CSA E598.1 : 2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS
Hardcopy , PDF
01-07-2002
English
Foreword
Section 0: General Introduction
0.1 Scope and object
0.2 Normative references
0.3 General requirements and verification
0.4 General test requirements
0.5 Components of luminaires
0.6 List of sections of part 2
Section 1: Definitions
1.1 General
1.2 Definitions
Section 2: Classification of luminaires
2.1 General
2.2 Classification according to type of
protection against electric shock
2.3 Classification according to degree
of protection against ingress of dust,
solid objects and moisture
2.4 Classification according to material
of supporting surface for which the
luminaire is designed
Section 3: Marking
3.1 General
3.2 Marking on luminaires
3.3 Additional information
3.4 Test of marking
Section 4: Construction
4.1 General
4.2 Replaceable components
4.3 Wireways
4.4 Lampholders
4.5 Starter holders
4.6 Terminal blocks
4.7 Terminals and supply connections
4.8 Switches
4.9 Insulating lines and sleeves
4.10 Double and reinforced insulation
4.11 Electrical connections and current
carrying parts
4.12 Screws and connections (mechanical)
and glands
4.13 Mechanical strength
4.14 Suspensions and adjusting devices
4.15 Flammable materials
4.16 Luminaires marked with symbol
4.17 Drain holes
4.18 Resistance to corrosion
4.19 Ignitors
4.20 Rough service luminaires-Vibration
requirements
4.21 Protective shield (tungsten halogen
lamps)
4.22 Attachments to lamps
4.23 Semi-luminaires
4.24 UV radiation
4.25 Mechanical hazard
4.26 Short circuit protection
Section 5: External and internal wiring
5.1 General
5.2 Supply connection and other external wiring
5.3 Internal wiring
Section 6: Not used
Section 7: Provision for earthing
7.1 General
7.2 Provision for earthing
Section 8: Protection against electric shock
8.1 General
8.2 Protection against electric shock
Section 9: Resistance to dust, solid objects
and moisture
9.1 General
9.2 Tests for ingress of dust, solid objects
and moisture
9.3 Humidity test
Section 10: Insulation resistance and electric
strength
10.1 General
10.2 Insulation resistance and electric strength
10.3 Leakage current
Section 11: Creepage distances and clearances
11.1 General
11.2 Creepage distances and clearances
Section 12: Endurance test and thermal test
12.1 General
12.2 Selection of lamps and ballasts
12.3 Endurance test
12.4 Thermal test (normal operation)
12.5 Thermal test (abnormal operation)
12.6 Thermal test (failed lamp controlgear
conditions)
12.7 Thermal test in regard to fault conditions
in lamp control gear or electronic devices
in plastic luminaires
Section 13: Resistance to heat, fire and tracking
13.1 General
13.2 Resistance to heat
13.3 Resistance to flame and ignition
13.4 Resistance to tracking
Section 14: Screw terminals
14.1 General
14.2 Definitions
14.3 General requirements and basic principles
14.4 Mechanical tests
Section 15: Screwless terminals and electrical
connections
15.1 General
15.2 Definitions
15.3 General requirements
15.4 General instructions on tests
15.5 Mechanical tests
15.6 Electrical tests
15.7 Conductors
15.8 Mechanical tests
15.9 Electrical tests
Figures
Annexes
A Test to establish whether a conductive part may
cause an electric shock
B Test lamps
C Abnormal circuit conditions
D Drought-proof enclosure
E Determination of winding temperature rises by
the increase-in-resistance method
F Test for resistance to stress corrosion of
copper and copper alloys
G (deleted)
H (deleted)
J Explanation of IP numbers for degrees of
protection
K Temperature measurement
L Guide to good practice in liminate design
M Conversion guide for table IX of IEC 598-1
(2nd edition) to table 11.1-Determination of
creepage distances and clearances
N Explanation to luminate marking
P Requirements for the protective shield to be
fitted to luminaires using metal halide lamps
for protective measures against UV radiation
Q Conformity testing during manufacture
R Bibliography
S Schedule of amended clauses containing more
serious/critical requirements which require
products to be rested
T Requirements for the identification of a
a family or range of luminaires for type
testing
Covers general requirements for the classification and marking of luminaires and for their mechanical and electrical construction, together with related tests. Applicable to luminaires for use with tungsten filaments, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1000V. Includes the following sections: classification of luminaires; external and internal wiring; protection against electric shock; insulation resistance and electric strength. Also includes definitions, diagrams and annexes.
DocumentType |
Standard
|
Pages |
384
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
Standards | Relationship |
IEC 60598-1:2014+AMD1:2017 CSV | Similar to |
CSA Z305.8 : 2003 | MEDICAL SUPPLY UNITS |
CAN/CSA-Z305.8-03 (R2018) | Medical Supply Units |
CSA Z305.8 : 2003 : R2013 | MEDICAL SUPPLY UNITS |
CSA Z305.8 : 2003 : UPD 1 | MEDICAL SUPPLY UNITS |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60811-3-1:1985 | Common test methods for insulating and sheathing materials ofelectric cables - Part 3: Methods specific to PVC compounds -Section One: Pressure test at high temperature - Tests forresistance to cracking |
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV | Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 61547:2009 | Equipment for general lighting purposes - EMC immunity requirements |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60695-2-1:1991 | Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance |
IEC 60416:1988 | General principles for the formulation of graphical symbols |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60682:1980 | Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps |
IEC 60634:1993 | Heat test source (H.T.S.) lamps for carrying out heating tests on luminaires |
CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
IEC 60570:2003+AMD1:2017 CSV | Electrical supply track systems for luminaires |
IEC 60400:2017 | Lampholders for tubular fluorescent lamps and starterholders |
ISO 75-2:2013 | Plastics — Determination of temperature of deflection under load — Part 2: Plastics and ebonite |
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV | Single-capped fluorescent lamps - Safety specifications |
IEC 61167:2015 | Metal halide lamps - Performance specification |
IEC 60925:1989+AMD1:1996+AMD2:2001 CSV | DC supplied electronic ballasts for tubular fluorescent lamps - Performance requirements |
IEC 60364-7-702:2010 | Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Swimming pools and fountains |
IEC 60921:2004+AMD1:2006 CSV | Ballasts for tubular fluorescent lamps - Performance requirements |
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV | Single-capped fluorescent lamps - Performance specifications |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60364-3:1993 | Electrical installations of buildings - Part 3: Assessment of general characteristics |
IEC 60989:1991 | Separating transformers, autotransformers, variable transformersand reactors. |
ISO 4046:1978 | Paper, board, pulp and related terms — Vocabulary |
IEC 61046:1993 | D.C. or a.c. supplied electronic step-down convertors for filament lamps - General and safety requirements |
IEC 60432-2:1999+AMD1:2005+AMD2:2012 CSV | Incandescent lamps - Safety specifications - Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60923:2005+AMD1:2006 CSV | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60598-2-4:2017 | Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires |
IEC 61184:2017 | Bayonet lampholders |
IEC 60922:1997 | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - General and safety requirements |
IEC 60920:1990 | Ballasts for tubular fluorescent lamps - General and safety requirements |
IEC 60360:1998 | Standard method of measurement of lamp cap temperature rise |
IEC 60630:2005 CSV | Maximum lamp outlines for incandescent lamps |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
ISO 1891:2009 | Fasteners — Terminology |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.