CLC/TS 50537-2:2010
Current
The latest, up-to-date edition.
Railway applications - Mounted parts of the traction transformer and cooling system - Part 2: Pump for insulating liquid for traction transformers and reactors
12-02-2010
1 Scope
2 Normative references
3 Terms and definitions
4 Operating conditions
5 Electrical requirements
6 Mechanical requirements
7 Hydraulic requirements
8 Fire protection
9 Reliability and lifetime
10 Material
11 Noise
12 Markings
13 Documentation
14 Testing
Bibliography
This Technical Specification covers requirements for electric pumps which generate the circulation of insulation liquid in traction transformers and reactors of rail vehicles and their associated cooling system.The pumps covered by this Technical Specification are rotodynamic pumps driven by a squirrel cage induction motor which is immersed in the insulating liquid. CLC/TS 50537-2 gives consideration to both technical and normative requirements of the railway environment and restricts the variety provided by industry-wide standards for pumps (for example EN 50216-7 and EN ISO 9906). It determines requirements and tests enabling the interchangeability especially regarding electrical, mechanical and hydraulic interfaces. Furthermore, service conditions are described.
Committee |
CLC/TC 9X
|
DevelopmentNote |
To be read in conjunction with CLC/TS 50534. (03/2010)
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
CEI CLC/TS 50537-2 : 2011 | Identical |
VDE V 0115-537-2 : 2011-04 | Identical |
NEN NPR CLC/TS 50537-2 : 2010 | Identical |
DD CLC/TS 50537-2:2010 | Identical |
DIN CLC/TS 50537-2 : 2011-04 | Identical |
S.R. CLC/TS 50537-2:2010 | Identical |
PREN 50547 : DRAFT 2011 | RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
DD CLC/TS 50537-3:2010 | Railway applications. Mounted parts of the traction transformer and cooling system Water pump for traction converters |
UNE-EN 50547:2013 | Railway applications - Batteries for auxiliary power supply systems |
I.S. EN 50547:2013 | RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
CEI CLC/TS 50537-4 : 2011 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 4: GAS AND LIQUID ACTUATED (BUCHHOLZ) RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR FOR RAIL VEHICLES |
CLC/TS 50537-3:2010 | Railway applications - Mounted parts of the traction transformer and cooling system - Part 3: Water pump for traction converters |
CEI CLC/TS 50537-3 : 2011 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 3: WATER PUMP FOR TRACTION CONVERTERS |
11/30235301 DC : 0 | BS EN 50547 - RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
DD CLC/TS 50537-1:2010 | Railway applications. Mounted parts of the traction transformer and cooling system HV bushing for traction transformers |
CEI CLC/TS 50537-1 : 2011 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 1: HV BUSHING FOR TRACTION TRANSFORMERS |
CLC/TS 50537-4:2010 | Railway applications - Mounted parts of the traction transformer and cooling system - Part 4: Gas and liquid actuated (Buchholz) relay for liquid immersed transformers and reactors with conservator for rail vehicles |
CLC/TS 50537-1:2010 | Railway applications - Mounted parts of the traction transformer and cooling system - Part 1: HV bushing for traction transformers |
DD CLC/TS 50537-4:2010 | Railway applications. Mounted parts of the traction transformer and cooling system Gas and liquid actuated (Buchholz) relay for liquid immersed transformers and reactors with conservator for rail vehicles |
BS EN 50547:2013 | Railway applications. Batteries for auxiliary power supply systems |
CEI EN 50547 : 2014 | RAILWAY APPLICATIONS - BATTERIES FOR AUXILIARY POWER SUPPLY SYSTEMS |
S.R. CLC/TS 50537-1:2010 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 1: HV BUSHING FOR TRACTION TRANSFORMERS |
S.R. CLC/TS 50537-4:2010 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 4: GAS AND LIQUID ACTUATED (BUCHHOLZ) RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR FOR RAIL VEHICLES |
S.R. CLC/TS 50537-3:2010 | RAILWAY APPLICATIONS - MOUNTED PARTS OF THE TRACTION TRANSFORMER AND COOLING SYSTEM - PART 3: WATER PUMP FOR TRACTION CONVERTERS |
EN 50547:2013 | Railway applications - Batteries for auxiliary power supply systems |
ISO 9906:2012 | Rotodynamic pumps — Hydraulic performance acceptance tests — Grades 1, 2 and 3 |
PREN 50533 : DRAFT 2009 | RAILWAY APPLICATIONS - THREE-PHASE TRAIN LINE VOLTAGE CHARACTERISTICS |
CLC/TS 50534:2010 | Railway applications - Generic system architectures for onboard electric auxiliary power systems |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
IEC 60034-9:2003+AMD1:2007 CSV | Rotating electrical machines - Part 9: Noise limits |
CLC/TS 50467 : 2008 COR 2008 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
CLC/TS 50537-3:2010 | Railway applications - Mounted parts of the traction transformer and cooling system - Part 3: Water pump for traction converters |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
EN 50121-3-2:2016 | Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
EN 50121-1:2017 | Railway applications - Electromagnetic compatibility - Part 1: General |
EN 50547:2013 | Railway applications - Batteries for auxiliary power supply systems |
EN 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicle installations |
IEC 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classificationof groups of environmental parameters and their severities -Section 5: Ground vehicle installations |
EN 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
IEC 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
ISO 281:2007 | Rolling bearings Dynamic load ratings and rating life |
EN 60034-9:2005/A1:2007 | ROTATING ELECTRICAL MACHINES - PART 9: NOISE LIMITS |
IEC 60349-2:2010 | Electric traction - Rotating electrical machines for rail and road vehicles - Part 2: Electronic converter-fed alternating current motors |
IEC 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
CLC/TS 50535:2010 | Railway applications - Onboard auxiliary power converter systems |
EN 50125-1:2014 | Railway applications - Environmental conditions for equipment - Part 1: Rolling stock and on-board equipment |
EN 1092-4:2002 | Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories, PN designated - Part 4: Aluminium alloy flanges |
EN 60349-2:2010 | ELECTRIC TRACTION - ROTATING ELECTRICAL MACHINES FOR RAIL AND ROAD VEHICLES - PART 2: ELECTRONIC CONVERTER-FED ALTERNATING CURRENT MOTORS |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 1706:2010 | Aluminium and aluminium alloys - Castings - Chemical composition and mechanical properties |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
EN 50216-7:2002 | Power transformer and reactor fittings - Part 7: Electric pumps for transformer oil |
CLC/TS 50537-1:2010 | Railway applications - Mounted parts of the traction transformer and cooling system - Part 1: HV bushing for traction transformers |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
ISO 9001:2015 | Quality management systems — Requirements |
CLC/TS 50537-4:2010 | Railway applications - Mounted parts of the traction transformer and cooling system - Part 4: Gas and liquid actuated (Buchholz) relay for liquid immersed transformers and reactors with conservator for rail vehicles |
EN 1563:2011 | Founding - Spheroidal graphite cast irons |
EN ISO 9906:2012 | Rotodynamic pumps - Hydraulic performance acceptance tests - Grades 1, 2 and 3 (ISO 9906:2012) |
EN 733:1995 | End-suction centrifugal pumps, rating with 10 bar with bearing bracket - Nominal duty point, main dimensions, designation system |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 1092-2:1997 | Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories, PN designated - Part 2: Cast iron flanges |
EN 1561:2011 | Founding - Grey cast irons |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.