DIN EN 60719 : 1994
Current
The latest, up-to-date edition.
CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
Hardcopy
German
01-02-1994
Vorwort
Anerkennungsnotiz
1 Allgemeines
2 Unterer Grenzwert des mittleren Aussendurchmessers
3 Oberer Grenzwert des mittleren Aussendurchmessers
4 Wanddicke der vorgeschriebenen Umhüllungen, ausser
der Isolierung und dem Mantel (den Mänteln)
Anhang ZA (normativ) Andere in dieser Norm zitierte
Internationale Normen mit den Verweisungen
der entsprechenden Europäischen Normen
Specifies a method for the calculation of the lower and upper limits for the average outer diameter of cables and the outer dimensions of flat cords with circular copper conductors and of rated voltages up to and including 450/750 V. Does not apply to mineral insulated cables. Coverage includes: upper limit for the average outer diameter; lower limit for the average outer diameter; thickness of the mandatory coverings other than the insulation and the sheaths.
DocumentType |
Standard
|
Pages |
0
|
PublisherName |
Verband Deutscher Elektrotechniker
|
Status |
Current
|
Standards | Relationship |
NF EN 60719 : 1994 | Identical |
IEC 60719:1992 | Identical |
NBN EN 60719 : 1994 | Identical |
I.S. EN 60719:1994 | Identical |
SN EN 60719 : 1993 | Identical |
VDE 0299-2 : 1994 | Identical |
UNE-EN 60719:1994 | Identical |
BS EN 60719:1993 | Identical |
EN 60719:1993 | Identical |
DIN VDE 0281-3 : 2001 AMD 2 2009 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING |
VDE 0281-9 : 2001 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES |
VDE 0281-12 : 2003 | CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES SOUPLES RESISTANT A LA CHALEUR |
VDE 0281-3 : 2001 AMD 2 2009 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING |
VDE 0281-7 : 2001 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREES C |
DIN VDE 0281-7 : 2001 | POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE |
IEC 60502:1994 | Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV |
DIN VDE 0299-1 : 1986 | CALCULATION METHOD ON THE BASIS OF FICTITIOUS DIAMETERS FOR DETERMINATION OF DIMENSIONS OF PROTECTIVE COVERINGS FOR CABLES AND FLEXIBLE CORDS FOR POWER INSTALLATIONS - PART 1: POWER CABLES |