CSA E61347.2.3 : 2003 : INC : UPD 1 : 2012 : R200800
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
LAMP CONTROLGEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. SUPPLIED ELECTRONIC BALLASTS FOR FLUORESCENT LAMP
Hardcopy , PDF
12-07-2021
English
01-01-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions
15 Protection of associated components
16 Abnormal conditions
17 Behaviour of the ballast at the end of lamp life
18 Construction
19 Creepage distances and clearances
20 Screws, current-carrying parts and connections
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
Annexes
Annex A (normative) - Test to establish whether a conductive
part is a live part which may cause an electric shock
Annex B (normative) - Particular requirements for thermally
protected lamp controlgear
Annex C (normative) - Particular requirements for electronic
lamp controlgear with means of protection against
overheating
Annex D (normative) - Requirements for carrying out the heating
tests of thermally protected lamp controlgear ballasts
Annex E (normative) - Use of constant S other than 4500 in
t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of the
values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Measurement of high-frequency leakage
current
Annex J (normative) - Particular additional safety requirements
for a.c./d.c. supplied electronic ballasts for emergency
lighting
Annex K (informative) - Components used in the asymmetric
pulse test circuit
Defines particular safety requirements for electronic ballasts that are: a) designed to be installed on branch circuits not exceeding 600 V nominal between conductors and used in accordance with the rules of the Canadian Electrical Code, Part I, with operating frequencies deviating from the supply frequency; and b) associated with fluorescent lamps as specified in IEC 60081 and IEC 60901 or ANSI C78.81 and ANSI C78.901 and other fluorescent lamps for high-frequency operation.
DevelopmentNote |
Amendment 1 is available separately. See CSA E61347.2.3A. (12/2005) Supersedes CSA E928. (08/2012)
|
DocumentType |
Standard
|
Pages |
66
|
ProductNote |
Reconfirmed EN
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
ANSI C82.11-2017 | American National Standard for Lamp Ballasts—High Frequency Fluorescent Lamp Ballasts |
ANSI C78.81:2016 | American National Standard for Electric Lamps—Double-Capped Fluorescent Lamps—Dimensional and Electrical Characteristics |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
IEC 61347-2-7:2011+AMD1:2017 CSV | Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained) |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
ANSI C78.901:2016 | American National Standard for Electric Lamps—Single-Based Fluorescent Lamps—Dimensional and Electrical Characteristics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.