CLC/TS 60034-25:2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Rotating electrical machines - Part 25: Guidance for the design and performance of a.c. motors specifically designed for converter supply
02-02-2024
12-12-2008
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 System characteristics
4.1 General
4.2 System information
4.3 Torque/speed considerations
4.4 Motor requirements
5 Losses and their effects (for induction motors fed from
U-converters)
5.1 General
5.2 Location of the additional losses due to converter
supply and ways to reduce them
5.3 Converter features to reduce the motor losses
5.4 Use of filters to reduce additional motor losses
due to converter supply
5.5 Temperature and life expectancy
5.6 Determination of motor efficiency
6 Noise, vibration and torsional oscillation
6.1 Noise
6.2 Vibration (excluding torsional oscillation)
6.3 Torsional oscillation
7 Motor insulation electrical stresses
7.1 General
7.2 Causes
7.3 Winding electrical stress
7.4 Insulation stress limitation
7.5 Responsibilities
7.6 Converter characteristics
7.7 Methods of reduction of voltage stress
7.8 Motor choice
8 Bearing currents
8.1 Sources of bearing currents in converter-fed
motors
8.2 Generation of high-frequency bearing currents
8.3 Common mode circuit
8.4 Stray capacitances
8.5 Consequences of excessive bearing currents
8.6 Preventing high-frequency bearing current damage
8.7 Additional considerations for motors fed by high
voltage U-converters
8.8 Bearing current protection for motors fed by
high-voltage current-source converters (I-converters)
9 Installation
9.1 Earthing, bonding and cabling
9.2 Reactors and filters
9.3 Integral motors (integrated motor and drive modules)
10 Additional considerations for permanent magnet (PM)
synchronous motors fed by U-converters
10.1 System characteristics
10.2 Losses and their effects
10.3 Noise, vibration and torsional oscillation
10.4 Motor insulation electrical stresses
10.5 Bearing currents
10.6 Particular aspects of permanent magnets
11 Additional considerations for cage induction motors
fed by high voltage U-converters
11.1 General
11.2 System characteristics
11.3 Losses and their effects
11.4 Noise, vibration and torsional oscillation
11.5 Motor insulation electrical stresses
11.6 Bearing currents
12 Additional considerations for synchronous motors
fed U-converters
12.1 System characteristics
12.2 Losses and their effects
12.3 Noise, vibration and torsional oscillation
12.4 Motor insulation electrical stresses
12.5 Bearing currents
13 Additional considerations for cage induction motors
fed by block-type I-converters
13.1 System characteristics
13.2 Losses and their effects
13.3 Noise, vibration and torsional oscillation
13.4 Motor insulation electrical stresses
13.5 Bearing currents
13.6 Additional considerations for six-phase cage
induction motors
14 Additional considerations for synchronous motors
fed by LCI
14.1 System characteristics
14.2 Losses and their effects
14.3 Noise, vibration and torsional oscillation
14.4 Motor insulation electrical stresses
14.5 Bearing currents
15 Additional considerations for pulsed I-converters (PWM CSI)
feeding induction motors
15.1 System characteristics
15.2 Losses and their effects
15.3 Noise, vibration and torsional oscillation
15.4 Motor insulation electrical stresses
15.5 Bearing currents
16 Other motor/converter systems
16.1 Drives supplied by cyclo-converters
16.2 Wound rotor induction (asynchronous) machines
supplied by I-converters in the rotor circuit
16.3 Wound rotor induction (asynchronous) machines
supplied by U-converters in the rotor circuit
Annex A (normative) - Converter characteristics
Annex B (informative) - Converter output spectra
Annex C (informative) - Noise increments due to converter
supply
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Describes the design features and performance characteristics of polyphase cage induction motors specifically designed for use on voltage source converter supplies up to 1 000 V. Also specifies the interface parameters and interactions between the motor and the converter including installation guidance as part of a power drive system.
Committee |
CLC/TC 2
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
DIN CLC/TS 60034-25 : 2006 | Identical |
VDE V 0530-25 : 2006 | Identical |
NEN NPR IEC CLC/TS 60034-25 : 2008 | Identical |
CEI CLC/TS 60034-25 : 2010 | Identical |
NEN NPR CLC IEC/TS 60034-25 : 2006 | Identical |
DIN VDE 0530-25 : 2009 | Identical |
VDE 0530-25 : 2009 | Identical |
I.S. CLC TS 60034-25:2005 | Identical |
IEC TS 60034-25:2014 | Identical |
DS CLC/TS 60034-25 : 2009 | Identical |
S.R. CLC/TS 60034-25:2008 | Identical |
I.S. EN 60034-30-1:2014 | ROTATING ELECTRICAL MACHINES - PART 30-1: EFFICIENCY CLASSES OF LINE OPERATED AC MOTORS (IE CODE) |
I.S. EN 60079-15:2010 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
VDE 0160-109-2 : 2018-01 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 9-2: ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS AND THEIR DRIVEN APPLICATIONS - ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS (IEC 61800-9-2:2017) |
EN 60034-18-41:2014 | Rotating electrical machines - Part 18-41: Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters - Qualification and quality control tests |
EN 60034-30-1:2014 | Rotating electrical machines - Part 30-1: Efficiency classes of line operated AC motors (IE code) |
CEI EN 60034-28 : 2014 | ROTATING ELECTRICAL MACHINES - PART 28: TEST METHODS FOR DETERMINING QUANTITIES OF EQUIVALENT CIRCUIT DIAGRAMS FOR THREE-PHASE LOW-VOLTAGE CAGE INDUCTION MOTORS |
CEI EN 60079-15 : 2012 | EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N' |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
BS EN 60034-28:2013 | Rotating electrical machines Test methods for determining quantities of equivalent circuit diagrams for three-phase low-voltage cage induction motors |
09/30214359 DC : 0 | BS EN 50533 - RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
I.S. EN 60034-18-41:2014 | ROTATING ELECTRICAL MACHINES - PART 18-41: PARTIAL DISCHARGE FREE ELECTRICAL INSULATION SYSTEMS (TYPE 1) USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS - QUALIFICATION AND QUALITY CONTROL TESTS |
BS EN 60034-30-1:2014 | Rotating electrical machines Efficiency classes of line operated AC motors (IE code) |
BS EN 60079-15:2010 | Explosive atmospheres Equipment protection by type of protection \'n\' |
UNE-EN 60079-14:2016 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
DIN EN 61800-9-2 : 2018-01 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 9-2: ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS AND THEIR DRIVEN APPLICATIONS - ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS (IEC 61800-9-2:2017) |
BS EN 60034-30:2009 | Rotating electrical machines Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code) |
CEI EN 60034-30-1 : 2015 | ROTATING ELECTRICAL MACHINES - PART 30-1: EFFICIENCY CLASSES OF LINE OPERATED AC MOTORS (IE CODE) |
CEI EN 60034-18-41 : 2014 | ROTATING ELECTRICAL MACHINES - PART 18-41: PARTIAL DISCHARGE FREE ELECTRICAL INSULATION SYSTEMS (TYPE I) USED IN ROTATING ELECTRICAL MACHINES FED FROM VOLTAGE CONVERTERS - QUALIFICATION AND QUALITY CONTROL TESTS |
CEI CLC/TS 50534 : 2011 | RAILWAY APPLICATIONS - GENERIC SYSTEM ARCHITECTURES FOR ONBOARD ELECTRIC AUXILIARY POWER SYSTEMS |
BS EN 60079-0 : 2012 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS |
I.S. EN 60034-28:2013 | ROTATING ELECTRICAL MACHINES - PART 28: TEST METHODS FOR DETERMINING QUANTITIES OF EQUIVALENT CIRCUIT DIAGRAMS FOR THREE-PHASE LOW-VOLTAGE CAGE INDUCTION MOTORS (IEC 60034-28:2012 (EQV)) |
UNE-EN 50533:2012 | Railway applications - Three-phase train line voltage characteristics. |
UNE-EN 60079-15:2013 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
BS EN 50598-2 : 2014 | ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS |
BS EN 60034-18-41:2014 | Rotating electrical machines Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters. Qualification and quality control tests |
PREN 50533 : DRAFT 2009 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
UNE-EN 60034-28:2013 | Rotating electrical machines - Part 28: Test methods for determining quantities of equivalent circuit diagrams for three-phase low-voltage cage induction motors |
UNE-EN 50598-2:2015 | Ecodesign for power drive systems, motor starters, power electronics & their driven applications - Part 2: Energy efficiency indicators for power drive systems and motor starters |
I.S. EN 50598-2:2014 | ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 60034-28:2013 | Rotating electrical machines - Part 28: Test methods for determining quantities of equivalent circuit diagrams for three-phase low-voltage cage induction motors |
EN 50598-2:2014/A1:2016 | ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS |
IEC 61800-3:2017 | Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods |
IEC 61800-2:2015 | Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifications for low voltage adjustable speed a.c. power drive systems |
IEC 61800-4:2002 | Adjustable speed electrical power drive systems - Part 4: General requirements - Rating specifications for a.c. power drive systems above 1 000 V a.c. and not exceeding 35 kV |
EN 61800-5-2:2017 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
IEC 60034-9:2003+AMD1:2007 CSV | Rotating electrical machines - Part 9: Noise limits |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
IEC TR 61000-5-2:1997 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling |
EN 60034-14:2004/A1:2007 | ROTATING ELECTRICAL MACHINES - PART 14: MECHANICAL VIBRATION OF CERTAIN MACHINES WITH SHAFT HEIGHTS 56 MM AND HIGHER - MEASUREMENT, EVALUATION AND LIMITS OF VIBRATION SEVERITY |
IEC TS 60034-18-41:2006 | Rotating electrical machines - Part 18-41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters |
EN 60034-9:2005/A1:2007 | ROTATING ELECTRICAL MACHINES - PART 9: NOISE LIMITS |
EN 61800-5-1:2007/A1:2017 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-1: SAFETY REQUIREMENTS - ELECTRICAL, THERMAL AND ENERGY (IEC 61800-5-1:2007/A1:2016) |
EN 61800-2:2015 | Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifications for low voltage adjustable speed a.c. power drive systems |
IEC TS 60034-17:2006 | Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide |
IEC 60034-14:2003+AMD1:2007 CSV | Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights 56 mm and higher - Measurement, evaluation and limits of vibration severity |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
IEC 60034-2:1972 | Rotating electrical machines. Part 2: Methods for determining losses and efficiency of rotating electrical machinery from tests (excluding machines for traction vehicles) |
EN 61800-3 : 2004 AMD 1 2012 | ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 3: EMC REQUIREMENTS AND SPECIFIC TEST METHODS (IEC 61800-3:2004/A1:2011) |
EN 60034-2:1996/A2:1996 | ROTATING ELECTRICAL MACHINES - PART 2: METHODS FOR DETERMINING LOSSES AND EFFICIENCY OF ROTATING ELECTRICAL MACHINERY FROM TESTS (EXCLUDING MACHINES FOR TRACTION VEHICLES) |
IEC TR 61800-6:2003 | Adjustable speed electrical power drive systems - Part 6: Guide for determination of types of load duty and corresponding current ratings |
EN 60034-6:1993 | Rotating electrical machines - Part 6: Methods of cooling (IC Code) |
IEC 61800-5-2:2016 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
IEC TR 61000-5-1:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.