EN 13123-1:2001
Current
The latest, up-to-date edition.
Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 1: Shock tube
25-04-2001
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Classification of the level of explosion pressure
resistance (EPR)
Annex A (normative) Blast parameters and derivation
This European Standard specifies the criteria which windows, doors and shutters shall satisfy to achieve a classification when submitted to the test method described in EN 13124-1. This European Standard concerns a method of test against blast waves generated by using a shock tube facility to simulate a high explosive detonation in the order of 100 kg to 2 500 kg TNT at distances from about 35 m to 50 m.This European Standard is applicable to blast overpressure generated in a shock tube test facility used to simulate a high explosive detonation on windows, doors and shutters, complete with their frames and infills, for use in both internal and external locations in buildings. It gives no information on the explosion resistance capacity of the wall or other surrounding structure.
Committee |
CEN/TC 33
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NBN EN 13123-1 : 2001 | Identical |
UNE-EN 13123-1:2001 | Identical |
NEN EN 13123-1 : 2001 | Identical |
I.S. EN 13123-1:2001 | Identical |
BS EN 13123-1:2001 | Identical |
PN EN 13123-1 : 2002 | Identical |
SN EN 13123-1 : 2001 | Identical |
DIN EN 13123-1:2001-10 | Identical |
NS EN 13123-1 : 1ED 2001 | Identical |
NF EN 13123-1 : 2001 | Identical |
UNI EN 13123-1 : 2002 | Identical |
14/30302455 DC : 0 | BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
ISO 16933:2007 | Glass in building — Explosion-resistant security glazing — Test and classification for arena air-blast loading |
11/30245760 DC : 0 | BS EN 13541 - GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
PREN 13541 : DRAFT 2011 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
CEN/TS 14383-4:2006 | Prevention of crime - Urban planning and design - Part 4: Shops and offices |
EN 13124-1:2001 | Windows, doors and shutters - Explosion resistance - Test method - Part 1: Shock tube |
PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
DD CEN/TS 14383-3:2005 | Prevention of crime. Urban planning and building design Dwellings |
S.R. CEN/TS 14383-3:2005 | PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS |
PREN 13659 : DRAFT 2014 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
I.S. EN 13659:2015 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
I.S. EN 13541:2012 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
VDI 6203:2017-05 | Facade planning - Criteria, degree of difficulty, assessment |
S.R. CEN TR 14383-8:2009 | PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 8: PROTECTION OF BUILDINGS AND SITES AGAINST CRIMINAL ATTACKS WITH VEHICLES |
DD CEN/TS 14383-4:2006 | Prevention of crime. Urban planning and design Shops and offices |
14/30297827 DC : 0 | BS EN 14351-2 - WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
UNI CEN/TS 14383-3 : 2006 | PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS |
UNE-CEN/TR 14383-8:2011 IN | Prevention of crime - Urban planning and building design - Part 8: Protection of buildings and sites against criminal attacks with vehicles |
ISO 16934:2007 | Glass in building — Explosion-resistant security glazing — Test and classification by shock-tube loading |
UNI EN 13541 : 2012 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
11/30241851 DC : 0 | BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
CEN/TR 14383-8:2009 | Prevention of crime - Urban planning and building design - Part 8: Protection of buildings and sites against criminal attacks with vehicles |
04/30124225 DC : DRAFT OCT 2004 | ISO/DIS 16933 - GLASS IN BUILDING - EXPLOSION-RESISTANT SECURITY GLAZING - TEST AND CLASSIFICATION BY ARENA AIR-BLAST LOADING |
I.S. CEN TS 14383-4:2006 | PREVENTION OF CRIME - URBAN PLANNING AND DESIGN - PART 4: SHOPS AND OFFICES |
UNE-EN 13659:2016 | Shutters and external venetian blinds - Performance requirements including safety |
UNE-EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
BS EN 13541:2012 | Glass in building. Security glazing. Testing and classification of resistance against explosion pressure |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
EN 13659:2015 | Shutters and external venetian blinds - Performance requirements including safety |
04/30123909 DC : DRAFT OCT 2004 | ISO 16934 - GLASS IN BUILDING - EXPLOSION-RESISTANT SECURITY GLAZING - TEST AND CLASSIFICATION BY SHOCK TUBE LOADING |
UNE-CEN/TS 14383-3:2011 EX | Prevention of crime - Urban planning and building design - Part 3: Dwellings |
UNI CEN/TS 14383-4 : 2006 | PREVENTION OF CRIME - URBAN PLANNING AND DESIGN - PART 4: SHOPS AND OFFICES |
DIN EN 13541:2012-06 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
DIN EN 13659:2015-07 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
BS EN 13659:2015 | Shutters and external venetian blinds. Performance requirements including safety |
BS EN 13124-1:2001 | Windows, doors and shutters. Explosion resistance. Test method Shock tube |
CEN/TS 14383-3:2005 | Prevention of crime - Urban planning and building design - Part 3: Dwellings |
UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
EN 13124-1:2001 | Windows, doors and shutters - Explosion resistance - Test method - Part 1: Shock tube |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.