Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 12766-2:2001

Current

Current

The latest, up-to-date edition.

Petroleum products and used oils - Determination of PCBs and related products - Part 2: Calculation of polychlorinated biphenyl (PCB) content

Published date

18-07-2001

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative References
3 Terms and definitions
4 Calculation methods
5 Calculation of Precision Values
6 Test Report
ANNEX A (normative) Test mixture
Annex B (normative) Precision values
Bibliography

This standard specifies two calculation procedures ("method A" and "method B") for PCB content. The basis for this quantification is taken from the chromatographic results of EN 12766-1:2000 in which all necessary experimental procedures are described for the specific analysis of unused, used and treated (e.g. dechlorinated) petroleum products including synthetic lubricating oils and mixtures of vegetable oils. The method is also applicable to petroleum products and synthetic lubricating oils suitably recovered from other materials, e.g. from waste materials. Both methods have different strengths and weaknesses which are described in the next paragraphs and which must be considered before use in a specific application. Proper application of either method A or method B needs to be carefully considered before use in a specific application.Using method A, special care needs to be exercised to avoid interferences from non PCB substances which may occur in the chromatogram. Therefore, method A can be used predominantly for the analysis of used and unused insulating oils. It is recommended not to use calculation method A without special precautions for other than above-mentioned products. Calculation method A can produce two alternative sets of results, ("All Probables" and "All Possibles"). Therefore, care needs to be taken in order to interpret these results in the correct manner.Method B uses as intermediate result the sum of six congeners, which belong to the most abundant in almost all technical PCB materials, thereby minimizing potential interferences from other (coeluting) non PCB substances. To obtain the PCB content, the intermediate sum from six congeners needs to be multiplied by a multiplication factor. Calculation Method B can be used predominantly for the analysis of liquids from used and waste materials of unknown origin and for samples with low PCB contents.

Committee
CEN/TC 19
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

BS 2000-462.3(2004) : 2004 PETROLEUM PRODUCTS AND USED OILS - DETERMINATION OF PCBS AND RELATED PRODUCTS - PART 3: DETERMINATION AND QUANTIFICATION OF POLYCHLORINATED TERPHENYLS (PCT) AND POLYCHLORINATED BENZYL TOLUENES (PCBT) CONTENT BY GAS CHROMATOGRAPHY (GC) USING AN ELECTRON CAPTURE DETECTOR (ECD)
BS EN 15308:2016 Characterization of waste. Determination of selected polychlorinated biphenyls (PCB) in solid waste by gas chromatography with electron capture or mass spectrometric detection
I.S. EN 12766-3:2005 PETROLEUM PRODUCTS AND USED OILS - DETERMINATION OF PCBS AND RELATED PRODUCTS - PART 3: DETERMINATION AND QUANTIFICATION OF POLYCHLORINATED TERPHENYLS (PCT) AND POLYCHLORINATED BENZYL TOLUENES (PCBT) CONTENT BY GAS CHROMATOGRAPHY (GC) USING AN ELECTRON CAPTURE DETECTOR (ECD)
EN 1948-4:2010+A1:2013 Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 4: Sampling and analysis of dioxin-like PCBs
I.S. EN 1948-4:2010 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF PCDDS/PCDFS AND DIOXIN-LIKE PCBS - PART 4: SAMPLING AND ANALYSIS OF DIOXIN-LIKE PCBS
BS EN 12766-3:2004 Petroleum products and used oils. Determination of PCBs and related products Determination and quantification of polychlorinated terphenyls (PCT) and polychlorinated benzyl toluenes (PCBT) content by gas chromatography (GC) using an electron capture detector (ECD)
EN 15308:2016 Characterization of waste - Determination of selected polychlorinated biphenyls (PCB) in solid waste by gas chromatography with electron capture or mass spectrometric detection
VDI 3957 Blatt 2:2016-03 Biological measuring techniques for the determination and assessment of effects of air pollutants on plants (biomonitoring) - Method of the standardised grass exposure
UNE-EN 15308:2017 Characterization of waste - Determination of selected polychlorinated biphenyls (PCB) in solid waste by gas chromatography with electron capture or mass spectrometric detection
DIN EN 1948-4:2014-03 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF PCDDS/PCDFS AND DIOXIN-LIKE PCBS - PART 4: SAMPLING AND ANALYSIS OF DIOXIN-LIKE PCBS
06/30159746 DC : 0 BS EN 50503 - FLUIDS FOR ELECTROTECHNICAL APPLICATIONS - STANDARD FOR THE INVENTORY CONTROL, MANAGEMENT, DECONTAMINATION AND/OR DISPOSAL OF ELECTRICAL EQUIPMENT AND INSULATING LIQUIDS CONTAINING PCBS
01/124547 DC : DRAFT JAN 2002 PREN 12766-3 - PETROLEUM PRODUCTS AND USED OILS - DETERMINATION OF PCBS AND RELATED PRODUCTS - PART 3: DETERMINATION AND QUANTIFICATION OF POLYCHLORINATED TERPHENYLS (PCT) AND POLYCHLORINATED BENZYL TOLUENES (PCBT) CONTENT BY GAS CHROMATOGRAPHY (GC) USING AN ELECTRON CAPTURE DETECTOR (ECD)
PREN 15308 : DRAFT 2015 CHARACTERIZATION OF WASTE - DETERMINATION OF SELECTED POLYCHLORINATED BIPHENYLS (PCB) IN SOLID WASTE BY GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE OR MASS SPECTROMETRIC DETECTION
17/30364002 DC : 0 BS EN 16167 - SOIL, TREATED BIOWASTE AND SLUDGE - DETERMINATION OF POLYCHLORINATED BIPHENYLS (PCB) BY GAS CHROMATOGRAPHY WITH MASS SELECTIVE DETECTION (GC-MS) AND GAS CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION (GC-ECD)
UNE-EN 1948-4:2011 Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 4: Sampling and analysis of dioxin-like PCBs
PREN 16167 : DRAFT 2017 SOIL, TREATED BIOWASTE AND SLUDGE - DETERMINATION OF POLYCHLORINATED BIPHENYLS (PCB) BY GAS CHROMATOGRAPHY WITH MASS SELECTIVE DETECTION (GC-MS) AND GAS CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION (GC-ECD)
I.S. EN 15308:2016 CHARACTERIZATION OF WASTE - DETERMINATION OF SELECTED POLYCHLORINATED BIPHENYLS (PCB) IN SOLID WASTE BY GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE OR MASS SPECTROMETRIC DETECTION
BS EN 1948-4 : 2010 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF PCDDS/PCDFS AND DIOXIN-LIKE PCBS - PART 4: SAMPLING AND ANALYSIS OF DIOXIN-LIKE PCBS
15/30330799 DC : 0 BS EN 15308 - CHARACTERIZATION OF WASTE - DETERMINATION OF SELECTED POLYCHLORINATED BIPHENYLS (PCB) IN SOLID WASTE BY GAS CHROMATOGRAPHY WITH ELECTRON CAPTURE OR MASS SPECTROMETRIC DETECTION
CLC/TR 50503:2010 Guidelines for the inventory control, management, decontamination and/or disposal of electrical equipment and insulating liquids containing PCBs
S.R. CLC/TR 50503:2010 GUIDELINES FOR THE INVENTORY CONTROL, MANAGEMENT, DECONTAMINATION AND/OR DISPOSAL OF ELECTRICAL EQUIPMENT AND INSULATING LIQUIDS CONTAINING PCBS
PREN 12766-3 : DRAFT 2001 PETROLEUM PRODUCTS AND USED OILS - DETERMINATION OF PCBS AND RELATED PRODUCTS - PART 3: DETERMINATION AND QUANTIFICATION OF POLYCHLORINATED TERPHENYLS (PCT) AND POLYCHLORINATED BENZYL TOLUENES (PCBT) CONTENT BY GAS CHROMATOGRAPHY (GC) USING AN ELECTRON CAPTURE DETECTOR (ECD)
UNI EN 1948-4 : 2014 STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF PCDDS/PCDFS AND DIOXIN-LIKE PCBS - PART 4: SAMPLING AND ANALYSIS OF DIOXIN-LIKE PCBS
DIN EN 12766-3:2005-02 Petroleum products and used oils - Determination of PCBs and related products - Part 3: Determination and quantification of polychlorinated terphenyls (PCT) and polychlorinated benzyl toluenes (PCBT) content by gas chromatography (GC) using an electron capture detector (ECD)

EN 12766-1:2000 Petroleum products and used oils - Determination of PCBs and related products - Part 1: Separation and determination of selected PCB congeners by gas chromatography (GC) using an electron capture detector (ECD)
EN 61619:1997 Insulating liquids - Contamination by polychlorinated biphenyls (PCBs) - Method of determination by capillary column gas chromatography
ISO 4259:2006 Petroleum products Determination and application of precision data in relation to methods of test
IEC 61619:1997 Insulating liquids - Contamination by polychlorinated biphenyls (PCBs) - Method of determination by capillary column gas chromatography
EN ISO 4259:2006 Petroleum products - Determination and application of precision data in relation to methods of test (ISO 4259:2006)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.