Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 12341:2014

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter

Withdrawn date

30-11-2014

Published date

21-05-2014

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and
  abbreviations
4 Principle
5 Equipment and facilities
6 Filter conditioning, sampling and
  weighing procedures
7 Ongoing quality control
8 Expression of results
9 Performance characteristics of the
  method
Annex A (normative) - Design drawing of standard
        inlet for the sampling of PM[10] and PM[2,5]
Annex B (normative) - Other samplers
Annex C (informative) - Scheme of PM standard
        sampler
Annex D (informative) - Suitability tests for filters
Annex E (normative) - Initial suitability testing
        of weighing facilities
Annex F (informative) - Results of experimental
        work
Annex G (informative) - Impactor efficiency
Bibliography

This European Standard describes a standard method for determining the PM10 or PM2,5 mass concentrations of suspended particulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance.Measurements are performed with samplers with inlet designs as specified in Annex A, operating at a nominal flow rate of 2,3 m3/h, over a nominal sampling period of 24 h. Measurement results are expressed in µg/m3, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling.The range of application of this European Standard is from approximately 1 µg/m3 (i.e. the limit of detection of the standard measurement method expressed as its uncertainty) up to 150 µg/m3 for PM10 and 120 µg/m3 for PM2,5.NOTE 1Although the European Standard is not validated for higher concentrations, its range of application could well be extended to ambient air concentrations up to circa 200 µg/m3 when using suitable filter materials (see 5.1.4).This European Standard describes procedures and gives requirements for the use of so-called sequential samplers, equipped with a filter changer, suitable for extended stand-alone operation. Sequential samplers are commonly used throughout the European Union for the measurement of concentrations in ambient air of PM10 or PM2,5. However, this European Standard does not exclude the use of single-filter samplers.This European Standard does not give procedures for the demonstration of equivalence of other sampler types, e.g. equipped with a different aerosol classifier and/or operating at different flow rates. Such procedures and requirements are given in detail in the Guide to the Demonstration of Equivalence of Ambient Air Monitoring Methods [11] and for automated continuous PM monitors (see CEN/TS 16450:2013).The present European Standard represents an evolution of earlier European Standards (EN 12341:1998 and EN 14907:2005) through the development of the 2,3 m3/h sampler to include constraints on the filter temperature during and after sampling and the ability to monitor temperatures at critical points in the sampling system. It is recommended that when equipment is procured it complies fully with the present European Standard. However, older versions of these 2,3 m3/h samplers that do not employ sheath air cooling, the ability to cool filters after sampling, or the ability to monitor temperatures at critical points in the sampling system have a special status in terms of their use as reference samplers. Historical results obtained using these samplers will remain valid. These samplers can still be used for monitoring purposes and for equivalence trials, provided that a well justified additional allowance is made to their uncertainties (see Annex B).In addition, three specific sampling systems - the -long nozzle - 2,3 m3/h sampler and the 68 m3/h sampler for PM10 in EN 12341:1998, and the 30 m3/h PM2,5 inlet in EN 14907:2005 - also have a special status in terms of their use as reference samplers. Historical results obtained using these samplers will remain valid. These samplers can still be used for monitoring purposes and for equivalence trials, provided that a well-justified additional allowance is made to their uncertainties (see Annex B).Other sampling systems, as described in Annex B of this European Standard, can be used provided that a well justified additional allowance is made to their uncertainties as derived from equivalence tests.NOTE 2By evaluating existing data it has been shown that these samplers give results for PM10 and PM2,5 that are equivalent to those obtained by application of this European Standard. Results are shown in Annex B.This European Standard also provides guidance for the selection and testing of filters with the aim of reducing the measurement uncertainty of the results obtained when applying this European Standard.

Committee
CEN/TC 264
DevelopmentNote
Supersedes PREN 12341 & EN 14907. (06/2014)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
NEN EN 12341 : 2014 Identical
NF EN 12341 : 2014 Identical
BS EN 12341:2014 Identical
NS EN 12341 : 2014 Identical
NBN EN 12341 : 2014 Identical
UNI EN 12341 : 2014 Identical
PN EN 12341 : 2014 Identical
SN EN 12341:2014 Identical
I.S. EN 12341:2014 Identical
DS EN 12341 : 2014 Identical
ONORM EN 12341 : 2014 Identical
DIN EN 12341:2014-08 Identical
UNE-EN 12341:2015 Identical
DIN EN 12341:1999-03 Identical

I.S. EN ISO 16890-1:2016 AIR FILTERS FOR GENERAL VENTILATION - PART 1: TECHNICAL SPECIFICATIONS, REQUIREMENTS AND CLASSIFICATION SYSTEM BASED UPON PARTICULATE MATTER EFFICIENCY (EPM) (ISO 16890-1:2016)
DIN EN 15429-3:2015-05 SWEEPERS - PART 3: EFFICIENCY OF PARTICULATE MATTER COLLECTION - TESTING AND EVALUATION
PD ISO/TS 20593:2017 Ambient air. Determination of the mass concentration of tire and road wear particles (TRWP). Pyrolysis-GC-MS method
15/30314070 DC : 0 BS EN 16450 - AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
12/30268424 DC : 0 BS EN 12341 - AMBIENT AIR - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM10 OR PM2,5 MASS CONCENTRATION OF SUSPENDED PARTICULATE MATTER
BS ISO 11844-3 : 2006 CORROSION OF METALS AND ALLOYS - CLASSIFICATION OF LOW CORROSIVITY OF INDOOR ATMOSPHERES - PART 3: MEASUREMENT OF ENVIRONMENTAL PARAMETERS AFFECTING INDOOR CORROSIVITY
UNI EN 15445 : 2008 FUGITIVE AND DIFFUSE EMISSIONS OF COMMON CONCERN TO INDUSTRY SECTORS - QUALIFICATION OF FUGITIVE DUST SOURCES BY REVERSE DISPERSION MODELLING
15/30314073 DC : 0 BS 16913 - AMBIENT AIR - STANDARD METHOD FOR MEASUREMENT OF NO[3][-], SO[4][2-], CL[-], NH[4][+], NA[+], K[+], MG[2+], CA[2+] IN PM2,5
PD CEN/TR 16269:2011 Ambient air. Guide for the measurement of anions and cations in PM2,5
04/19981537 DC : DRAFT MARCH 2004 EN 14902 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB/CD/AS/NI IN AMBIENT AIR
01/715983 DC : DRAFT NOV 2001 ISO/CD 11844-3 - CORROSION OF METALS AND ALLOYS - CLASSIFICATION OF LOW CORROSIVITY OF INDOOR ATMOSPHERES - PART 3: MEASUREMENT OF ENVIRONMENTAL PARAMETERS AFFECTING INDOOR CORROSIVITY
I.S. EN 16909:2017 AMBIENT AIR - MEASUREMENT OF ELEMENTAL CARBON (EC) AND ORGANIC CARBON (OC) COLLECTED ON FILTERS
I.S. EN 16450:2017 AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
EN ISO 11844-3:2008 Corrosion of metals and alloys - Classification of low corrosivity of indoor atmospheres - Part 3: Measurement of environmental parameters affecting indoor corrosivity (ISO 11844-3:2006)
CEN/TS 16115-1:2011 Ambient air quality - Measurement of bioaerosols - Part 1: Determination of moulds using filter sampling systems and culture-based analyses
DIN EN 15549:2008-06 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
CEN/TR 16998:2016 Ambient air - Report on nitro- and oxy-PAHs - Origin, toxicity, concentrations and measurement methods
DIN EN 14907:2005-11 AMBIENT AIR QUALITY - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM[2,5] MASS FRACTION OF SUSPENDED PARTICULATE MATTER
PD CEN/TS 16450:2013 Ambient air. Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
UNI CEN/TS 16115-1 : 2011 AMBIENT AIR QUALITY - MEASUREMENT OF BIOAEROSOLS - PART 1: DETERMINATION OF MOULDS USING FILTER SAMPLING SYSTEMS AND CULTURE-BASED ANALYSES
I.S. EN 14907:2005 AMBIENT AIR QUALITY - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM[2,5] MASS FRACTION OF SUSPENDED PARTICULATE MATTER
BS EN 15549:2008 Air quality. Standard method for the measurement of the concentration of benzo(a)pyrene in ambient air
DD CEN/TS 16115-1:2011 Ambient air quality. Measurement of bioaerosols Determination of moulds using filter sampling systems and culture-based analyses
12/30260963 DC : 0 BS EN 12341 - AMBIENT AIR - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM 10 OR PM 2,5 MASS CONCENTRATION OF SUSPENDED PARTICULATE MATTER
DIN EN 15445:2008-04 FUGITIVE AND DIFFUSE EMISSIONS OF COMMON CONCERN TO INDUSTRY SECTORS - QUALIFICATION OF FUGITIVE DUST SOURCES BY REVERSE DISPERSION MODELLING
UNI CEN/TS 16450 : 2013 AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
BS EN 15429-3:2015 Sweepers Efficiency of particulate matter collection. Testing and Evaluation
DIN EN ISO 11844-3:2008-08 CORROSION OF METALS AND ALLOYS - CLASSIFICATION OF LOW CORROSIVITY OF INDOOR ATMOSPHERES - PART 3: MEASUREMENT OF ENVIRONMENTAL PARAMETERS AFFECTING INDOOR CORROSIVITY
BS EN 16450:2017 Ambient air. Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
S.R. CEN/TS 16645:2014 AMBIENT AIR - METHOD FOR THE MEASUREMENT OF BENZ[A]ANTHRACENE, BENZO[B]FLUORANTHENE, BENZO[J]FLUORANTHENE, BENZO[K]FLUORANTHENE, DIBENZ[A,H]ANTHRACENE, INDENO[1,2,3-CD]PYRENE AND BENZO[GHI]PERYLENE
BS EN 16909:2017 Ambient air. Measurement of elemental carbon (EC) and organic carbon (OC) collected on filters
I.S. EN ISO 11844-3:2008 CORROSION OF METALS AND ALLOYS - CLASSIFICATION OF LOW CORROSIVITY OF INDOOR ATMOSPHERES - PART 3: MEASUREMENT OF ENVIRONMENTAL PARAMETERS AFFECTING INDOOR CORROSIVITY
I.S. CEN/TR 15230:2005 WORKPLACE ATMOSPHERES - GUIDANCE FOR SAMPLING OF INHALABLE, THORACIC AND RESPIRABLE AEROSOL FRACTIONS
ISO/TS 20593:2017 Ambient air — Determination of the mass concentration of tire and road wear particles (TRWP) — Pyrolysis-GC-MS method
ISO 11844-3:2006 Corrosion of metals and alloys Classification of low corrosivity of indoor atmospheres Part 3: Measurement of environmental parameters affecting indoor corrosivity
UNE-EN 12341:2015 Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter
DIN EN ISO 16890-1:2017-08 AIR FILTERS FOR GENERAL VENTILATION - PART 1: TECHNICAL SPECIFICATIONS, REQUIREMENTS AND CLASSIFICATION SYSTEM BASED UPON PARTICULATE MATTER EFFICIENCY (EPM) (ISO 16890-1:2016)
DIN EN 12341:1999-03 AMBIENT AIR - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM[10] OR PM[2],[5] MASS CONCENTRATION OF SUSPENDED PARTICULATE MATTER
DIN EN 16909:2017-06 AMBIENT AIR - MEASUREMENT OF ELEMENTAL CARBON (EC) AND ORGANIC CARBON (OC) COLLECTED ON FILTERS
VDI 3803 Blatt 4:2012-09 Air-conditioning, system requirements - Air filter systems (VDI Ventilation Code of Practice)
VDI 3787 Blatt 1:2015-09 Environmental meteorology - Climate and air pollution maps for cities and regions
VDI 2267 Blatt 12:2008-10 Determination of suspended matter in ambient air - Measurement of As, Ca, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb and Zn by energy dispersive X-ray fluorescense (ED XRF)
VDI 2463 Blatt 7:2014-05 Particulate matter measurement - Determination of suspended particulate matter and gaseous chemical compounds in ambient air and indoor air - Active sampling via low-volume sampler (LVS)
VDI 3871:2016-12 (Draft) Measurement of particles in ambient air - Electrical aerosol monitors based on diffusion charging
VDI 3787 Blatt 9:2004-12 Environmental meteorology - Provision for climate and air quality in regional planning
VDI 2095 Blatt 1:2011-03 Emission control - Treatment of mineral construction-site and demolition waste - Stationary and mobile demolition waste recycling facilities
VDI 3790 Blatt 3:2010-01 Environmental meteorology - Emission of gases, odours and dusts from diffuse sources - Storage, transhipment and transportation of bulk materials
VDI 2465 Blatt 2:2016-11 Measurement of soot (ambient air) - Thermographic determination of elemental carbon after thermal desorption of organic carbon
VDI 2267 Blatt 3:2015-03 Determination of suspended matter in ambient air - Digestion variants for dust samples for the subsequent determination of the mass concentration of Al, Sb, As, Pb, Cd, Ca, Cr, Co, Fe, K, Cu, Mg, Mn, Na, Ni, Se, V and Zn
VDI 2119:2013-06 Ambient air measurements - Sampling of atmospheric particles > 2,5 ?m on an acceptor surface using the Sigma-2 passive sampler - Characterisation by optical microscopy and calculation of number settling rate and mass concentration
UNE-EN 16450:2017 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
DIN EN 16909 E : 2017 AMBIENT AIR - MEASUREMENT OF ELEMENTAL CARBON (EC) AND ORGANIC CARBON (OC) COLLECTED ON FILTERS
04/30123368 DC : DRAFT OCT 2004 EN 15051 - WORKPLACE ATMOSPHERES - MEASUREMENT OF THE DUSTINESS OF BULK MATERIALS - REQUIREMENTS AND REFERENCE TEST METHODS
BS EN 16913:2017 Ambient air. Standard method for measurement of NO<sub>3</sub><sup>-</sup>, SO<sub>4</sub><sup>2-</sup>, Cl<sup>-</sup>, NH<sub>4</sub><sup>+</sup>, Na<sup>+</sup>, K<sup>+</sup>, Mg<sup>2+</sup>, Ca<sup>2+</sup> in PM2,5 as deposited on filters
PREN 12341 : DRAFT 2012 AMBIENT AIR - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM 10 OR PM 2,5 MASS CONCENTRATION OF SUSPENDED PARTICULATE MATTER
S.R. CEN/TR 16269:2011 AMBIENT AIR - GUIDE FOR THE MEASUREMENT OF ANIONS AND CATIONS IN PM2,5
S.R. CEN/TR 16998:2016 AMBIENT AIR - REPORT ON NITRO- AND OXY-PAHS - ORIGIN, TOXICITY, CONCENTRATIONS AND MEASUREMENT METHODS
UNI EN ISO 11844-3 : 2008 CORROSION OF METALS AND ALLOYS - CLASSIFICATION OF LOW CORROSIVITY OF INDOOR ATMOSPHERES - PART 3: MEASUREMENT OF ENVIRONMENTAL PARAMETERS AFFECTING INDOOR CORROSIVITY
UNE-CEN/TS 16115-1:2013 Ambient air quality - Measurement of bioaerosols - Part 1: Determination of moulds using filter sampling systems and culture-based analyses
CEN/TR 15230:2005 Workplace atmospheres - Guidance for sampling of inhalable, thoracic and respirable aerosol fractions
I.S. EN 15549:2008 AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF BENZO[A]PYRENE IN AMBIENT AIR
DIN EN 12341:2014-08 Ambient air - Standard gravimetric measurement method for the determination of the PM or PM mass concentration of suspended particulate matter
BS EN 14907:2005 Ambient air quality. Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter
UNE-EN ISO 16890-1:2017 Air filters for general ventilation - Part 1: Technical specifications, requirements and classification system based upon particulate matter efficiency (ePM) (ISO 16890-1:2016)
BS EN 14902:2005 Ambient air quality. Standard method for the measurement of Pb, Cd, AS, and Ni in the PM 10 fraction of suspended particulate matter
UNI EN 14902 : 2005 AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB, CD, AS AND NI IN THE PM10 FRACTION OF SUSPENDED PARTICULATE MATTER
13/30284868 DC : 0 BS EN 15429-3 - SWEEPERS - PART 3: EFFICIENCY OF PARTICULATE MATTER COLLECTION - TESTING AND EVALUATION
PD CEN/TR 15230:2005 Workplace atmospheres. Guidance for sampling of inhalable, thoracic and respirable aerosol fractions
04/30111960 DC : DRAFT APR 2004 EN 14907 - AMBIENT AIR QUALITY - REFERENCE GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM2,5 MASS FRACTION OF SUSPENDED PARTICULATE MATTER
I.S. EN 16913:2017 AMBIENT AIR - STANDARD METHOD FOR MEASUREMENT OF NO[3][-], SO[4][2-], CL[-], NH[4][+], NA[+], K[+], MG[2+], CA[2+] IN PM2,5 AS DEPOSITED ON FILTERS
15/30314076 DC : 0 BS EN 16909 - AMBIENT AIR - MEASUREMENT OF ELEMENTAL CARBON (EC) AND ORGANIC CARBON (OC) DEPOSITED ON FILTERS
UNI EN 15549 : 2008 AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF BENZO[A]PYRENE IN AMBIENT AIR
PD CEN/TR 16998:2016 Ambient air. Report on nitro- and oxy-PAHs. Origin, toxicity, concentrations and measurement methods
ISO 16890-1:2016 Air filters for general ventilation — Part 1: Technical specifications, requirements and classification system based upon particulate matter efficiency (ePM)
BS EN ISO 16890-1:2016 Air filters for general ventilation Technical specifications, requirements and classification system based upon particulate matter efficiency (ePM)
14/30266374 DC : 0 BS EN ISO 16890-1 - AIR FILTERS FOR GENERAL VENTILATION - PART 1: TECHNICAL SPECIFICATIONS, REQUIREMENTS AND EFFICIENCY CLASSIFICATION SYSTEM BASED UPON PARTICULATE MATTER (PM)
DIN EN 14902:2005-10 AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB, CD, AS AND NI IN THE PM10 FRACTION OF SUSPENDED PARTICULATE MATTER
EN 15445:2008 Fugitive and diffuse emissions of common concern to industry sectors - Qualification of fugitive dust sources by Reverse Dispersion Modelling
EN ISO 16890-1:2016 Air filters for general ventilation - Part 1: Technical specifications, requirements and classification system based upon particulate matter efficiency (ePM) (ISO 16890-1:2016)
EN 15549:2008 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
EN 16909:2017 Ambient air - Measurement of elemental carbon (EC) and organic carbon (OC) collected on filters
EN 15429-3:2015 Sweepers - Part 3: Efficiency of particulate matter collection - Testing and Evaluation
06/30142044 DC : 0 EN 15549 - AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF BENZO(A)PYRENE IN AMBIENT AIR
BS EN ISO 11844-3:2008 Corrosion of metals and alloys. Classification of low corrosivity of indoor atmospheres Measurement of environmental parameters affecting indoor corrosivity
BS EN 15445:2008 Fugitive and diffuse emissions of common concern to industry sectors. Qualification of fugitive dust sources by reverse dispersion modelling
PD CEN/TS 16645:2014 Ambient air. Method for the measurement of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, dibenz[a,h]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene
UNI CEN/TS 16645 : 2014 AMBIENT AIR - METHOD FOR THE MEASUREMENT OF BENZ[A]ANTHRACENE, BENZO[B]FLUORANTHENE, BENZO[J]FLUORANTHENE, BENZO[K]FLUORANTHENE, DIBENZ[A,H]ANTHRACENE, INDENO[1,2,3-CD]PYRENE AND BENZO[GHI]PERYLENE
S.R. CEN TS 16115-1:2011 AMBIENT AIR QUALITY - MEASUREMENT OF BIOAEROSOLS - PART 1: DETERMINATION OF MOULDS USING FILTER SAMPLING SYSTEMS AND CULTURE-BASED ANALYSES
S.R. CEN/TS 16450:2013 AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
EN 16913:2017 Ambient air - Standard method for measurement of NO3¯, SO4²¯, Cl¯, NH4+, Na+, K+, Mg²+, Ca²+ in PM2,5 as deposited on filters
DIN EN 16450:2015-10 (Draft) AMBIENT AIR - AUTOMATED MEASURING SYSTEMS FOR THE MEASUREMENT OF THE CONCENTRATION OF PARTICULATE MATTER (PM10; PM2,5)
DIN EN 16909:2015-10 (Draft) AMBIENT AIR - MEASUREMENT OF ELEMENTAL CARBON (EC) AND ORGANIC CARBON (OC) COLLECTED ON FILTERS
UNE-EN 15429-3:2015 Sweepers - Part 3: Efficiency of particulate matter collection - Testing and Evaluation
I.S. EN 15445:2008 FUGITIVE AND DIFFUSE EMISSIONS OF COMMON CONCERN TO INDUSTRY SECTORS - QUALIFICATION OF FUGITIVE DUST SOURCES BY REVERSE DISPERSION MODELLING
DIN EN 16913:2015-10 (Draft) AMBIENT AIR - STANDARD METHOD FOR MEASUREMENT OF NO[3][-], SO[4][2-], CL[-], NH[4][+], NA[+], K[+], MG[2+], CA[2+] IN PM2,5 AS DEPOSITED ON FILTERS
I.S. EN 15429-3:2015 SWEEPERS - PART 3: EFFICIENCY OF PARTICULATE MATTER COLLECTION - TESTING AND EVALUATION
CEN/TR 16269:2011 Ambient air - Guide for the measurement of anions and cations in PM2,5
EN 16450:2017 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
CEN/TS 16450:2013 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
CEN/TS 16645:2014 Ambient air - Method for the measurement of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, dibenz[a,h]anthracene, indeno[1,2,3-cd]pyrene and benzo[ghi]perylene

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN 13274-7:2008 Respiratory protective devices - Methods of test - Part 7: Determination of particle filter penetration
CEN/TR 16269:2011 Ambient air - Guide for the measurement of anions and cations in PM2,5
EN 14907:2005 Ambient air quality - Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter
CEN/TR 16243:2011 Ambient air quality - Guide for the measurement of elemental carbon (EC) and organic carbon (OC) deposited on filters
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
CEN/TS 16450:2013 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
EN 15549:2008 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more