FOREWORD
1 Scope and object
2 Normative references
3 Definitions and abbreviations
3.1 Definitions
3.2 Abbreviations
4 Lower layer profile structure
4.1 Physical layer
4.2 MAC sublayer
5 Physical layer specification
5.1 Modulation
5.1.1 Purpose
5.1.2 The multicarrier modulation (MCM) principle
5.2 Physical layer data format
5.2.1 Purpose
5.2.2 Transmission method, overview
5.2.3 Configuration parameters
5.2.4 PHY PDU format, CRC encoding and padding
5.2.5 Convolutional encoding
5.2.6 Segmentation and interleaving
5.2.7 Preamble
5.2.8 Modulation
5.3 PHY services
5.3.1 PHY to MAC interface
6 MAC sublayer protocol specification
6.1 Overview
6.1.1 MAC communication network architecture
6.1.2 Features of the MAC sublayer
6.2 Transmission procedures
6.3 MAC services
6.3.1 MAC to LLC interface
6.3.2 MAC layer management interface
6.4 MAC PDU format
6.4.1 MAC control field
6.4.2 Address field
6.4.3 LLC PDU
6.5 MAC addresses
6.6 Used MAC PDUs
6.6.1 Information PDU
6.6.2 Repetition control PDU
6.7 MAC invalid PDU
6.8 MAC procedures
6.8.1 MACphy procedures
6.8.2 MACrore procedures
6.9 MAC timer values
6.10 MAC state transition diagrams/tables
6.10.1 Startup
6.10.2 MAC sublayer
6.10.3 Non-initiator MAC sublayer
Figures
Tables
Defines the requirements of the multicarrier modulation (MCM) approach which incorporates the services provided by the physical layer entity and the MAC sublayer with the purpose of building up a set of standards for effective communication on MV and LV network for distribution line carrier (DLC) systems, in the context of IEC 61334-1-1.
Committee |
PEL/57
|
DevelopmentNote |
Supersedes 00/202686 DC. (05/2002)
|
DocumentType |
Standard
|
Pages |
40
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Is a technical specification describing the requirements of the multicarrier modulation approach which incorporates the services provided by the physical layer entity and the MAC sublayer with the purpose of building up a set of standards for effective communication on MV and LV network for distribution line carrier systems, in the context of IEC 61334-1-1.
This publication is of high relevance for Smart Grid.
Standards | Relationship |
IEC TS 61334-5-4:2001 | Identical |
IEC 61334-3-1:1998 | Distribution automation using distribution line carrier systems - Part 3-1: Mains signalling requirements - Frequency bands and output levels |
IEC 61334-4-1:1996 | Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 1: Reference model of the communication system |
IEC TR 61334-1-1:1995 | Distribution automation using distribution line carrier systems - Part 1: General considerations - Section 1: Distribution automation system architecture |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.