DIN EN 14314:2016-03
Current
The latest, up-to-date edition.
THERMAL INSULATION PRODUCTS FOR BUILDING EQUIPMENT AND INDUSTRIAL INSTALLATIONS - FACTORY MADE PHENOLIC FOAM (PF) PRODUCTS - SPECIFICATION
Hardcopy , PDF
English, German
01-01-2016
National foreword
European foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols, units and
abbreviated terms
4 Requirements
5 Test methods
6 Designation code
7 Assessment and Verification of the
Constancy of Performance (AVCP)
8 Marking and labeling
Annex A (normative) - Factory production control
Annex B (normative) - Determination of the aged
value of thermal conductivity
Annex C (normative) - Determination of minimum
service temperature
Annex D (informative) - Additional properties
Annex ZA (informative) - Clauses of this European
Standard addressing the provisions of the EU
Construction Products Regulation
Bibliography
Describes the requirements for factory made phenolic foam products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature in the range of approximately -200 degrees C to +120 degrees C.
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Current
|
Standards | Relationship |
EN 14314:2015 | Identical |
DIN 4140:2014-04 | Insulation work on industrial installations and building equipment - Execution of thermal and cold insulations |
VDI 2055 Blatt 2:2013-10 | Thermal insulation of heated and refrigerated operational installations in the industry and in the building services - Technical basics for the verification of properties of insulating materials |
VDI 2055 Blatt 1:2008-09 | Thermal insulation of heated and refrigerated operational installations in the industry and the building services - Calculation rules |
DIN 4108-4:2016-07 (Draft) | THERMAL INSULATION AND ENERGY ECONOMY IN BUILDINGS - PART 4: HYGROTHERMAL DESIGN VALUES |
DIN 4140:1996-11 | INSULATION WORK ON INDUSTRIAL INSTALLATIONS AND BUILDING EQUIPMENT - EXECUTION OF THERMAL AND COLD INSULATIONS |
ISO 9229:2007 | Thermal insulation Vocabulary |
EN 12667:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance |
ISO 13787:2003 | Thermal insulation products for building equipment and industrial installations Determination of declared thermal conductivity |
EN 14706:2012 | Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature |
EN 12085:2013 | Thermal insulating products for building applications - Determination of linear dimensions of test specimens |
EN 14509:2013 | Self-supporting double skin metal faced insulating panels - Factory made products - Specifications |
EN 13468:2001 | Thermal insulating products for building equipment and industrial installations - Determination of trace quantities of water soluble chloride, fluoride, silicate, sodium ions and pH |
EN 1607:2013 | Thermal insulating products for building applications - Determination of tensile strength perpendicular to faces |
EN 1606:2013 | Thermal insulating products for building applications - Determination of compressive creep |
EN 1608:2013 | Thermal insulating products for building applications - Determination of tensile strength parallel to faces |
EN 13471:2001 | Thermal insulating products for building equipment and industrial installations - Determination of the coefficient of thermal expansion |
EN 12939:2000 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Thick products of high and medium thermal resistance |
EN ISO 8497:1996 | Thermal insulation - Determination of steady-state thermal transmission properties of thermal insulation for circular pipes (ISO 8497:1994) |
EN ISO 9229:2007 | Thermal insulation - Vocabulary (ISO 9229:2007) |
EN ISO 4590:2016 | Rigid cellular plastics - Determination of the volume percentage of open cells and of closed cells (ISO 4590:2016) |
EN 13469:2012 | Thermal insulating products for building equipment and industrial installations - Determination of water vapour transmission properties of preformed pipe insulation |
EN 824:2013 | Thermal insulating products for building applications - Determination of squareness |
ISO 4590:2016 | Rigid cellular plastics Determination of the volume percentage of open cells and of closed cells |
ISO 11925-2:2010 | Reaction to fire tests Ignitability of products subjected to direct impingement of flame Part 2: Single-flame source test |
EN 825:2013 | Thermal insulating products for building applications - Determination of flatness |
EN 823:2013 | Thermal insulating products for building applications - Determination of thickness |
ISO 8497:1994 | Thermal insulation — Determination of steady-state thermal transmission properties of thermal insulation for circular pipes |
EN ISO 13787:2003 | Thermal insulation products for building equipment and industrial installations - Determination of declared thermal conductivity (ISO 13787:2003) |
EN 13166:2012+A2:2016 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
EN 13470:2001 | Thermal insulating products for building equipment and industrial installations - Determination of the apparent density of preformed pipe insulation |
EN 13238:2010 | Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
EN 1602:2013 | Thermal insulating products for building applications - Determination of the apparent density |
EN 12090:2013 | Thermal insulating products for building applications - Determination of shear behaviour |
EN 1604:2013 | Thermal insulating products for building applications - Determination of dimensional stability under specified temperature and humidity conditions |
EN 14707:2012 | Thermal insulating products for building equipment and industrial installations - Determination of maximum service temperature for preformed pipe insulation |
EN 12089:2013 | Thermal insulating products for building applications - Determination of bending behaviour |
ISO 10456:2007 | Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
ISO 65:1981 | Carbon steel tubes suitable for screwing in accordance with ISO 7-1 |
EN 12429:1998 | Thermal insulating products for building applications - Conditioning to moisture equilibrium under specified temperature and humidity conditions |
EN 1609:2013 | Thermal insulating products for building applications - Determination of short term water absorption by partial immersion |
EN 826:2013 | Thermal insulating products for building applications - Determination of compression behaviour |
EN 15715:2009 | Thermal insulation products - Instructions for mounting and fixing for reaction to fire testing - Factory made products |
EN 12086:2013 | Thermal insulating products for building applications - Determination of water vapour transmission properties |
EN 13172:2012 | Thermal insulation products - Evaluation of conformity |
EN 822:2013 | Thermal insulating products for building applications - Determination of length and width |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.