Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DIN EN 61642 : 1998

Current

Current

The latest, up-to-date edition.

INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS

Available format(s)

Hardcopy

Language(s)

German

Published date

01-11-1998

$180.95
Including GST where applicable

1 Allgemeines
  1.1 Anwendungsbereich und Zweck
  1.2 Normative Verweisungen
  1.3 Begriffe
  1.4 Allgemeine Betrachtungen
      1.4.1 Wechselstromoberschwingungen
      1.4.2 Blindleistung
2 Resonanzprobleme und Lösungen
  2.1 Einführung
  2.2 'Blick' auf die Netzimpedanz, 'Blick' auf die
      Lastsammelschienenimpedanz
  2.3 Beispiel für eine Serienresonanz
  2.4 Beispiel für eine Parallelresonanz
  2.5 Lösungswege zur Vermeidung von Resonanzen
      2.5.1 Kondensator-Drosselspulen-Schaltung:
            Serienresonanz
      2.5.2 Kondensator-Drosselspulen-Schaltung:
            Parallelresonanz
3 Parallelkondensatoren und Filter in Netzen mit
  Spannungen bis 1000 V
  3.1 Einführung
  3.2 Parallelkondensatoren
  3.3 Verstimmtes Filter
  3.4 Abgestimmtes Filter
  3.5 Auswahl der Bauteile
      3.5.1 Kondensatoren
      3.5.2 Drosselspulen
      3.5.3 Schaltschütze und/oder Leistungsschalter
      3.5.4 Kurzschlussschutz (Sicherungen)
  3.6 Störung von Rundsteueranlagen durch
      Parallelkondensatoren und Filter
      3.6.1 Parallelkondensatoren
      3.6.2 Verstimmtes Filter
      3.6.3 Abgestimmtes Filter
4 Parallelkondensatoren und Filter in Netzen über 1000 V
  4.1 Einführung
  4.2 Besondere Anforderungen
  4.3 Wahl der Anlage zur Leistungsfaktorkorrektur
  4.4 Filterarten
  4.5 Auswahl der Filterbauelemente
      4.5.1 Leistungsschalter
      4.5.2 Kondensatoren
      4.5.3 Drosselspulen
      4.5.4 Widerstände
      4.5.5 Relaisschutz
  4.6 Störung von Rundsteueranlagen durch
Anhang A (informativ) Literaturhinweise
Anhang ZA (normativ) Normative Verweisungen auf
       internationale Publikationen mit ihren entsprechenden
       europäischen Publikationen

Provides guidelines for use of passive a.c. harmonic filters and shunt capacitors for limiting harmonics and power factor correction intended for use in industrial applications, at low and high voltages. Applies to harmonic orders higher than 1 and not exceeding 25.

DocumentType
Standard
Pages
0
PublisherName
Verband Deutscher Elektrotechniker
Status
Current

Standards Relationship
BS EN 61642:1998 Identical
NF EN 61642 : 1998 Identical
EN 61642:1997 Identical
NBN EN 61642 : 1998 Identical
IEC 61642:1997 Identical
VDE 0560-430 : 1998 Identical
I.S. EN 61642:1999 Identical
SN EN 61642 : 1997 Identical

IEC 60252:1993 A.C. motor capacitors
DIN V ENV 61000-2-2 : 1994 ELECTROMAGNETIC COMPATIBILITY (EMC) ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
IEC 60050-131:2002 International Electrotechnical Vocabulary (IEV) - Part 131: Circuit theory
VDE 0636-10 : 2005
DIN EN 61048 : 2016 AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006 + A1:2015)
VDE 0560-8:2014-07 AC MOTOR CAPACITORS - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDANCE FOR INSTALLATION AND OPERATION (IEC 60252-1:2010 + A1:2013)
DIN IEC 60871-2 : 1993 CAPACITORS - SHUNT CAPACITORS FOR A. C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 660 V - PART 2: ENDURANCE TESTING
VDE 0560-61 : 2016 AUXILIARIES FOR LAMPS - CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - GENERAL AND SAFETY REQUIREMENTS (IEC 61048:2006 + A1:2015)
IEC 61048:2006+AMD1:2015 CSV Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements
VDE 0670-104 : 1992 A.C. SWITCHGEAR AND CONTROLGEAR FOR VOLTAGES ABOVE 1 KV - HIGH-VOLTAGE A.C. CIRCUIT-BREAKERS - TYPE TESTS AND ROUTINE TESTS
IEC 60265-2:1988 High-voltage switches. Part 2: High-voltage switches for rated voltages of 52 kV and above
VDE 0670-302 : 98 AMD 2 99 HIGH-VOLTAGE SWITCHES - PART 2: HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 KV AND ABOVE
VDE 0532-20 : 1994 REACTORS
IEC 60056:1987 High-voltage alternating-current circuit-breakers
IEC 60549:2013 High-voltage fuses for the external protection of shunt capacitors
VDE 0560-48 : 2003 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation (IEC 60931-1:1996 + A1:2002);
VDE 0670-4 : 2015 HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES (IEC 60282-1:2009 + A1:2014)
DIN EN 60931-1 : 2003 Shunt power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV<br>Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation<br>(IEC 60931-1:1996 + A1:2002);
VDE 0560-46 : 2014-11 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION (IEC 60831-1:2014 + COR.:2014)
IEC 61049:1991 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements
IEC 60291:1969 Fuse definitions
IEC 60050-421:1990 International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors
IEC 60871-1:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 1: General
DIN EN 60289 : 2003 REACTORS
DIN EN 60252 : 1994 CAPACITORS - MOTOR CAPACITORS
DIN VDE 0636-10 : 1992 LOW-VOLTAGES FUSES; GENERAL REQUIREMENTS
IEC 60255-6:1988 Electrical relays - Part 6: Measuring relays and protection equipment
VDE 0839-2-2 : 2003 ELEKTROMAGNETISCHE VERTRAEGLICHKEIT (EMV) - UMGEBUNGSBEDINGUNGEN - VERTRAEGLICHKEITSPEGEL FUER NIEDERFREQUENTE LEITUNGSGEFUEHRTE STOERGROESSEN UND SIGNALUEBERTRAGUNG IN OEFFENTLICHEN NIEDERSPANNUNGSNETZEN
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 60831-1:2014 RLV Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 000 V - Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation
DIN EN 60282-1 : 2015 HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES (IEC 60282-1:2009 + A1:2014)
VDE 0560-120 : 2008 CAPACITORS FOR POWER ELECTRONICS
DIN IEC 60050-131:1983-01 INTERNATIONAL ELECTROTECHNICAL VOCABULARY - CHAPTER 131: ELECTRIC AND MAGNETIC CIRCUITS
DIN EN 61049 : 1994 CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - PERFORMANCE REQUIREMENTS
DIN EN 60071-1 : 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60050-436:1990 International Electrotechnical Vocabulary (IEV) - Part 436: Power capacitors
VDE 0435-301 : 1994 COR 1 2008 ELECTRICAL RELAYS - PART 6: MEASURING RELAYS AND PROTECTION EQUIPMENT
DIN EN 60255-6 : 1994 COR 1 2008 ELECTRICAL RELAYS - PART 6: MEASURING RELAYS AND PROTECTION EQUIPMENT
VDE 0560-62 : 1994 CAPACITORS FOR USE IN TUBULAR FLUORESCENT AND OTHER DISCHARGE LAMP CIRCUITS - PERFORMANCE REQUIREMENTS
VDE 0435-302 : 1988 ELECTRICAL RELAYS; ELECTROMECHANICAL MEASURING RELAYS
IEC 60110:1973 Recommendation for capacitors for inductive heat generating plants operating at frequencies between 40 and 24 000 Hz
IEC 60289:1988 Reactors
DIN VDE 0670-104 : 1992 A.C. SWITCHGEAR AND CONTROLGEAR FOR VOLTAGES ABOVE 1 KV - HIGH-VOLTAGE A.C. CIRCUIT-BREAKERS - TYPE TESTS AND ROUTINE TESTS
IEC TS 60871-2:2014 Shunt capacitors for a.c. power systems having a rated voltage above 1 000 V - Part 2: Endurance testing
DIN EN 60831-1 : 2014-11 SHUNT POWER CAPACITORS OF THE SELF-HEALING TYPE FOR A.C. SYSTEMS HAVING A RATED VOLTAGE UP TO AND INCLUDING 1000 V - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDE FOR INSTALLATION AND OPERATION (IEC 60831-1:2014 + COR.:2014)
IEC 60242:1967 Standard frequencies for centralized network control installations
VDE 0560-420 : 1993 CAPACITORS - SHUNT CAPACITORS FOR A. C. POWER SYSTEMS HAVING A RATED VOLTAGE ABOVE 660 V - PART 2: ENDURANCE TESTING

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.