DIN 18195-9:2010-05
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
WATER-PROOFING OF BUILDINGS - PART 9: PENETRATIONS, TRANSITIONS, CONNECTIONS AND ENDINGS
Hardcopy , PDF
01-07-2017
DIN 18535-2:2015-06 (Draft)
DIN 18533-1:2015-12 (Draft)
DIN 18533-3:2015-12 (Draft)
DIN 18531-1:2016-06 (Draft)
DIN 18532-3:2016-05 (Draft)
DIN 18532-1:2016-05 (Draft)
DIN 18534-1:2015-07 (Draft)
DIN 18532-6:2016-05 (Draft)
DIN 18535-1:2015-06 (Draft)
DIN 18534-3:2015-07 (Draft)
DIN 18532-4:2016-05 (Draft)
DIN 18531-2:2016-06 (Draft)
DIN 18535-3:2015-06 (Draft)
DIN 18195:2015-06 (Draft)
DIN 18533-2:2015-12 (Draft)
DIN 18532-2:2016-05 (Draft)
DIN 18534-2:2015-07 (Draft)
DIN 18531-4:2016-06 (Draft)
DIN 18534-4:2016-10 (Draft)
DIN 18531-3:2016-06 (Draft)
DIN 18532-5:2016-05 (Draft)
DIN 18531-5:2016-06 (Draft)
German
01-01-2010
Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Begriffe
4 Anforderungen
4.1 Dichtheit
4.2 Lagesicherheit
4.3 Dauerhaftigkeit
5 Bauliche Erfordernisse
5.1 Allgemeines
5.2 Mindestabstände
5.3 Zu wartende Bauteile
5.4 Konstruktive Gestaltung von aufgehenden Bauteilen
für Abschlüsse bei Abdichtungen nach DIN 18195-4,
DIN 18195-5 und DIN 18195-6
5.4.1 Allgemeine Anforderungen
5.4.2 Gebäudesockel für Abschlüsse von Abdichtungen
nach DIN 18195-4 und DIN 18195-6:2000-08,
Abschnitt 9
5.4.3 Abschlüsse bei Abdichtungen nach DIN 18195-5
5.4.4 Anordnung der Abdichtung bei Türschwellen
6 Ausführung von Anschlüssen an Durchdringungen,
Übergängen und Abschlüssen
6.1 Anschlüsse und Übergänge
6.1.1 Bei Abdichtungen gegen Bodenfeuchte
(Kapillarwasser, Haftwasser) und nichtstauendes
Sickerwasser an Bodenplatten und Wänden nach DIN
18195-5
6.1.2 Bei Abdichtungen gegen nichtdrückendes Wasser
auf Deckenflächen und in Nassräumen nach DIN
18195-5
6.1.3 Bei Abdichtungen gegen von aussen drückendes
Wasser und zeitweise aufstauendes Sickerwasser
nach DIN 18195-6
6.2 Abschlüsse bei über Geländeoberfläche bzw. Nutzbelag
oder Begrünung hochgeführten Abdichtungen
6.2.1 Vor Wasserbeanspruchung geschützt liegende
Abschlüsse
6.2.2 Wasserbeanspruchte Abschlüsse
6.3 Abschlüsse unter Geländeoberfläche
6.3.1 Erdüberschüttete Bauwerke
6.3.2 Bauwerke mit Abdichtungen gegen von aussen
drückendes Wasser nach DIN 18195-6:2000-08,
Abschnitt 8
7 Ausbildung und Anordnung von Einbauteilen
7.1 Allgemeines
7.2 Klebeflansche, Anschweissflansche, Manschetten
7.3 Schellen
7.4 Klemmschienen
7.5 Klemmprofile
7.6 Los- und Festflanschkonstruktionen
7.7 Telleranker
This standard is included in DIN Handbook 110 and 129.
DocumentType |
Standard
|
Pages |
19
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
SupersededBy |
|
DIN HDBK 129 : 12ED 2015 | |
DIN 18195-3:2011-12 | WATER-PROOFING OF BUILDINGS - PART 3: REQUIREMENTS OF THE GROUND AND WORKING PROPERTIES OF MATERIALS |
DIN 18195-4:2011-12 | WATER-PROOFING OF BUILDINGS - PART 4: WATERPROOFING AGAINST GROUND MOISTURE (CAPILLARY WATER, RETAINED WATER) AND NON-ACCUMULATING SEEPAGE WATER UNDER FLOOR SLABS ON WALLS, DESIGN AND EXECUTION |
DIN 18195-10:2011-12 | WATER-PROOFING OF BUILDINGS - PART 10: PROTECTIVE LAYERS AND PROTECTIVE MEASURES |
DIN 18195-6:1983-08 | WATERPROOFING OF BUILDINGS AND STRUCTURES - WATERPROOFING AGAINST WATER THAT EXERTS HYDROSTATIC PRESSURE FROM THE OUTSIDE - DESIGN AND WORKMANSHIP |
DIN 18195-2:1983-08 | WATERPROOFING OF BUILDINGS AND STRUCTURES - MATERIALS |
DIN 18195-4:1983-08 | WATERPROOFING OF BUILDINGS AND STRUCTURES - DAMP-PROOFING AGAINST MOISTURE FROM THE GROUND - DESIGN AND WORKMANSHIP |
DIN 18195-1:1983-08 | WATERPROOFING OF BUILDINGS AND STRUCTURES - GENERAL, TERMINOLOGY |
DIN 18195-8:1983-08 | WATERPROOFING OF BUILDINGS AND STRUCTURES - WATERPROOFING OVER MOVEMENT JOINTS |
DIN 18195-9:1986-12 | WATERPROOFING OF BUILDINGS AND STRUCTURES - PENETRATIONS, TRANSITIONS, CLOSURES |
DIN 18195-3:1983-08 | WATERPROOFING OF BUILDINGS AND STRUCTURES - PROCESSING OF MATERIALS |
DIN 18195-5:1984-02 | WATERPROOFING OF BUILDINGS AND STRUCTURES - WATERPROOFING AGAINST WATER THAT EXERTS NO HYDROSTATIC PRESSURE - DESIGN AND WORKMANSHIP |
DIN 18195-7:1989-06 | WATERPROOFING OF BUILDINGS AND STRUCTURES - WATERPROOFING SHEETING SUBJECTED TO HYDROSTATIC PRESSURE FROM THE INSIDE - DESIGN AND WORKMANSHIP |
VDI/BV-BS 6000 Blatt 1.1:2012-02 | Provision and installation of sanitary facilities - Generic aspects and systems; Prefabricated sanitary modules (prefabricated sanitary rooms, installation systems) |
VDI 6004 Blatt 1:2006-06 | Protection of Building Services - Flood - Buildings, installations, equipment |
DIN HDBK 110 : 12ED 2016 | |
DIN 1988-200:2012-05 | Codes of practice for drinking water installations - Part 200: Installation Type A (closed system) - Planning, components, apparatus, materials; DVGW code of practice |
DIN 18195-1:2011-12 | WATERPROOFING OF BUILDINGS - PART 1: PRINCIPLES, DEFINITIONS, ATTRIBUTION OF WATERPROOFING TYPES |
DIN 18195-6:2011-12 | WATER-PROOFING OF BUILDINGS - PART 6: WATER-PROOFING AGAINST OUTSIDE PRESSING WATER AND ACCUMULATING SEEPAGE WATER, DESIGN AND EXECUTION |
DIN 18195-8:2011-12 | WATER-PROOFING OF BUILDINGS - PART 8: WATER-PROOFING OVER JOINTS FOR MOVEMENTS |
KTA 2501 : 2015(R2017) | STRUCTURAL WATERPROOFING OF NUCLEAR POWER PLANTS |
DIN 18195-5:2011-12 | WATER-PROOFING OF BUILDINGS - PART 5: WATER-PROOFING AGAINST NON-PRESSING WATER ON FLOORS AND IN WET AREAS, DESIGN AND EXECUTION |
DIN 18014:2014-03 | Foundation earth electrode - Planning, execution and documentation |
DIN 1988-7:2004-12 | CODES OF PRACTICE FOR DRINKING WATER INSTALLATIONS (TRWI) - PART 7: PREVENTION OF CORROSION DAMAGE AND CALCAREOUS DEPOSIT FORMATION - DVGW CODE OF PRACTICE |
DIN HDBK 310 : 2ED 2001 | BAUPHYSIK 2 - NORMEN FUER DAS STUDIUM - FEUCHTESCHUTZ, LUEFTUNG, WAERMEBEDARFSERMITTLUNG, WAERMESCHUTZ |
DIN 18195-2:2009-04 | WATER-PROOFING OF BUILDINGS - PART 2: MATERIALS |
DIN 18195-10:1983-08 | WATERPROOFING OF BUILDINGS AND STRUCTURES - PROTECTIVE LAYERS AND PROTECTIVE MEASURES |
DIN EN 1253-2:2015-03 | GULLIES FOR BUILDINGS - PART 2: ROOF DRAINS AND FLOOR GULLIES WITHOUT TRAP |
DIN EN 1253-4:2016-07 | GULLIES FOR BUILDINGS - PART 4: ACCESS COVERS |
DIN 18195-3:2011-12 | WATER-PROOFING OF BUILDINGS - PART 3: REQUIREMENTS OF THE GROUND AND WORKING PROPERTIES OF MATERIALS |
DIN 18531:1991-09 | WATER-PROOFING OF ROOFS - CONCEPTS, REQUIREMENTS, DESIGN PRINCIPLES |
EN 1253-4:2016 | Gullies for buildings - Part 4: Access covers |
DIN 18195-7:2009-07 | WATER-PROOFING OF BUILDINGS - PART 7: WATER-PROOFING AGAINST PRESSING WATER FROM THE INSIDE, DIMENSIONING AND EXECUTION |
DIN 18195-10:2011-12 | WATER-PROOFING OF BUILDINGS - PART 10: PROTECTIVE LAYERS AND PROTECTIVE MEASURES |
DIN 52129:2014-11 | UNCOATED BITUMEN SATURATED SHEETING - DEFINITION, DESIGNATION, REQUIREMENTS |
DIN 18195-4:2011-12 | WATER-PROOFING OF BUILDINGS - PART 4: WATERPROOFING AGAINST GROUND MOISTURE (CAPILLARY WATER, RETAINED WATER) AND NON-ACCUMULATING SEEPAGE WATER UNDER FLOOR SLABS ON WALLS, DESIGN AND EXECUTION |
DIN EN 1253-1:2015-03 | GULLIES FOR BUILDINGS - PART 1: TRAPPED FLOOR GULLIES WITH A DEPTH WATER SEAL OF AT LEAST 50 MM |
EN 1253-2:2015 | Gullies for buildings - Part 2: Roof drains and floor gullies without trap |
DIN 18195-1:2011-12 | WATERPROOFING OF BUILDINGS - PART 1: PRINCIPLES, DEFINITIONS, ATTRIBUTION OF WATERPROOFING TYPES |
DIN 18195-2:2009-04 | WATER-PROOFING OF BUILDINGS - PART 2: MATERIALS |
DIN 18195-5:2011-12 | WATER-PROOFING OF BUILDINGS - PART 5: WATER-PROOFING AGAINST NON-PRESSING WATER ON FLOORS AND IN WET AREAS, DESIGN AND EXECUTION |
EN 1253-3:2016 | Gullies for buildings - Part 3: Evaluation of conformity |
DIN 18195-6:2011-12 | WATER-PROOFING OF BUILDINGS - PART 6: WATER-PROOFING AGAINST OUTSIDE PRESSING WATER AND ACCUMULATING SEEPAGE WATER, DESIGN AND EXECUTION |
DIN 18800-7:2008-11 | STEEL STRUCTURES - PART 7: EXECUTION AND CONSTRUCTER'S QUALIFICATION |
DIN EN 1253-3:2016-09 | GULLIES FOR BUILDINGS - PART 3: EVALUATION OF CONFORMITY |
DIN 18195-8:2011-12 | WATER-PROOFING OF BUILDINGS - PART 8: WATER-PROOFING OVER JOINTS FOR MOVEMENTS |
DIN V 18197:2005-10 | SEALING OF JOINTS IN CONCRETE WITH WATER STOPS |
EN 1253-1:2015 | Gullies for buildings - Part 1: Trapped floor gullies with a depth water seal of at least 50 mm |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.