This standard specifies principles and testing procedures for determining, by means of the guarded hot plate or heat flow meter methods, the thermal resistance of test specimens having a thermal resistance of not less than 0,5 m2 K/W.
Committee |
CEN/TC 89
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN 12667 : 2001 | Identical |
NEN EN 12667 : 2001 | Identical |
UNE-EN 12667:2002 | Identical |
UNI EN 12667 : 2002 | Identical |
NS EN 12667 : 1ED 2001 | Identical |
PN EN 12667 : 2002 | Identical |
BS EN 12667:2001 | Identical |
I.S. EN 12667:2001 | Identical |
NBN EN 12667 : 2001 | Identical |
SN EN 12667 : 2001 | Identical |
DIN EN 12667:2001-05 | Identical |
15/30315069 DC : DRAFT MAY 2015 | BS EN 14313 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
DIN EN 15632-1:2015-03 | District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods (includes Amendment A1:2014) |
BS EN 15501:2013 | Thermal insulation products for building equipment and industrial installations. Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products. Specification |
DIN EN 16855-1 E : 2017 | WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 1: PREFABRICATED COLD ROOM KITS |
PD CEN/TS 15548-1:2014 | Thermal insulation products for building equipment and industrial installations. Determination of thermal resistance by means of the guarded hot plate method Measurements at elevated temperatures from 100 °C to 850 °C |
I.S. EN ISO 23993:2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF DESIGN THERMAL CONDUCTIVITY |
I.S. EN 12104:2000 | RESILIENT FLOOR COVERINGS - CORK FLOOR TILES - SPECIFICATION |
09/30207822 DC : 0 | BS EN 15600-1 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 14313 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
UNE-EN 14306:2017 | Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products - Specification |
DIN EN 15600-1:2010-12 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 1: Specification for bonded and loose-fill products before installation |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
15/30315078 DC : DRAFT MAY 2015 | BS EN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
10/30213965 DC : 0 | BS EN 13164 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
10/30212171 DC : 0 | BS EN 15037-5 - PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 5: LIGHTWEIGHT BLOCKS FOR SIMPLE FORMWORK |
07/30166420 DC : DRAFT AUG 2007 | BS EN 1520 - PREFABRICATED REINFORCED COMPONENTS OF LIGHTWEIGHT AGGREGATE CONCRETE WITH OPEN STRUCTURE |
08/30169531 DC : DRAFT APR 2008 | BS EN 13162 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
05/30136503 DC : 0 | PREN 14309 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
PREN 16855 : DRAFT 2015 | WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 1: PREFABRICATED COLD ROOM KITS |
PREN 12104 : DRAFT 2017 | RESILIENT FLOOR COVERINGS - CORK FLOOR TILES - SPECIFICATION |
PREN 14309 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
09/30209668 DC : 0 | BS EN 16025-1 - THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
05/30134359 DC : DRAFT MAY 2005 | EN 15101-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL CELLULOSE PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
DIN EN 14303:2016-08 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
I.S. EN 14320-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
DD CEN/TS 15398:2006 | Resilient, textile and laminate floor coverings. Floor covering standard symbols |
05/30136556 DC : 0 | PREN 14313 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATION - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
DIN EN 14306:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
DIN EN 14313:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
BS EN 14307:2015 | Thermal insulation products for building equipment and industrial installations. Factory made extruded polystyrene foam (XPS) products. Specification |
DIN EN 16069:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
NF EN 14064-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 13169 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
DIN EN 14304:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
I.S. EN 15037-4:2010 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 4: EXPANDED POLYSTYRENE BLOCKS |
I.S. EN 14304:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
I.S. EN 15101-1:2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
I.S. EN 16012:2012 | THERMAL INSULATION FOR BUILDINGS - REFLECTIVE INSULATION PRODUCTS - DETERMINATION OF THE DECLARED THERMAL PERFORMANCE |
S.R. CEN/TS 15679:2007 | THERMAL MODIFIED TIMBER - DEFINITIONS AND CHARACTERISTICS |
UNI EN 15037-4 : 2013 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 4: EXPANDED POLYSTYRENE BLOCKS |
EN 15102:2007+A1:2011 | Decorative wall coverings - Roll and panel form |
UNI EN 15101-1 : 2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
UNE-EN ISO 23993:2012 | Thermal insulation products for building equipment and industrial installations - Determination of design thermal conductivity (ISO 23993:2008, Corrected version 2009-10-01) |
UNE-EN 14318-1:2013 | Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
16/30325907 DC : 0 | BS EN 15102 - DECORATIVE WALLCOVERINGS - ROLL FORM |
EN 15101-1:2013 | Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation |
PREN 16809-1 : DRAFT 2014 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED PRODUCTS FROM LOOSE-FILL EXPANDED POLYSTYRENE (EPS) BEADS AND BONDED EXPANDED POLYSTYRENE BEADS - PART 1: SPECIFICATION FOR THE BONDED AND LOOSE FILLED PRODUCTS BEFORE INSTALLATION |
UNE-EN ISO 10077-1:2010 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General |
DIN EN 13169:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
DIN EN ISO 10456:2010-05 | Building materials and products - Hygrothermal properties - Tabulated design values and procedures for determining declared and design thermal values (ISO 10456:2007 + Cor. 1:2009); German version EN ISO 10456:2007 + AC:2009 |
BS EN 14620-4:2006 | Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0°C and -165°C Insulation components |
BS EN 14933:2007 | Thermal insulation and light weight fill products for civil engineering applications. Factory made products of expanded polystyrene (EPS). Specification |
BS EN 13168 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
BS EN 13403:2003 | Ventilation for buildings. Non metallic ducts. Ductwork made from insulation ductboards |
BS EN 13164 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
BS EN 1946-5:2000 | Thermal performance of building products and components. Specific criteria for the assessment of laboratories measuring heat transfer properties Measurements by pipe test methods |
I.S. EN 13168:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
I.S. EN 13165:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
CEN/TS 16354:2013 | Laminate floor coverings - Underlays - Specification, requirements and test methods |
DIN EN 14316-1:2004-11 | Thermal insulation products for buildings - In-situ thermal insulation formed from expanded perlite (EP) products - Part 1: Specification for bonded and loose-fill products before installation; German version EN 14316-1:2004 |
DIN EN 14041:2008-05 | RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
DIN EN 14933:2007-12 | Thermal insulation and light weigth fill products for civil engineering applications - Factory made products of expanded polystyrene (EPS) - Specification |
DIN EN 14317-1:2004-11 | Thermal insulation products for buildings - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 1: Specification for bonded and loose-fill products before installation; German version EN 14317-1:2004 |
EN 12104:2000 | Resilient floor coverings - Cork floor tiles - Specification |
EN 13166:2012+A2:2016 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
CEN/TS 15679:2007 | Thermal Modified Timber - Definitions and characteristics |
EN 12664:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance |
EN 13162:2012+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
EN 13163:2012+A2:2016 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
EN 13055-2:2004 | Lightweight aggregates - Part 2: Lightweight aggregates for bituminous mixtures and surface treatments and for unbound and bound applications |
EN 12939:2000 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Thick products of high and medium thermal resistance |
EN 13213:2001 | Hollow floors |
I.S. EN 15026:2007 | HYGROTHERMAL PERFORMANCE OF BUILDING COMPONENTS AND BUILDING ELEMENTS - ASSESSMENT OF MOISTURE TRANSFER BY NUMERICAL SIMULATION |
I.S. CEN TS 15398:2006 | RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - FLOOR COVERING STANDARD SYMBOLS |
09/30198700 DC : 0 | BS EN 15037-4 - PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 4: EXPANDED POLYSTYRENE BLOCKS |
15/30315087 DC : DRAFT MAY 2015 | BS EN 14314 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
08/30169546 DC : DRAFT APR 2008 | BS EN 13167 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
I.S. EN 16025-1:2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
07/30160790 DC : 0 | BS EN 15632-1 - DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS |
DIN EN 14320-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
I.S. EN 13055-2:2004 | LIGHTWEIGHT AGGREGATES - PART 2: LIGHTWEIGHT AGGREGATES FOR BITUMINOUS MIXTURES AND SURFACE TREATMENTS AND FOR UNBOUND AND BOUND APPLICATIONS |
DIN EN 16012:2015-05 | Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance (includes Amendment A1:2015) |
UNI EN ISO 23993 : 2011 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF DESIGN THERMAL CONDUCTIVITY |
DIN EN 14307:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
PREN 14064-1 : DRAFT 2016 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
15/30315081 DC : DRAFT MAY 2015 | BS EN 14308 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
BS EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products Specification for the rigid foam spray system before installation |
10/30213980 DC : 0 | BS EN 13169 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
I.S. EN 14319-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
16/30339855 DC : 0 | BS EN 14041 - RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
DIN EN 16025-1:2013-07 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
05/30136516 DC : 0 | PREN 14308 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
12/30256925 DC : 0 | BS EN 13055 - LIGHTWEIGHT AGGREGATES FOR CONCRETE, MORTAR, GROUT, BITUMINOUS MIXTURES, SURFACE TREATMENTS AND FOR UNBOUND AND BOUND APPLICATIONS |
10/30213986 DC : 0 | BS EN 13171 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
BS EN 16025-1:2013 | Thermal and/or sound insulating products in building construction. Bound EPS ballastings Requirements for factory premixed EPS dry plaster |
08/30169559 DC : DRAFT APR 2008 | BS EN 13171 - THERMAL INSULATING PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
PREN 13165 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
PREN 15501 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
DD CEN/TS 15548-1:2011 | Thermal insulation products for building equipment and industrial installations. Determination of thermal resistance by means of the guarded hot plate method Measurements at elevated temperatures from 100 °C to 850 °C |
10/30213971 DC : 0 | BS EN 13166 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
BS EN 14303 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
11/30241970 DC : 0 | DD CEN/TS 15548 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF THERMAL RESISTANCE BY MEANS OF THE GUARDED HOT PLATE METHOD - PART 1: MEASUREMENTS AT ELEVATED TEMPERATURES FROM 100 DEGREES C TO 850 DEGREES C |
PREN 15600-1 : DRAFT 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 13164 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
08/30169552 DC : DRAFT APR 2008 | BS EN 13169 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED PERLITE (EPB) - SPECIFICATION |
01/101336 DC : DRAFT JAN 2001 | PREN 13964 - SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
I.S. EN 14305:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
PREN 14314 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
05/30136550 DC : 0 | PREN 14314 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
PRCEN/TS 15548-1 : DRAFT 2011 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF THERMAL RESISTANCE BY MEANS OF THE GUARDED HOT PLATE METHOD - PART 1: MEASUREMENTS AT ELEVATED TEMPERATURES FROM 100 DEGREES C TO 850 DEGREES C |
PREN 14304 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
I.S. EN 14306:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
UNE-EN 14309:2017 | Thermal insulation products for building equipment and industrial installations - Factory made products of expanded polystyrene (EPS) - Specification |
DIN EN 14308:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
I.S. EN 13055:2016 | LIGHTWEIGHT AGGREGATES |
DIN EN 14309:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
PREN 14305 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 14304 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
BS EN 15632-1 : 2009 | DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS |
I.S. EN 14303:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
PREN 16354 : DRAFT 2016 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
I.S. EN 15600-1:2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 14306 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
UNI EN 14064-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
DIN EN 15101-1:2013-12 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
16/30333219 DC : 0 | BS EN 16354 - LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
15/30301583 DC : 0 | BS EN 16863 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE REFLECTIVE INSULATION PRODUCTS (RI) - SPECIFICATION |
12/30268937 DC : 0 | BS EN 16491 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE COMPOSITE PRODUCTS - SPECIFICATION |
PREN 14933 : DRAFT 2004 | LIGHT WEIGHT FILL AND INSULATION PRODUCTS FOR CIVIL ENGINEERING APPLICATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
UNE-EN 16012:2013 | Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance |
DIN EN 13170:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
DIN EN 13164:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
DIN EN 13165:2016-09 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
DIN EN 13166:2016-09 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
DIN EN 13168:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
DIN EN 1520:2011-06 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non-structural reinforcement |
DIN EN 13162:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
BS EN 13055-2:2004 | Lightweight aggregates Lightweight aggregates for bituminous mixtures and surface treatments and for unbound and bound applications |
ISO 10456:2007 | Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
BS EN 14317-1:2004 | Thermal insulation products for buildings. In-situ thermal insulation formed from exfoliated vermiculite (EV) products Specification for bonded and loose-fill products before installation |
BS EN 14316-1:2004 | Thermal insulation products for buildings. In-situ thermal insulation formed from expanded perlite (EP) products Specification for bonded and loose-fill products before installation |
BS EN 13169 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
I.S. EN ISO 10456:2007 | BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES AND PROCEDURES FOR DETERMINING DECLARED AND DESIGN THERMAL VALUES |
DIN EN 13163:2017-02 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
I.S. EN 13164:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
I.S. EN 13163:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
I.S. EN 13166:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
I.S. EN 1520:2011 | PREFABRICATED REINFORCED COMPONENTS OF LIGHTWEIGHT AGGREGATE CONCRETE WITH OPEN STRUCTURE WITH STRUCTURAL OR NON-STRUCTURAL REINFORCEMENT |
I.S. EN 13167:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
I.S. EN 13171:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
I.S. EN 13169:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED PERLITE BOARD (EPB) PRODUCTS - SPECIFICATION |
I.S. EN 13162:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
I.S. EN 13170:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
I.S. EN 13950:2014 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
I.S. EN 13964:2014 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
DIN EN 16855-1:2017-05 | WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 1: PREFABRICATED COLD ROOM KITS |
DIN EN 15037-4:2013-08 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 4: EXPANDED POLYSTYRENE BLOCKS |
15/30315075 DC : DRAFT MAY 2015 | BS EN 14305 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
I.S. EN 15102:2007 | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
BS EN 13055:2016 | Lightweight aggregates |
02/701820 DC : 0 | BS EN 14303 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
BS EN 15599-1:2010 | Thermal insulation products for building equipment and industrial installations. In-situ thermal insulation formed from expanded perlite (EP) products Specification for bonded and loose-fill products before installation |
15/30320130 DC : 0 | BS EN 16855 - WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 1: PREFABRICATED COLD ROOM KITS |
00/108536 DC : 0 | PREN 14064-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
11/30244187 DC : 0 | BS EN 14041 - RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
UNI EN 15037-5 : 2013 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 5: LIGHTWEIGHT BLOCKS FOR SIMPLE FORMWORK |
13/30258117 DC : 0 | BS EN 15101-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
BS EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam spray system before installation |
DIN EN 15599-1:2010-12 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from expanded perlite (EP) products - Part 1: Specification for bonded and loose-fill products before installation |
PREN 13167 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
UNI EN 15599-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNI EN 14320-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
UNE-EN 14305:2017 | Thermal insulation products for building equipment and industrial installations - Factory made cellular glass (CG) products - Specification |
12/30270374 DC : 0 | BS EN 15501 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
I.S. EN 14309:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
15/30315072 DC : DRAFT MAY 2015 | BS EN 14306 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
08/30169549 DC : DRAFT APR 2008 | BS EN 13168 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
10/30213977 DC : 0 | BS EN 13168 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
DIN EN 14315-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
04/30126133 DC : DRAFT NOV 2004 | EN 15100-1 - THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED UREAFORMALDEHYDE FOAM (UF) PRODUCTS - PART 1: SPECIFICATION FOR THE FOAM SYSTEM BEFORE INSTALLATION |
04/30113509 DC : DRAFT MAY 2004 | BS EN 14934 - THERMAL INSULATION OF ROAD AND RAILWAYS AND EMBANKMENT FILLING - FACTORY MADE PRODUCTS OF EXTRUDED POLYSTYRENE FOAM (XPS) - SPECIFICATION |
BS EN 14314:2015 | Thermal insulation products for building equipment and industrial installations. Factory made phenolic foam (PF) products. Specification |
UNI CEN/TS 16354 : 2014 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
10/30213974 DC : 0 | BS EN 13167 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
UNE-EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam spray system before installation |
UNE-EN 14313:2017 | Thermal insulation products for building equipment and industrial installations - Factory made polyethylene foam (PEF) products - Specification |
PREN 13162 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
PREN 14308 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
DIN EN 14314:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
DIN EN 15501:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
BS EN 14064-1:2010 | Thermal insulation products for buildings. In-situ formed loose-fill mineral wool (MW) products Specification for the loose-fill products before installation |
BS EN 14309:2015 | Thermal insulation products for building equipment and industrial installations. Factory made products of expanded polystyrene (EPS). Specification |
I.S. EN 14041:2018 | RESILIENT, TEXTILE, LAMINATE AND MODULAR MULTILAYER FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
UNE-CEN/TS 15679:2009 EX | Thermal Modified Timber - Definitions and characteristics |
PREN 15599-1 : DRAFT 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
I.S. EN 16855-1:2017 | WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 1: PREFABRICATED COLD ROOM KITS |
UNI EN 16025-1 : 2013 | THERMAL AND/OR SOUND INSULATING PRODUCTS IN BUILDING CONSTRUCTION - BOUND EPS BALLASTINGS - PART 1: REQUIREMENTS FOR FACTORY PREMIXED EPS DRY PLASTER |
UNI EN 14319-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
PREN 14307 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
PREN 13171 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
PREN 13950 : DRAFT 2011 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNI EN 15026 : 2008 | HYGROTHERMAL PERFORMANCE OF BUILDING COMPONENTS AND BUILDING ELEMENTS - ASSESSMENT OF MOISTURE TRANSFER BY NUMERICAL SIMULATION |
ISO 9149:2010 | Cork wallcoverings in rolls Specifications |
DIN EN 13171:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
DIN EN 13167:2015-04 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
DIN EN 13163:2016-08 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
DIN EN 13964:2014-08 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
DIN EN 13950:2014-09 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNE-EN ISO 10456:2012 | Building materials and products - Hygrothermal properties -Tabulated design values and procedures for determining declared and design thermal values (ISO 10456:2007) |
BS EN 1520:2011 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non-structural reinforcement |
BS EN 12939:2001 | Thermal performance of building materials and products. Determination of thermal resistance by means of guarded hot plate and heat flow meter methods. Thick products of high and medium thermal resistance |
ISO 23993:2008 | Thermal insulation products for building equipment and industrial installations — Determination of design thermal conductivity |
BS EN 13213:2001 | Hollow floors |
BS EN 12104:2000 | Resilient floor coverings. Cork floor tiles. Specification |
EN 14064-1:2010 | Thermal insulation products for buildings - In-situ formed loose-fill mineral wool (MW) products - Part 1: Specification for the loose-fill products before installation |
EN 13964:2014 | Suspended ceilings - Requirements and test methods |
UNI EN 14063-1 : 2005 | THERMAL INSULATION MATERIALS AND PRODUCTS - IN-SITU FORMED EXPANDED CLAY LIGHTWEIGHT AGGREGATE PRODUCTS (LWA) - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNI EN 1520 : 2011 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non- structural reinforcement |
UNI EN 13964 : 2014 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
EN 1946-5:2000 | Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 5: Measurements by pipe test methods |
UNI EN ISO 10456 : 2008 | BUILDING MATERIALS AND PRODUCTS - HYGROTHERMAL PROPERTIES - TABULATED DESIGN VALUES AND PROCEDURES FOR DETERMINING DECLARED AND DESIGN THERMAL VALUES |
UNI EN 13950 : 2014 | GYPSUM BOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
UNI EN 13403 : 2004 | VENTILATION FOR BUILDINGS - NON- METALLIC DUCTS - DUCTWORK MADE FROM INSULATION DUCTBOARDS |
DIN EN 14041:2016-07 (Draft) | RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
10/30213983 DC : 0 | BS EN 13170 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
UNI CEN/TS 15548-1 : 2014 | Thermal insulation products for building equipment and industrial installations - Determination of thermal resistance by means of the guarded hot plate method - Part 1: Measurements at elevated temperatures from 100 °C to 850 °C<br> |
16/30330679 DC : DRAFT MAR 2016 | BS EN 16977 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CALCIUM SILICATE (CS) PRODUCTS - SPECIFICATION |
I.S. EN 14314:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
BS EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products Specification for the rigid foam dispensed system before installation |
08/30169537 DC : DRAFT APR 2008 | BS EN 13164 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXTRUDED POLYSTYRENE FOAM (XPS) - SPECIFICATION |
15/30315084 DC : DRAFT MAY 2015 | BS EN 14309 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
BS EN 16069 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
15/30315090 DC : DRAFT MAY 2015 | BS EN 14304 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) PRODUCTS - SPECIFICATION |
PREN 13170 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
05/30136552 DC : 0 | PREN 14304 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE FLEXIBLE ELASTOMERIC FOAM (FEF) - SPECIFICATION |
PREN 14303 : DRAFT 2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
UNI EN 14315-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
ISO 3813:2004 | Resilient floor coverings Cork floor tiles Specification |
UNI EN 14318-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
PREN 13168 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD WOOL (WW) PRODUCTS - SPECIFICATION |
06/30153920 DC : 0 | BS EN 15548-1 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF THERMAL RESISTANCE BY MEANS OF THE GUARDED HOT PLATE METHOD - PART 1: MEASUREMENTS AT ELEVATED TEMPERATURES FROM 100 DEGREE C TO 850 DEGREE C |
11/30251985 DC : 0 | BS EN 13950 - GYPSUM PLASTERBOARD THERMAL/ACOUSTIC INSULATION COMPOSITE PANELS - DEFINITIONS, REQUIREMENTS AND TEST METHODS |
BS EN 15037-5:2013 | Precast concrete products. Beam-and-block floor systems Lightweight blocks for simple formwork |
DIN EN 16855-1:2015-06 (Draft) | WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 1: PREFABRICATED COLD ROOM KITS |
BS EN 14308:2015 | Thermal insulation products for building equipment and industrial installations. Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products. Specification |
BS EN 14306:2015 | Thermal insulation products for building equipment and industrial installations. Factory made calcium silicate (CS) products. Specification |
08/30193356 DC : DRAFT DEC 2008 | BS ISO 8724 - CORK DECORATIVE PANELS - SPECIFICATION |
I.S. EN ISO 10077-1:2017 | THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 1: GENERAL (ISO 10077-1:2017) |
08/30169543 DC : DRAFT APR 2008 | BS EN 13166 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF PHENOLIC FOAM (PF) - SPECIFICATION |
08/30169540 DC : DRAFT APR 2008 | BS EN 13165 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) PRODUCTS - SPECIFICATION |
DD CEN/TS 15679:2007 | Thermal modified timber. Definitions and characteristics |
S.R. CEN/TS 15548-1:2014 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF THERMAL RESISTANCE BY MEANS OF THE GUARDED HOT PLATE METHOD - PART 1: MEASUREMENTS AT ELEVATED TEMPERATURES FROM 100 DEGREES C TO 850 DEGREES C |
BS EN 14318-1:2013 | Thermal insulating products for buildings. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam dispensed system before installation |
13/30217369 DC : 0 | BS EN 13964 - SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
09/30207815 DC : 0 | BS EN 15599-1 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
08/30169534 DC : DRAFT APR 2008 | BS EN 13163 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
UNI CEN/TS 15679 : 2008 | THERMAL MODIFIED TIMBER - DEFINITIONS AND CHARACTERISTICS |
DIN EN ISO 23993:2011-02 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF DESIGN THERMAL CONDUCTIVITY |
UNE-EN 15632-1:2010 | District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods |
UNE-EN 14307:2017 | Thermal insulation products for building equipment and industrial installations - Factory made extruded polystyrene foam (XPS) products - Specification |
02/124567 DC : DRAFT DEC 2002 | BS ISO 3813 - RESILIENT FLOOR COVERINGS - CORK FLOOR TILES - SPECIFICATION |
I.S. EN 16069:2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
10/30213959 DC : 0 | BS EN 13162 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
07/30166918 DC : DRAFT AUG 2007 | BS EN 14064-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
03/105151 DC : DRAFT MAR 2003 | PREN 14620-4 - DESIGN AND MANUFACTURE OF SITE BUILT, VERTICAL, CYLINDRICAL, FLAT-BOTTOMED STEEL TANKS FOR THE STORAGE OF REFRIGERATED, LIQUEFIED GASES WITH OPERATING TEMPERATURES BETWEEN -5 DEGREES C AND -165 DEGREES C - PART 4: INSULATION COMPONENTS |
BS EN ISO 23993:2010 | Thermal insulation products for building equipment and industrial installations. Determination of design thermal conductivity |
15/30315096 DC : DRAFT MAY 2015 | BS EN 15501 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
DIN EN 15037-5:2013-08 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 5: LIGHTWEIGHT BLOCKS FOR SIMPLE FORMWORK |
NF EN 15600-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
UNE-EN 14308:2017 | Thermal insulation products for building equipment and industrial installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products - Specification |
NF EN 15599-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
PREN 15101-1 : DRAFT 2013 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE FILL CELLULOSE (LFCI) PRODUCTS - PART 1: SPECIFICATION FOR THE PRODUCTS BEFORE INSTALLATION |
BS EN 14305:2015 | Thermal insulation products for building equipment and industrial installations. Factory made cellular glass (CG) products. Specification |
PREN 15102 : DRAFT 2016 | DECORATIVE WALLCOVERINGS - ROLL FORM |
I.S. EN 15037-5:2013 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 5: LIGHTWEIGHT BLOCKS FOR SIMPLE FORMWORK |
UNI EN 15102 : 2011 | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
17/30359856 DC : 0 | BS EN 12104 - RESILIENT FLOOR COVERINGS - CORK FLOOR TILES - SPECIFICATION |
PREN 16491 : DRAFT 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE COMPOSITE PRODUCTS - SPECIFICATION |
PREN 14041 : DRAFT 2016 | RESILIENT, TEXTILE AND LAMINATE FLOOR COVERINGS - ESSENTIAL CHARACTERISTICS |
I.S. EN 14308:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE RIGID POLYURETHANE FOAM (PUR) AND POLYISOCYANURATE FOAM (PIR) PRODUCTS - SPECIFICATION |
I.S. EN 14313:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
DIN EN 14063-1:2016-10 (Draft) | Thermal insulation products for buildings - In-situ formed expanded clay lightweight aggregate products - Part 1: Specification for the loose-fill products before installation; German and English version prEN 14063-1:2016 |
DIN EN 13403:2003-08 | VENTILATION FOR BUILDINGS - NON-METALLIC DUCTS - DUCTWORK MADE FROM INSULATION DUCTBOARDS |
BS EN 15026:2007 | Hygrothermal performance of building components and building elements. Assessment of moisture transfer by numerical simulation |
BS EN 13950:2014 | Gypsum board thermal/acoustic insulation composite panels. Definitions, requirements and test methods |
BS EN 13167 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
BS EN 13171 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE WOOD FIBRE (WF) PRODUCTS - SPECIFICATION |
BS EN 13165 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
UNE-EN 13166:2013 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
UNE-EN 13167:2013 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
UNE-EN 13164:2013 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
BS EN 13166 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
BS EN 15102 : 2007 | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
UNE-EN 13169:2013 | Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
ISO 13787:2003 | Thermal insulation products for building equipment and industrial installations Determination of declared thermal conductivity |
BS EN 12781:2001 | Wallcoverings. Specification for cork panels |
BS EN 13162 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
UNE-EN 13162:2013 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
UNE-EN 13165:2013 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
UNE-EN 13171:2013 | Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification |
UNE-EN 13163:2013 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
BS EN ISO 10456:2007 | Building materials and products. Hygrothermal properties. Tabulated design values and procedures for determining declared and design thermal values |
UNE-EN 16069:2013 | Thermal insulation products for buildings - Factory made products of polyethylene foam (PEF) - Specification |
UNE-EN 13170:2013 | Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
BS EN 12664:2001 | Thermal performance of building materials and products. Determination of thermal resistance by means of guarded hot plate and heat flow meter methods. Dry and moist products of medium and low thermal resistance |
UNE-EN 13168:2013 | Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
EN 14308:2015 | Thermal insulation products for building equipment and industrial installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products - Specification |
EN 14306:2015 | Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products - Specification |
EN 13950:2014 | Gypsum board thermal/acoustic insulation composite panels - Definitions, requirements and test methods |
EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam dispensed system before installation |
EN ISO 10077-1:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02) |
EN 14305:2015 | Thermal insulation products for building equipment and industrial installations - Factory made cellular glass (CG) products - Specification |
EN 15026:2007 | Hygrothermal performance of building components and building elements - Assessment of moisture transfer by numerical simulation |
EN 14317-1:2004 | Thermal insulation products for buildings - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 1: Specification for bonded and loose-fill products before installation |
EN 13168:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
EN 14316-1:2004 | Thermal insulation products for buildings - In-situ thermal insulation formed from expanded perlite (EP) products - Part 1: Specification for bonded and loose-fill products before installation |
EN 14307:2015 | Thermal insulation products for building equipment and industrial installations - Factory made extruded polystyrene foam (XPS) products - Specification |
EN 13164:2012+A1:2015 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
EN 16069:2012+A1:2015 | Thermal insulation products for buildings - Factory made products of polyethylene foam (PEF) - Specification |
EN 14309:2015 | Thermal insulation products for building equipment and industrial installations - Factory made products of expanded polystyrene (EPS) - Specification |
EN 13171:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification |
EN 16855-1:2017 | Walk-in cold rooms - Definition, thermal insulation performance and test methods - Part 1: Prefabricated cold room kits |
EN 15037-4:2010+A1:2013 | Precast concrete products - Beam-and-block floor systems - Part 4: Expanded polystyrene blocks |
EN 1520:2011 | Prefabricated reinforced components of lightweight aggregate concrete with open structure with structural or non-structural reinforcement |
EN 14320-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam spray system before installation |
EN 14304:2015 | Thermal insulation products for building equipment and industrial installations - Factory made flexible elastomeric foam (FEF) products - Specification |
EN 15037-5:2013 | Precast concrete products - Beam-and-block floor systems - Part 5: Lightweight blocks for simple formwork |
EN 15600-1:2010 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 1: Specification for bonded and loose-fill products before installation |
EN 14934:2007 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of extruded polystyrene foam (XPS) - Specification |
EN 15599-1:2010 | Thermal insulation products for building equipment and industrial installations - In-situ thermal insulation formed from expanded perlite (EP) products - Part 1: Specification for bonded and loose-fill products before installation |
EN 15632-1:2009+A1:2014 | District heating pipes - Pre-insulated flexible pipe systems - Part 1: Classification, general requirements and test methods |
EN 16012:2012+A1:2015 | Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance |
EN 14315-1:2013 | Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam spray system before installation |
EN 14314:2015 | Thermal insulation products for building equipment and industrial installations - Factory made phenolic foam (PF) products - Specification |
EN 14933:2007 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of expanded polystyrene (EPS) - Specification |
EN 15501:2015 | Thermal insulation products for building equipment and industrial installations - Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products - Specification |
EN ISO 13787:2003 | Thermal insulation products for building equipment and industrial installations - Determination of declared thermal conductivity (ISO 13787:2003) |
EN 14318-1:2013 | Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
EN 14313:2015 | Thermal insulation products for building equipment and industrial installations - Factory made polyethylene foam (PEF) products - Specification |
EN ISO 23993:2010 | Thermal insulation products for building equipment and industrial installations - Determination of design thermal conductivity (ISO 23993:2008, Corrected version 2009-10-01) |
EN 14620-4:2006 | Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 4: Insulation components |
EN 14303:2015 | Thermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products - Specification |
EN 16025-1:2013 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
06/30158376 DC : 0 | BS EN 15599-1 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
DIN EN 14318-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
17/30354084 DC : 0 | BS EN 16855-2 - WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 2: CUSTOMIZED COLD ROOMS |
BS EN 16012 : 2012 | THERMAL INSULATION FOR BUILDINGS - REFLECTIVE INSULATION PRODUCTS - DETERMINATION OF THE DECLARED THERMAL PERFORMANCE |
I.S. EN 15501:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXPANDED PERLITE (EP) AND EXFOLIATED VERMICULITE (EV) PRODUCTS - SPECIFICATION |
10/30213968 DC : 0 | BS EN 13165 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE RIGID POLYURETHANE FOAM (PU) PRODUCTS - SPECIFICATION |
BS EN 16855-1:2017 | Walk-in cold rooms. Definition, thermal insulation performance and test methods Prefabricated cold room kits |
DIN EN 14319-1:2013-04 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation |
05/30136538 DC : 0 | PREN 14307 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
03/310921 DC : 0 | EN 14732-1 - TIMBER STRUCTURES - PREFABRICATED WALL, FLOOR AND ROOF ELEMENTS - PART 1: PRODUCT REQUIREMENTS |
06/30158382 DC : 0 | BS EN 15600-1 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULATE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
08/30169556 DC : DRAFT APR 2008 | BS EN 13170 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
UNE-EN 16025-1:2016 | Thermal and/or sound insulating products in building construction - Bound EPS ballastings - Part 1: Requirements for factory premixed EPS dry plaster |
UNE-EN 14319-1:2013 | Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate foam (PIR) products - Part 1: Specification for the rigid foam dispensed system before installation |
15/30315093 DC : DRAFT MAY 2015 | BS EN 14303 - THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION |
PD CEN/TS 16354:2013 | Laminate floor coverings. Underlays. Specification, requirements and test methods |
DIN EN 14305:2016-03 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE CELLULAR GLASS (CG) PRODUCTS - SPECIFICATION |
10/30213989 DC : 0 | BS EN 16069 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF POLYETHYLENE FOAM (PEF) - SPECIFICATION |
BS EN 15600-1:2010 | Thermal insulation products for building equipment and industrial installations. In-situ thermal insulation formed from exfoliated vermiculite (EV) products Specification for bonded and loose-fill products before installation |
UNE-EN 15037-5:2013 | Precast concrete products - Beam-and-block floor systems - Part 5: Lightweight blocks for simple formwork |
04/30113504 DC : DRAFT MAY 2004 | BS EN 14933 - LIGHT WEIGHT FILL AND INSULATION PRODUCTS FOR CIVIL ENGINEERING APPLICATIONS - FACTORY MADE PRODUCTS OF EXPANDED POLYSTYRENE (EPS) - SPECIFICATION |
04/30126127 DC : 0 | EN 15102 - DECORATIVE WALLCOVERINGS - ROLL AND PANEL FORM |
I.S. EN 14315-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
UNE-EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane foam (PUR) products. Part 1: Specification for the rigid foam spray system before installation |
UNE-EN 15102:2008 | Decorative wallcoverings - Roll and panel form products |
UNE-EN 15501:2017 | Thermal insulation products for building equipment and industrial installations - Factory made expanded perlite (EP) and exfoliated vermiculite (EV) products - Specification |
PREN 13166 : DRAFT 2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION |
UNE-EN 15101-1:2015 | Thermal insulation products for buildings - In-situ formed loose fill cellulose (LFCI) products - Part 1: Specification for the products before installation |
PREN 13964 : DRAFT 2013 | SUSPENDED CEILINGS - REQUIREMENTS AND TEST METHODS |
I.S. EN 14064-1:2010 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSEFILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
BS EN 15101-1:2013 | Thermal insulation products for buildings. In-situ formed loose fill cellulose (LFCI) products Specification for the products before installation |
UNE-EN 15037-4:2010 | Precast concrete products - Beam-and-block floor systems - Part 4: Expanded polystyrene blocks |
I.S. EN 14318-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION |
S.R. CEN/TS 16354:2013 | LAMINATE FLOOR COVERINGS - UNDERLAYS - SPECIFICATION, REQUIREMENTS AND TEST METHODS |
BS EN 15037-4 : 2010 | PRECAST CONCRETE PRODUCTS - BEAM-AND-BLOCK FLOOR SYSTEMS - PART 4: EXPANDED POLYSTYRENE BLOCKS |
I.S. EN 15599-1:2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXPANDED PERLITE (EP) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
BS EN 14313 : 2009 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE POLYETHYLENE FOAM (PEF) PRODUCTS - SPECIFICATION |
UNI EN 15600-1 : 2010 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - IN-SITU THERMAL INSULATION FORMED FROM EXFOLIATED VERMICULITE (EV) PRODUCTS - PART 1: SPECIFICATION FOR BONDED AND LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
16/30313668 DC : 0 | BS EN 14064-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
DIN EN 14064-1:2010-06 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION |
DIN EN 15102:2016-02 (Draft) | DECORATIVE WALL COVERINGS - ROLL AND PANEL FORM |
17/30353879 DC : 0 | BS EN 17104 - THERMOPLASTICS RIGID PROTECTIVE WALLCOVERING PANELS FOR INTERNAL USE IN BUILDINGS - PERFORMANCE CHARACTERISTICS |
17/30360238 DC : 0 | BS EN 17140 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE VACUUM INSULATION PANELS (VIP) - SPECIFICATION |
ISO 8724:2009 | Cork decorative panels Specification |
I.S. EN 14307:2015 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE EXTRUDED POLYSTYRENE FOAM (XPS) PRODUCTS - SPECIFICATION |
I.S. EN 15632-1:2009 | DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS |
UNE-EN 13964:2016 | Suspended ceilings - Requirements and test methods |
BS EN 13163 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE EXPANDED POLYSTYRENE (EPS) PRODUCTS - SPECIFICATION |
BS EN 14063-1:2004 | Thermal insulation products for buildings. In-situ formed expanded clay lightweight aggregate products Specification for the loose-fill products before installation |
BS EN 13170 : 2012 | THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE PRODUCTS OF EXPANDED CORK (ICB) - SPECIFICATION |
BS EN 12825:2001 | Raised access floors |
BS EN 13085:2001 | Wallcoverings. Specification for cork rolls |
BS EN 14934:2007 | Thermal insulation and light weight fill products for civil engineering applications. Factory made products of extruded polystyrene foam (XPS). Specification |
BS EN 13964:2014 | Suspended ceilings. Requirements and test methods |
CEN/TS 15548-1:2014 | Thermal insulation products for building equipment and industrial installations - Determination of thermal resistance by means of the guarded hot plate method - Part 1: Measurements at elevated temperatures from 100 °C to 850 °C |
EN 13403:2003 | Ventilation for buildings - Non-metallic ducts - Ductwork made from insulation ductboards |
EN 13170:2012+A1:2015 | Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
EN 13055:2016 | Lightweight aggregates |
EN 13169:2012+A1:2015 | Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
EN 13167:2012+A1:2015 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
DIN EN ISO 13787:2003-07 | THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - DETERMINATION OF DECLARED THERMAL CONDUCTIVITY |
DIN EN 14934:2007-12 | Thermal insulation and light weight fill products for civil engineering applications - Factory made products of extruded polystyrene foam (XPS) - Specification |
DIN EN 13055-2:2004-09 | LIGHTWEIGHT AGGREGATES - PART 2: LIGHTWEIGHT AGGREGATES FOR BITUMINOUS MIXTURES AND SURFACE TREATMENTS AND FOR UNBOUND AND BOUND APPLICATIONS |
EN 12825:2001 | Raised access floors |
DIN EN 15026:2007-07 | Hygrothermal performance of building components and building elements - Assessment of moisture transfer by numerical simulation |
DIN EN 14063-1:2004-11 | Thermal insulation materials and products - In-situ formed expanded clay lightweight aggregate products (LWA) - Part 1: Specification for the loose-fill products before installation; German version EN 14063-1:2004 |
EN 13165:2012+A2:2016 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
UNE-EN 13162:2013+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
EN 1946-3:1999 | Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 3: Measurements by heat flow meter method |
EN 12939:2000 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Thick products of high and medium thermal resistance |
EN 1946-2:1999 | Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 2: Measurements by guarded hot plate method |
ISO 8302:1991 | Thermal insulation — Determination of steady-state thermal resistance and related properties — Guarded hot plate apparatus |
ISO 8301:1991 | Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter apparatus |
EN 12664:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |