GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
Hardcopy , PDF
German, English
01-01-2003
Foreword
1 Scope
2 Normative references
3 Definitions
3.1 Organisational terms
3.2 Technical terms
3.3 General terms
4 Brief overall project description
4.1 Role and organisation of purchaser
4.2 Site location
4.3 Equipment task
4.4 Equipment to be purchased
4.5 Control and instrumentation
4.6 Electrical supplies and other services
4.7 Other interfaces
4.8 Project programe
4.9 Equipment identification systems
5 Extent of supply
6 Terminal points
7 Operational requirements
7.1 Operating environment
7.2 Manning levels
7.3 Normal operation
7.4 Operating hours
7.5 Start-up and shut-down
7.6 Abnormal conditions
7.7 Further operational requirements
8 Life expectancy
8.1 Design life
8.2 Components requiring periodic maintenance
9 Performance requirements
9.1 Duty
9.2 Performance
9.3 Equipment margins
9.4 Availability
9.5 Levels of component redundancy
9.6 Further performance requirements
10 Design and fabrication
10.1 Specific equipment features
10.2 Design justification
10.3 Material selection
10.4 Safety
10.5 Interchangeability
10.6 Fabrication methods
11 Maintenance requirements
11.1 Planned maintenance
11.2 Personnel safety
11.3 Requirements for access
11.4 Lifting requirements
11.5 Special tools
11.6 Test equipment
11.7 Spare parts strategy
11.8 Special precautions
12 Technical documentation requirements
12.1 Tender documentation
12.2 Contract documentation
13 Applicable legislation, regulations, standards and
further requirements
13.1 Legislation and regulations
13.2 Standards
13.3 Further requirements
14 Evaluation criteria
14.1 General
14.2 Technical criteria
15 Quality measures
15.1 General
15.2 Approvals procedure
15.3 Inspection requirements
15.4 Non-conformity
16 Site factors
16.1 Access
16.2 Facilities
16.3 Site specific requirements
17 Verification of specified performance
17.1 General
17.2 Works tests
17.3 Tests during installation and commissioning
17.4 Technical conditions for trial run
17.5 Functional and performance tests
Annex A (informative) Bibliography
Specifies guidance on writing the technical specification for the procurement of switchgear and controlgear for use in electricity generating stations (power stations). This Guide for procurement is not applicable to equipment for use in the nuclear reactor plant area of nuclear power stations.
DevelopmentNote |
Supersedes DIN EN 45511 (12/2003)
|
DocumentType |
Standard
|
Pages |
35
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Current
|
Standards | Relationship |
NS EN 45510-2-7 : 1ED 2002 | Identical |
EN 45510-2-7:2002 | Identical |
SN EN 45510-2-7 : 2002 | Identical |
BS EN 45510-2-7:2002 | Identical |
UNE-EN 45510-2-7:2004 | Identical |
NF EN 45510-2-7 : 2002 | Identical |
NEN EN 45510-2-7 : 2002 | Identical |
I.S. EN 45510-2-7:2002 | Identical |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
EN 60517:1996/A11:1999 | GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
EN 60129:1994/A2:1996 | ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES |
HD 464 : S1 AMD 5 2002 | DRY-TYPE POWER TRANSFORMERS |
EN 60265-2:1993/A2:1998 | HIGH-VOLTAGE SWITCHES - HIGH-VOLTAGE SWITCHES FOR RATED VOLTAGES OF 52 KV AND ABOVE |
EN 61264:1998/corrigendum:2000 | CERAMIC PRESSURIZED HOLLOW INSULATORS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
EN 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
EN 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
HD 538.1 S1:1992/AC:2011 | THREE-PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 24 KV |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
HD 597 S1:1992/corrigendum:1992 | COUPLING CAPACITORS AND CAPACITOR DIVIDERS |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
HD 625.1 : 200S1 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PRINCIPLES, REQUIREMENTS AND TESTS |
IEC 60939-1:2010 | Passive filter units for electromagnetic interference suppression - Part 1: Generic specification |
EN 45510-8-1:1998 | Guide for procurement of power station equipment - Part 8-1: Control and instrumentation |
EN 61166:1993 | High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
IEC 60939-2:2005 | Passive filter units for electromagnetic interference suppression - Part 2: Sectional specification - Passive filter units for which safety tests are appropriate - Test methods and general requirements |
EN 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
IEC 60949:1988 | Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
EN 61100:1992 | Classification of insulating liquids according to fire point and net calorific value |
IEC 60353:1989 | Line traps for a.c. power systems |
EN 60439-3:1991/corrigendum:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 3: PARTICULAR REQUIREMENTS FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES INTENDED TO BE INSTALLED IN PLACES WHERE UNSKILLED PERSONS HAVE ACCESS FOR THEIR USE - DISTRIBUTION BOARDS |
EN 61259 : 1994 | GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES 72,5 kV AND ABOVE - REQUIREMENTS FOR SWITCHING OF BUS-CHARGING CURRENTS BY DISCONNECTORS |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
IEC 60044-3:2002 | Instrument transformers - Part 3: Combined transformers |
EN 60099-1:1994/A1:1999 | SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
EN 60044-6 : 1999 | INSTRUMENT TRANSFORMERS - REQUIREMENTS FOR PROTECTIVE CURRENT TRANSFORMERS FOR TRANSIENT PERFORMANCE |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
EN 60255-6 : 94 AC 95 | ELECTRICAL RELAYS - MEASURING RELAYS AND PROTECTION EQUIPMENT |
EN 45510-8-1:1998 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 8-1: CONTROL AND INSTRUMENTATION |
EN 60947-3:2009/A2:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015) |
EN 60617-7:1996 | Graphical symbols for diagrams - Part 7: Switchgear, controlgear and protective devices |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 60060-2:2011 | High-voltage test techniques - Part 2: Measuring systems |
EN 60447:2004 | Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
EN 60298:1996/A11:1999 | A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
EN 60470:2000/corrigendum Jun. 2000 | HIGH-VOLTAGE ALTERNATING CURRENT CONTACTORS AND CONTACTOR-BASED MOTOR STARTERS |
EN 60439-4:2004 | Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS) |
HD 578 : 200S1 | CHARACTERISTICS OF INDOOR AND OUTDOOR POST INSULATORS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1000 V |
EN 61129:1994/A1:1995 | ALTERNATING CURRENT EARTHING SWITCHES - INDUCED CURRENT SWITCHING |
IEC 60291:1969 | Fuse definitions |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
EN 60947-4-1 : 2010 AMD 1 2012 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012) |
HD 554 : 200S1 | VOLTAGE TRANSFORMERS |
HD 566 : 200S1 | THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION |
EN 60865-1:2012 | Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
EN 60265-1:1998 | High-voltage switches - Part 1: Switches for rated voltages above 1 kV and less than 52 kV |
EN 60269-2:1995/A2:2002 | LOW-VOLTAGE FUSES - SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) |
EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013) |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
EN 60427:2000 | Synthetic testing of high-voltage alternating current circuit-breakers |
EN 60622:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
EN 60044-1:1999/A2:2003 | INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS |
EN 60282-1:2009/A1:2014 | HIGH-VOLTAGE FUSES - PART 1: CURRENT-LIMITING FUSES (IEC 60282-1:2009) |
EN ISO 8402 : 1995 | QUALITY MANAGEMENT AND QUALITY ASSURANCE - VOCABULARY |
EN 60420:1993 | High-voltage alternating current switch-fuse combinations |
EN 60947-6-1:2005/A1:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT (IEC 60947-6-1:2005/A1:2013) |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
EN 60947-7-1:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS |
EN 60644:2009 | Specification for high-voltage fuse-links for motor circuit application |
EN 50014:1997/A2:1999 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.