EN 13763-26:2004
Current
The latest, up-to-date edition.
Explosives for civil uses - Detonators and relays - Part 26: Definitions, methods, and requirements for devices and accessories for reliable and safe function of detonators and relays
18-08-2004
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements for Testing
5 Blasting machines for initiating electric detonators
5.1 Requirements for blasting machines to be verified by
visual examination of the machine, simple measurement
and reference to the manufacturer's parts list and
scale drawings
5.2 Test for insulation resistance between exposed conducting
parts
5.3 Electrical voltage withstand of insulated parts
5.4 Test to determine the output energy of the blasting machine
5.5 Test to determine the output voltage of a blasting machine
5.6 Test to check the "battery low" indication on battery operated
machines
5.7 "Ready to fire" interlock and indicator on clockwork or
capacitor blasting machines designed to produce a non-adjustable
pre-determined output firing voltage
5.8 Test to ensure the accuracy of capacitor blasting machine's
indicators
5.9 Test to check that a sequential blasting machine will not
fire if any of the initiating circuits connected to its output
terminals are open circuit or contain too much resistance
to ensure reliable initiation
5.10 Test to check that capacitor discharge machines include a safety
discharge mechanism
5.11 Test to check that, when fired, the output of a clockwork driven
blasting machine is not released until the generated voltage is
at least 90% of the maximum intended value
5.12 Ignition protection of blasting machines intended for use in
potentially explosive atmospheres
5.13 Test to check the output energy cut-off device in machines
intended for use in potentially explosive atmospheres of gas
5.14 Electromagnetic compatibility and interference tests
5.15 Ingress protection tests
5.16 Climatic and mechanical tests
5.17 Marking requirements for blasting machines
6 Blasting machine checkers
6.1 General
6.2 Requirements for blasting machines checkers to be verified
by visual examination of the checker, simple measurement and
reference to the manufacturer's parts list and scale drawings
6.3 Test for insulation resistance between exposed parts
6.4 Electrical voltage withstand of insulated parts
6.5 Test to establish the checker's ability to indicate that a
blasting machine will function correctly, also to indicate
abnormal deterioration in a blasting machine's output
6.6 Blasting machine checkers used to check the output energy cut
off time of blasting machine's intended for use in potentially
explosive atmospheres
6.7 Electromagnetic compatibility and interference test
6.8 Ingress protection
6.9 Climatic and mechanical tests
6.10 Marking requirements for blasting machine checkers
7 Field circuit testers
7.1 Requirements for field circuit testers to be verified by
visual examination of the tester, simple measurement and
reference to the manufacturer's scale drawings
7.2 Test for insulation resistance between exposed conducting
parts
7.3 Test for electrical voltage withstand of insulated parts
7.4 Tests for short circuit current limitation and maximum output
energy
7.5 Test of the accuracy of field circuit testers
7.6 Intrinsic safety of field circuit testers intended for use
in potentially explosive atmospheres
7.7 Electromagnetic compatibility and interference
7.8 Ingress protection
7.9 Climatic and mechanical tests
7.10 Marking requirements for field circuit testers
8 Shot-firing cables for use with electric blasting machines
8.1 Types of shot firing cable
8.2 Electrical resistance
8.3 Tensile tests
8.4 Shot-firing cables flexural strength tests
8.5 Shot-firing cable abrasion test
8.6 Shot-firing cable insulation test
8.7 Shot-firing cable thermostability tests
8.8 Shot-firing cables electrical insulation resistance and
insulation breakdown
8.9 Marking requirements for shot-firing cables
9 Connecting wires for use with electric blasting machines
9.1 Types of connecting wires
9.2 Requirements and tests
9.3 Marking requirements for connecting wires
10 Shock tube initiators
10.1 Requirements for shock tube initiators to be verified by
visual examination of the initiator, simple measurement
and reference to the manufacturer's scale drawings
10.2 Function test for shock tube initiators
10.3 Electromagnetic compatibility and interference
10.4 Ingress protection
10.5 Climatic and mechanical tests
10.6 Marking requirements for shock tube initiators
Annex A (normative) Electromagnetic compatibility and interference
testing as described in the relevant European Standard
Annex B (normative) Climatic and mechanical tests
Bibliography
1.1This document specifies the constructional and functional requirements and methods for testing of devices and accessories needed for the reliable and safe initiation of detonators and shock tubes, under normal working conditions. It covers the following six types of equipment:¾blasting machines for initiating electric detonators;¾blasting machine checkers;¾initiating circuit field testers;¾shot firing cables for use with electric blasting machines;¾detonator connecting wires;¾shock tube initiators for non-electric systems.1.2Equipment indented only for use indoors is excluded from the environmental testing in Annex B.1.3Blasting machines for use with electronic detonators and magnetically coupled detonators are outside the scope of this document.NOTEThis document does not meet all of the requirements of all relevant European Directives, such as the ATEX Directive 94/9/EC and the low voltage Directive 73/23/EEC. For example, EN 61010 (Safety requirements for electrical equipment for measurement, control and laboratory use) might also be relevant for some devices and accessories described in this document.
Committee |
CEN/TC 321
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 13763-26:2005 | Identical |
PN EN 13763-26 : 2006 | Identical |
NS EN 13763-26 : 1ED 2004 | Identical |
UNI EN 13763-26 : 2005 | Identical |
NBN EN 13763-26 : 2004 | Identical |
SN EN 13763-26 : 2004 | Identical |
DIN EN 13763-26:2004-11 | Identical |
BS EN 13763-26:2004 | Identical |
NF EN 13763-26 : 2005 | Identical |
NEN EN 13763-26 : 2004 | Identical |
I.S. EN 13763-26:2004 | Identical |
EN 13763-4:2003 | Explosives for civil uses - Detonators and relays - Part 4: Determination of resistance to abrasion of leading wires and shock tubes |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 13763-1:2004 | Explosives for civil uses - Detonators and relays - Part 1: Requirements |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
EN 13763-22:2003 | Explosives for civil uses - Detonators and relays - Part 22: Determination of capacitance, insulation resistance and insulation breakdown of leading wires |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 60068-2-64:2008 | ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
1973/23/EEC : 1973 | COUNCIL DIRECTIVE OF 19 FEBRUARY 1973 ON THE HARMONIZATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS |
EN 13763-5:2003 | Explosives for civil uses - Detonators and relays - Part 5: Determination of resistance to cutting damage of leading wires and shock tubes |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 13857-1:2003 | Explosives for civil uses - Part 1: Terminology |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 60068-2-32:1993 | Basic environmental testing procedures - Part 2: Tests - Test Ed: Free fall |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 13763-6:2003 | Explosives for civil uses - Detonators and relays - Part 6: Determination of resistance to cracking in low temperatures of leading wires |
1994/9/EC : 1994 | DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.