INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
22-11-2022
01-10-2022
1 Scope
2 Normative references
3 Definitions
3.1 Insulation co-ordination
3.2 External insulation
3.3 Internal insulation
3.4 Self-restoring insulation
3.5 Non-self-restoring insulation
3.6 Insulation configuration terminal
3.7 Insulation configuration
3.8 Normal voltage of a system
3.9 Highest voltage of a system
3.10 Highest voltage for equipment (Um)
3.11 Isolated neutral system
3.12 Solidly earthed neutral system
3.13 Impedance earthed (neutral) system
3.14 Resonant earthed (neutral) system
3.15 Earth fault factor
3.16 Overvoltage
3.17 Classification of voltages and overvoltages
3.18 Standard voltage shapes
3.19 Representative overvoltages (Urp)
3.20 Overvoltage limiting device
3.21 Lightning (or switching) impulse protective level
3.22 Performance criterion
3.23 Withstand voltage
3.24 Co-ordination withstand voltage (Ucw)
3.25 Co-ordination factor (Kc)
3.26 Standard reference atmospheric conditions
3.27 Required withstand voltage (Urw)
3.28 Atmospheric correction factor (Ka)
3.29 Safety factor (Ks)
3.30 Standard withstand voltage (Uw)
3.31 Test conversion factor (Kt)
3.32 Rated insulation level
3.33 Standard insulation level
3.34 Standard withstand voltage tests
4 Procedure for insulation co-ordination
4.1 General outline of the procedure
4.2 Determination of the representative overvoltages (Urp)
4.3 Determination of the co-ordination withstand
voltages (Ucw)
4.4 Determination of the required withstand
voltages (Urw)
4.5 Selection of the rated insulation level
4.6 List of standard short-duration power frequency
withstand voltages
4.7 List of standard impulse withstand voltages
4.8 Ranges for highest voltage for equipment
4.9 Selection of the standard insulation levels
5 Requirements for standard withstand voltage tests
5.1 General requirements
5.2 Standard short-duration power-frequency
withstand voltage tests
5.3 Standard impulse withstand voltage tests
5.4 Alternative test situation
5.5 Phase-to-phase and longitudinal insulation
standard withstand voltage tests for
equipment in range I
5.6 Phase-to-phase and longitudinal insulation
standard withstand voltage tests for
equipment in range II
Figure
Tables
Annex A
Annex ZA (normative) Normative references to
international publications with their
corresponding European publications
DevelopmentNote |
Supersedes DIN IEC 60071-1. (11/2006)
|
DocumentType |
Standard
|
PublisherName |
Verband Deutscher Elektrotechniker
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 60071-1:2006 | Identical |
NF EN 60071-1 : 2006 AMD 1 2010 | Identical |
BS EN 60071-1 : 2006 | Identical |
VDE 0111-1 : 2010 | Corresponds |
NBN EN 60071-1 : 2006 AMD 1 2010 | Identical |
I.S. EN 60071-1:2006 | Identical |
EN 60071-1:2006/A1:2010 | Identical |
IEC 60071-1:2006+AMD1:2010 CSV | Identical |
SN EN 60071-1 : 2006 + A1 2010 | Identical |
DIN EN 61954 : 2018 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011 + A1:2013 + A2:2017) |
VDE 0553-100 : 2018 | STATIC VAR COMPENSATORS (SVC) - TESTING OF THYRISTOR VALVES (IEC 61954:2011 + A1:2013 + A2:2017) |
VDE 0160 : 1998-04 | ELECTRONIC EQUIPMENT FOR USE IN POWER INSTALLATIONS |
VDE 0674-1 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
VDE 0682-412 : 2001 AMD 1 2003 | LIVE WORKING - VOLTAGE DETECTORS - PART 2: RESISTIVE TYPE TO BE USED FOR VOLTAGES OF 1 KV TO 36 KV A.C. |
DIN EN 61243-2 : 2001 AMD 2 2003 | LIVE WORKING - VOLTAGE DETECTORS - PART 2: RESISTIVE TYPE TO BE USED FOR VOLTAGES OF 1 KV TO 36 KV A.C. |
DIN VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
VDE 0276-634 : 1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
VDE 0414-2 : 99 AMD 1 2001 | INSTRUMENT TRANSFORMERS - PART 1: INDUCTIVE VOLTAGE TRANSFORMERS |
VDE 0446-7 : 1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC INSULATORS FOR A.C. SYSTEMS - CHARACTERISTICS OF INSULATOR UNITS OF THE LONG ROD TYPE |
VDE 0414-44-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
VDE 0276-635 : 1999 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
DIN EN 60168 : 2001-12 | TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV |
VDE 0560-430 : 1998 | INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS |
DIN EN 60433 : 1999 | INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC INSULATORS FOR A.C. SYSTEMS - CHARACTERISTICS OF INSULATOR UNITS OF THE LONG ROD TYPE |
DIN VDE 0276-634 : 1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
DIN EN 60044-7 : 2000 | INSTRUMENT TRANSFORMERS - PART 7: ELECTRONIC VOLTAGE TRANSFORMERS |
VDE 0101 : 2000 | POWER INSTALLATIONS EXCEEDING 1 KV |
DIN VDE 0276-635 : 1999 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
DIN EN 60660 : 2000 | INSULATORS - TESTS ON INDOOR POST INSULATORS OF ORGANIC MATERIAL FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV UP TO BUT NOT INCLUDING 300 KV |
KTA 3403 : 2015(R2017) | CABLE PENETRATIONS THROUGH THE REACTOR CONTAINMENT VESSEL OF NUCLEAR POWER PLANTS |
DIN EN 61642 : 1998 | INDUSTRIAL A.C. NETWORKS AFFECTED BY HARMONICS - APPLICATION OF FILTERS AND SHUNT CAPACITORS |
DIN EN 60071-2 : 1997 | INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE |
VDE 0441-3 : 2000-12 | INSULATORS - TESTS ON INDOOR POST INSULATORS OF ORGANIC MATERIAL FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV UP TO BUT NOT INCLUDING 300 KV |
VDE 0441-5 : 2002 | COMPOSITE STRING INSULATOR UNITS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE GREATER THAN 1 KV - DIMENSIONAL AND ELECTRICAL CHARACTERISTICS |
VDE 0111-2 : 1997 | INSULATION CO-ORDINATION - PART 2: APPLICATION GUIDE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.