CSA C22.2 NO. 178.3:17
Current
The latest, up-to-date edition.
Transfer switch equipment, over 1000 volts (Binational standard with UL 1008A)
Hardcopy , PDF
English
01-01-2017
PREFACE
INTRODUCTION
1 Scope
2 General Requirements
3 Units of Measurement
4 Reference Publications
5 Definitions
CONSTRUCTION
6 General
7 Enclosure
8 Insulating Material
9 Mounting of Parts
10 Guarding and Accessibility of Live Parts
11 Current-Carrying Parts
12 Field Wiring Terminals for Control Circuits
13 Internal Wiring
14 Isolation
15 Grounding and Bonding
16 Operating Mechanism
17 Overcurrent and Ground-Fault Protection
18 Receptacles
19 Spacings
20 Wiring Space
21 Interlocking
22 Transfer Switches for Service Equipment Use - Requirements
for All Countries
23 Service Equipment for Use in the United States
24 Service Equipment for Use in Canada
25 Transfer Switches Comprised of Circuit Breakers in Switchgear
26 Transfer Switches Comprised of Contactors
27 Transfer Switches Comprised of Load Interrupter Switches in
Metal Enclosed Switchgear
PERFORMANCE
28 General
29 Transfer Switches Comprised of Circuit Breakers in Switchgear
30 Transfer Switches Comprised of Contactors
31 Transfer Switches Comprised of Load Interrupting Switches
in Metal Enclosed Switchgear
32 Other Transfer Switches
33 Operations Tests
34 Overvoltage Test
35 Undervoltage Test
36 Range of Operating Voltages
37 Overload Test
38 Electrical Endurance Test
39 Temperature Test
40 Mechanical Endurance Tests
41 Dielectric Voltage-Withstand Test
42 Partial Discharge Testing Procedures
43 Dielectric Voltage-Withstand Test (Repeated)
44 Withstand Test
45 Closing Test
46 Short-Time Current Rating Test
47 Momentary Withstand Current Test
48 Dielectric Voltage-Withstand Test (Reduced Level)
49 Switching Capacity Test - Isolating Means
50 Isolating Means Interlock Integrity Test
51 Transfer Switch Operator Interlock Integrity Test
52 Impulse Voltage Withstand Tests
53 Enclosure Ground Integrity Test
RATINGS
54 Ratings
MANUFACTURING AND PRODUCTION TESTS
55 Power-Frequency Voltage Withstand Test
MARKINGS
56 Markings
57 Service Equipment Markings
58 Permanence of Marking
59 Installation Test Procedures
60 Transfer Switches for Fire Pump Service
Annex A (informative) - Standards for Components
Annex B (normative) - References
ANNEX C (normative) - Bypass Transfer Switches
ANNEX D (informative) - French Translations of Markings
These requirements cover automatic, non-automatic, and manual transfer switches, operating at voltages of greater than 1000 Vac, and intended for use in non-hazardous locations in accordance with Annex B, Item 1, the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, Part 1, to provide for power as follows: a) Automatic transfer switches for use in emergency systems in: 1) Emergency systems in accordance with the Standard for Emergency Electrical Power Supply for Buildings, CSA C282-15; 2) Health care facilities in accordance with Rule 24-304 of the Canadian Electrical Code (CEC) Part I; 3) Articles 517, Health Care Facilities, and 700, Emergency Systems, of the National Electrical Code, ANSI/NFPA 70 (refer to Annex B, Item 1); and 4) The Health Care Facilities Code, ANSI/NFPA 99, (refer to Annex B, Item 12).
DevelopmentNote |
Also numbered as UL 1008A. (09/2017)
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0044-8
|
Pages |
117
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Preface This is the harmonized CSA Group, and UL standard for Transfer Switch Equipment – Over 1000 Volts . It is the First edition of CSA C22.2 No. 178.3, and the Second edition of UL 1008A. This edition of UL 1008A supersedes the First edition titled, Medium-Voltage Transfer Switches, published on March 30, 2012. This harmonized standard has been jointly revised on April 30, 2020. For this purpose, CSA Group and UL are issuing revision pages dated April 30, 2020. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 These requirements cover automatic, non-automatic, and manual transfer switches, operating at voltages of greater than 1000 Vac, and intended for use in non-hazardous locations in accordance with Annex B, Item 1, the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, Part 1, to provide for power as follows: a) Automatic transfer switches for use in emergency systems in: 1) Emergency systems in accordance with the Standard for Emergency Electrical Power Supply for Buildings, CSA C282-15; 2) Health care facilities in accordance with Rule 24-304 of the Canadian Electrical Code (CEC) Part I; 3) Articles 517, Health Care Facilities, and 700, Emergency Systems, of the National Electrical Code, ANSI/NFPA 70 (refer to Annex B, Item 1); and 4) The Health Care Facilities Code, ANSI/NFPA 99, (refer to Annex B, Item 12). Note: Transfer switches for optional standby systems are not recognized in Canada. b) Transfer switches for use in optional standby systems in accordance with Article 702 of the National Electrical Code, ANSI/NFPA 70 (refer to Annex B, Item 1). Note: Automatic transfer switches for optional standby systems are not recognized in Canada. c) In legally required standby systems in accordance with Article 701 of the National Electrical Code, ANSI/NFPA 70(refer to Annex B, Item 1). Note: Legally-required standby systems are not recognized in Canada. d) Automatic transfer switches for use in accordance with the Standard for the Installation of Stationary Pumps for Fire Protection, ANSI/NFPA 20 or the Standard for Fire Pump Controllers, CSA C22.2 No. 263, (refer to Annex B, Item 2). 1.2 These requirements cover transfer switches rated greater than 1000 V to 46 kV. 1.3 These requirements cover transfer switches together with their associated control devices including, but not limited to, voltage sensing relays, frequency sensing relays, and time delay relays. 1.4 An automatic transfer switch as covered by these requirements is a device that automatically transfers a common load from a normal supply to an alternate supply in the event of failure of the normal supply, and automatically returns the load to the normal supply when the normal supply is restored. An automatic transfer switch can be provided with a logic control circuit that inhibits automatic operation of the device from either a normal to an alternate supply, or from an alternate to a normal supply when the switch reverts to automatic operation upon loss of power to the load. 1.5 A non-automatic transfer switch as covered by these requirements is a device, operated manually by a physical action, or electrically by a remote control, for transferring a common load between a normal and alternate supply. 1.6 These requirements only cover completely enclosed transfer switches.
CSA C22 NO. 4 : 2016 | ENCLOSED AND DEAD-FRONT SWITCHES |
ANSI C37.57 : 1990 | SWITCHGEAR - METAL-ENCLOSED INTERRUPTER SWITCHGEAR ASSEMBLIES - CONFORMANCE TESTING |
IEEE C37.013-1997 | IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis |
UL 514A:11ED 2013-02-01 | Metallic Outlet Boxes |
CSA C22.2 No. 5 : 2013 | MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE SWITCHES AND CIRCUIT-BREAKER ENCLOSURES |
UL 5085-3:1ED 2006-04-17 | Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers |
CSA C22.2 No. 29 : 2015 | PANELBOARDS AND ENCLOSED PANELBOARDS |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
CSA C22.2 No. 0.4 : 2004(R2013) | BONDING OF ELECTRICAL EQUIPMENT |
UL 248-8:3ED 2011-05-13 | Low-Voltage Fuses - Part 8: Class J Fuses |
UL 4248-11:1ED 2007-02-28 | Fuseholders - Part 11: Type C (Edison Base) and Type S Plug Fuse |
IEEE C37.20.2-2015 | IEEE Standard for Metal-Clad Switchgear |
ANSI C37.58 : 1990 | INDOOR AC MEDIUM-VOLTAGE SWITCHES FOR USE IN METAL-ENCLOSED SWITCHGEAR - CONFORMANCE TEST PROCEDURES |
CSA C22.2 No. 144 : 1991 | GROUND FAULT CIRCUIT INTERRUPTERS |
CSA C22.2 No. 0.2 : 2016 | INSULATION COORDINATION |
CSA C22.2 No. 31 : 2014 | SWITCHGEAR ASSEMBLIES |
UL 943:5ED 2016-05-17 | Ground-Fault Circuit-Interrupters |
UL 4248-9:1ED 2007-02-28 | Fuseholders - Part 9: Class K |
UL 514C:4ED 2014-04-08 | Nonmetallic Outlet Boxes, Flush-Device Boxes, and Covers |
ANSI C37.55 : 1989 | MEDIUM VOLTAGE METAL-CLAD ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
CSA C22.2 No. 65 : 2013 | WIRE CONNECTORS |
UL 248-12:3ED 2011-05-13 | Low-Voltage Fuses - Part 12: Class R Fuses |
IEEE C37.20.3-2013 REDLINE | IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV) |
IEEE C37.20.4-2013 | IEEE Standard for Indoor AC Switches (1 kV to 38 kV) for Use in Metal-Enclosed Switchgear |
UL 248-4:2ED 2000-08-01 | Low-Voltage Fuses - Part 4: Class CC Fuses |
IEEE C37.40-2003 | IEEE Standard Service Conditions and Definitions for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories |
ANSI C37.54 : 1996 | FOR INDOOR ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS APPLIED AS REMOVABLE ELEMENTS IN METAL-ENCLOSED SWITCHGEAR ASSEMBLIES - CONFORMANCE TEST PROCEDURES |
CSA C22.2 No. 0.15 : 2015 | ADHESIVE LABELS |
NFPA 99 : 2018 | HEALTH CARE FACILITIES CODE |
CSA C22.2 No. 263 : 2015 | FIRE PUMP CONTROLLERS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
UL 248-10:3ED 2011-05-13 | Low-Voltage Fuses - Part 10: Class L Fuses |
IEEE C37.09-1999 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis |
CSA C22.2 No. 210 : 2015 | APPLIANCE WIRING MATERIAL PRODUCTS |
C22.2 NO. 4248.1-17 | Fuseholders Part 1: General requirements (Trinational standard with UL 4248-1 and NMX-J-009/4248/1-ANCE) |
NEMA CC1 : 2009(R2015) | ELECTRIC POWER CONNECTORS FOR SUBSTATIONS |
UL 4248-15:1ED 2007-02-28 | Fuseholders - Part 15: Class T |
UL 4248-4:1ED 2007-02 | Fuseholders - Part 4: Class CC |
CSA C22.2 No. 14 : 2013 | INDUSTRIAL CONTROL EQUIPMENT |
CSA C22.2 No. 253 : 2016 | MEDIUM-VOLTAGE AC CONTACTORS, CONTROLLERS, AND CONTROL CENTRES |
CSA C22.2 No. 144.1 : 2016 | GROUND-FAULT CIRCUIT-INTERRUPTERS |
NFPA 20 : 2016 | INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION |
UL 248-5:2ED 2000-08-01 | Low-Voltage Fuses - Part 5: Class G Fuses |
CSA C22.2 No. 94.2 : 2015 | ENCLOSURES FOR ELECTRICAL EQUIPMENT, ENVIRONMENTAL CONSIDERATIONS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.