DIN EN 50392 : 2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

GENERIC STANDARD TO DEMONSTRATE THE COMPLIANCE OF ELECTRONIC AND ELECTRICAL APPARATUS WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ)

Superseded date

01-09-2008

Superseded by

DIN EN 62311 : 2008

Published date

12-01-2013

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Terms, definitions
4 Compliance criteria
5 Assessment methods
6 Evaluation of compliance to limits
7 Applicability of compliance assessment methods
   7.1 Characteristics and parameters of apparatus to be
       considered
   7.2 List of possible assessment methods
   7.3 Decision tree (Assessment applicability table versus
       equipment characteristics)
       7.3.1 Generic procedure for assessment of apparatus
8 Sources with multiple frequencies
   8.1 Harmonics, pulses and non-sinusoidal fields
       8.1.1 Introduction
       8.1.2 Frequency range from 1 Hz - 10 MHz
       8.1.3 Frequency range from 100 KHz - 300 GHz
9 Assessment report
   9.1 General
   9.2 Items to be recorded in the assessment report
       9.2.1 Assessment method
       9.2.2 Presentation of the results
       9.2.3 Equipment using external antennas
10 Information to be supplied with the apparatus
Annex A (informative) Field calculation
  A.1 Purpose
  A.2 Far-field region
  A.3 Radiating near-field region
  A.4 Reactive near field region
      A.4.1 Typical antenna examples
      A.4.2 Discussion
      A.4.3 Conclusion
  A.5 Example of calculations within field regions at 900 MHz
Annex B (informative) SAR compliance assessment
  B.1 Whole body SAR
      B.1.1 Introduction
      B.1.2 Whole-body SAR implicit compliance
  B.2 Localised SAR
Annex C (informative) Information for numerical modelling
  C.1 Introduction
  C.2 Anatomical models
      C.2.1 The Visible Human Project
      C.2.2 'MEET Man'
      C.2.3 'Hugo'
      C.2.4 'Norman'
      C.2.5 University of Utah
      C.2.6 University of Victoria
  C.3 Simpler, homogeneous body models
  C.4 Electrical properties of tissue
  C.5 Calculation of the induced electric current density
  C.6 Representation of measured magnetic field distributions
      by equivalent sources
  C.7 Induced current densities for different sizes of
      prolate spheroid
      C.7.1 Uniform magnetic field source
      C.7.2 Modelling results for a 60 cm by 30 cm Prolate
            Spheroid
      C.7.3 Modelling results for a 120 cm by 60 cm Prolate
            Spheroid
      C.7.4 Modelling results for a 180 cm by 80 cm Prolate
            Spheroid
  C.8 Induced current densities for the human body and hand
      (informative)
      C.8.1 Uniform magnetic field
      C.8.2 Non-uniform magnetic fields and calculation of
            the coupling factor k
  C.9 References
Annex D (informative) Measurements of physical properties and
                      body currents
  D.1 Measurement of body current
  D.2 Measurement of induced body currents
  D.3 Measurement of contact current
  D.4 Measurement of touch voltage
  D.5 References
Annex E (informative) SAR
  E.1 Specific Absorption Rate (SAR) measurement procedures
      E.1.1 Electric field measurement procedures
      E.1.2 Temperature measurement procedures
      E.1.3 Calorimetric measurement procedures
Annex F (informative) Measurement of E & H field
  F.1 Measurement of external electromagnetic fields
      F.1.1 General considerations
      F.1.2 Equivalent field strength
Annex G (informative) Source modelling
  G.1 Numerical modelling
      G.1.1 Description of available methods
  G.2 Field strength calculations
  G.3 Specific absorption rate calculations
Bibliography

This standard is included in DIN VDE Handbook 503. Provides the demonstration of the compliance of such apparatus with the basic restrictions or reference levels on exposure of the general public related to electric, magnetic, electromagnetic fields and induced and contact current. Applies to electronic and electrical apparatus for which no dedicated product or product family standard regarding human exposure to electromagnetic fields applies.

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy

Standards Relationship
I.S. EN 50392:2004 Identical
NEN EN 50392 : 2004 Identical
NF EN 50392 : 2004 Identical
UNE-EN 50392:2005 Identical
NBN EN 50392 : 2005 Identical
VDE 0848-392 : 2004 Corresponds
EN 50392:2004 Identical
BS EN 50392:2004 Identical
VDE 0848-392 : 2004 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.