EN 129000:1993/A1:1995
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
GENERIC SPECIFICATION - FIXED RF WOUND INDUCTORS
16-09-2014
12-01-2013
Foreword
1 Scope
2 General
2.1 Related documents
2.2 Units, symbols and terminology
2.3 Preferred values
2.4 Marking
3 Quality assessment procedures
3.1 Qualification approval/Quality assessment systems
3.2 Primary stage of manufacture
3.3 Structurally similar components
3.4 Qualification approval procedures
3.5 Quality conformance inspection
3.6 Alternative test methods
3.7 Unchecked parameters
3.8 Manufacturing stages in a factory other than the
approved manufacturer's and/or outside the
geographical limits of CECC
4 Tests and measuring methods
4.1 General
4.2 Standard atmospheric conditions
4.3 Drying
4.4 Visual examination and check of dimensions
4.5 Insulation resistance
4.6 Voltage proof
4.7 Inductance
4.8 Q-factor
4.9 Self-resonant frequency
4.10 D.C. resistance
4.11 Robustness of terminations
4.12 Resistance to soldering heat
4.13 Solderability
4.14 Rapid change of temperature
4.15 Vibration
4.16 Bump
4.17 Shock
4.18 Sealing
4.19 Climatic sequence
4.20 Damp, heat, steady state
4.21 Temperature rise
4.22 Endurance
4.23 Change of inductance with current (superimposed
direct current)
4.24 Component solvent resistance
4.25 Solvent resistance of marking
4.26 Passive flammability
4.27 Active flammability
Annex
A Interpretation of sampling plans and procedures as
described in IEC 410 for use within the CECC System
electronic components
Figure
1 Suitable insulation resistance and voltage proof
test apparatus for surface mounting inductors
Applies to RF fixed wound inductors (with inductance values below 10 mH) to be used in electronic equipment. Gives terms, inspection procedures and test methods for sectional detail specifications with CECC System for electronic components.
Committee |
SR 51
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
I.S. EN 129000:1993 | Identical |
NF EN 129000 : 2014 AMD 1 2014 | Identical |
DIN EN 129000:1994-03 | Identical |
PN EN 129000 : 2002 | Identical |
NBN EN 129000 : 2008 | Identical |
NEN EN 129000 : 1995 AMD 1 1995 | Identical |
BS EN 129000:1996 | Identical |
SN EN 129000 : AMD 1 1995 | Identical |
BS EN 129102:1995 | Specification for harmonized system of quality assessment for electronic components. Blank detail specification: wirewound surface mounting inductors of assessed quality. Assessment level P |
I.S. EN 129201:1994 | BLANK DETAIL SPECIFICATION: WIREWOUND INDUCTORS WITH CERAMIC OR FERRITE CORE ASSESSMENT LEVEL E |
I.S. EN 129200:1994 | SECTIONAL SPECIFICATION: FIXED INDUCTORS WITH CERAMIC OR FERRITE CORE WOUND WITH COPPER WIRE FOR RF CIRCUITS |
I.S. EN 129202:1994 | BLANK DETAIL SPECIFICATION: WIREWOUND INDUCTORS WITH CERAMIC OR FERRITE CORE - ASSESSMENT LEVEL P |
DIN EN 129101:1994-03 | Blank detail specification: wirewound surface mounting inductors of assessed quality; assessment level E; German version EN 129101:1993 |
I.S. EN 129102:1994 | WIREWOUND SURFACE MOUNTING INDUCTORS OF ASSESSED QUALITY ASSESSMENT LEVEL P (BLANK DETAIL SPECIFICATION) |
EN 129202 : 1994 COR 1997 | BLANK DETAIL SPECIFICATION: WIREWOUND INDUCTORS WITH CERAMIC OR FERRITE CORE - ASSESSMENT LEVEL P |
EN 129201 : 1994 COR 1997 | BLANK DETAIL SPECIFICATION: WIREWOUND INDUCTORS WITH CERAMIC OR FERRITE CORE ASSESSMENT LEVEL E |
EN 129200 : 1994 AMD 1 1995 | SECTIONAL SPECIFICATION: FIXED INDUCTORS WITH CERAMIC OR FERRITE CORE WOUND WITH COPPER WIRE FOR RF CIRCUITS |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
CECC 00100 : 1988 | BASIC RULES - TO BE USED IN CONNECTION WITH THE INTERNAL REGULATIONS OF THE FEN e.V |
IEC 60286-2:2015 | Packaging of components for automatic handling - Part 2: Tape packaging of components with unidirectional leads on continuous tapes |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
CECC 00114 : 93 AMD 1 | QUALITY ASSESSMENT PROCEDURES - APPROVAL OF MANUFACTURERS AND OTHER ORGANIZATIONS |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60062:2016 | Marking codes for resistors and capacitors |
IEC 60063:2015 | Preferred number series for resistors and capacitors |
ISO 497:1973 | Guide to the choice of series of preferred numbers and of series containing more rounded values of preferred numbers |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60286-3:2013 | Packaging of components for automatic handling - Part 3: Packaging of surface mount components on continuous tapes |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60286-1:2017 | Packaging of components for automatic handling - Part 1: Tape packaging of components with axial leads on continuous tapes |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.