES - TERMS AND DEFINITIONS FOR EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
CEN/TR 15473:2007 | Characterization of sludges - Good practice for sludges drying |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
UNE-EN 14034-4:2005 | Determination of explosion characteristics of dust clouds - Part 4: Determination of the limiting oxygen concentration LOC of dust clouds |
UNE-EN 14034-1:2005 | Determination of explosion characteristics of dust clouds - Part 1: Determination of the maximum explosion pressure pmax of dust clouds |
ISO 4225:1994 | Air quality General aspects Vocabulary |
EN ISO 1127:1996 | Stainless steel tubes - Dimensions, tolerances and conventional masses per unit length (ISO 1127:1992) |
ISO 6184-1:1985 | Explosion protection systems Part 1: Determination of explosion indices of combustible dusts in air |
EN 26184-1 : 1991 | EXPLOSION PROTECTION SYSTEMS - DETERMINATION OF EXPLOSION INDICES OF COMBUSTIBLE DUSTS IN AIR |
VDI 2263 Blatt 1:1990-05 | Dust fires and dust explosions; hazards, assessment, protective measures; test methods for the determination of the safety characteristic of dusts |
1994/9/EC : 1994 | DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
ISO 1127:1992 | Stainless steel tubes Dimensions, tolerances and conventional masses per unit length |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.