CSA/ANSI Z21.60-2017/CSA 2.26-2017
Current
The latest, up-to-date edition.
Decorative gas appliances for installation in solid-fuel burning fireplaces
English
01-01-2017
Preface
1 Scope
2 Reference publications
3 Definitions
4 Construction
5 Performance
6 Manufacturing and production tests
7 Items unique to the United States
8 Items unique to Canada
Annex A (normative) - Outline of lighting instructions for
appliances equipped with continuous pilots
Annex B (normative) - Outline of operating instructions for
appliances equipped with intermittent pilot or
interrupted pilot systems
Annex C (normative) - Outline of operating instructions for
appliances equipped with direct ignition systems
Annex D (normative) - Provisions for listed gas appliance
conversion kits (optional)
Annex E (informative) - Pertinent references to ANSI Y14.15
Annex F (informative) - Wire color designations
Annex G (informative) - Recommended wire color usage
Annex H (informative) - Preferred graphic symbols of
commonly used items, extracted from the
Standard for Graphic Symbols for Electrical
and Electronics Diagrams, ANSI/ IEEE 315,
and abbreviations for these items
Annex I (informative) - Table of conversion factors
Pertains to decorative gas appliances for installation in solid-fuel burning fireplaces, hereinafter referred to as appliances, which are constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117228 W).
DevelopmentNote |
Also numbered as CSA 2.26. (10/2001) Effective in Canada August 1, 2018. (02/2017)
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0685-3
|
Pages |
118
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the fourth edition of ANSI Z21.60/CSA 2.26, Decorative gas appliances for installation in solid- fuel burning fireplaces. It supersedes the previous editions published in 2012, 2003, and 1996. Scope 1.1 This Standard applies to decorative gas appliances for installation in solid-fuel burning fireplaces, (see Clause 3, Definitions), hereinafter referred to as appliances, which are constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W). These appliances are: a) for use with natural gas; b) for use with propane gas; c) for use with natural and convertible for use with propane gas (see Clause 3, Definitions); d) for manufactured home (U.S. only) or mobile home installation for use with natural and convertible for use with propane gas; and e) for manufactured home (U.S. only) or mobile home installation for use with propane gas only. The construction of decorative appliances for installation in solid-fuel burning fireplaces for use with the above-mentioned gases is covered under Clause 4. The performance of decorative appliances for installation in solid-fuel burning fireplaces for use with the above-mentioned gases is covered under Clause 5. 1.2 Decorative appliances for installation in solid-fuel burning fireplaces are not thermostatically controlled. 1.3 This Standard does not cover unvented room heaters. 1.4 The use of the term \"appliance\" henceforth in this Standard is in reference to a decorative gas appliance for installation in a solid-fuel burning fireplace. 1.5 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. (Also see Clause 8.3.) 1.6 All references to psi throughout this Standard are to be considered gage pressure unless otherwise specified. 1.7 Clause 7, Items unique to the United States, contains provisions that are unique to the United States. 1.8 Clause 8, Items unique to Canada, contains provisions that are unique to Canada. 1.9 Special construction provisions applicable to an appliance designed for use with an optional listed conversion kit are outlined under Annex D, Provisions for listed gas appliances conversion kits (optional). 1.10 Clause 2 contains a list of standards specifically referenced in this Standard and sources from which they may be obtained. Clause 2 includes both U.S. and Canadian reference standards where applicable. It is the responsibility of the user of this Standard to determine which referenced standard applies based on the requirements of the authority having jurisdiction at the location of the installation.
CSA C22.2 No. 49 : 2014 | FLEXIBLE CORDS AND CABLES |
CSA Z234.1 : 0 | METRIC PRACTICE GUIDE |
CSA 6.5 : 2015 | AUTOMATIC VALVES FOR GAS APPLIANCES |
CSA B78.4 : 1979 | ELECTRIC AND ELECTRONICS DIAGRAMS |
NFPA 501A : 2017 | FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES, AND COMMUNITIES |
IEEE/ASTM SI_10-2010 | American National Standard for Metric Practice |
ASME PTC19.3 : 1974(R2004) | PERFORMANCE TEST CODE - PART 3: TEMPERATURE MEASUREMENT |
IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
ASME B1.20.1 : 2013(R2018) | PIPE THREADS, GENERAL PURPOSE (INCH) |
CSA 6.10 : 2015 | CONNECTORS FOR GAS APPLIANCES |
NEMA WD 6 : 2016 | WIRING DEVICES - DIMENSIONAL SPECIFICATIONS |
ASME B36.10M : 2015 | WELDED AND SEAMLESS WROUGHT STEEL PIPE |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
UL 372:6ED 2007-07-31 | Automatic Electrical Controls for Household and Similar Use - Part 2: Particular Requirements for Burner Ignition Systems and Components |
CSA Z240 MH SERIES : 2016 | MANUFACTURED HOMES |
ANSI C101.1 : 1992 | LEAKAGE CURRENT FOR APPLIANCES |
NCSBCS A225.1 : 1994 | MANUFACTURED HOME INSTALLATIONS |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
ANSI Z223.1 : 2018 | NATIONAL FUEL GAS CODE |
ANSI Z21.24 : 2015 | CONNECTORS FOR GAS APPLIANCES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.