Surveillance from first commissioning on measuring devices used in natural gas supply to the installations of the activities under the Directive 2003/87/EC establishing a scheme of CO2 emissions trading
05-12-2012
Foreword
1 Scope
2 Terms and definitions
3 Surveillance
4 Proposal for a European scheme related to
common provisions and limit values
Annex A (informative) - National Situations
regarding Devices Measuring the Supply of
Gas Natural for the Activities Listed in Annex
1 of ETD
Bibliography
This Technical Report establishes minimum provisions for the surveillance, based on available standards from first commissioning, of devices and systems with measuring function throughout their technical life when used in the activities of the categories listed in the Annex I of the European Directive 2003/87/EC. It does so in order to ensure the compliance with the expected maximum allowable difference of indication. This Technical Report applies to devices/systems with the function to measure:-volumetric or mass amount of natural gas consumption (any type of gas meters),-volumetric amount of natural gas consumption at specified base conditions (conversion devices),-composition of natural gas (gas chromatographs),for calculating, in accordance with the applicable provisions of the guidelines C(2007) 3416, the amount of the CO2 emissions from the source stream of natural gas.Users of this document should be aware that more detailed national recommendations/standards and/or codes of practice as well as national measures possibly approved by National Regulator may exist inside the EU Member States. When national regulations have to be applied, this document should not be considered.Except in the aforementioned case, this Technical Report is intended to be applied in association with applicable national recommendations/standards and/or codes of practice setting out the above mentioned surveillance provisions.In the event of conflict in terms of different requirements in national regulations/standards and in the provisions of this document, the national regulations/standards will take precedence.Referring to the aforesaid Commission's guidelines C(2007) 3416, SFG_I opts for the calculation based method to determine the amount of the CO2 emissions.Regarding commercially traded of natural gas, competent authorities may permit the determination of the annual gas consumption leading to evaluation of CO2 emissions based solely on the invoiced amount of gas without further individual proof of associated uncertainties, provided that national legislation or the documented application of standards ensures that respective uncertainty requirements for activity data are met for commercial transactions (guidelines C(2007) 3416 -annex 1 §7).Referring to 5.2 and to Chapter 16, annex 1 of guidelines C(2007) 3416, for installations with “de minimis” souce streams and with low emissions respectively, the provisions of this document can be waived.
Committee |
CEN/BT
|
DocumentType |
Technical Report
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
PD CEN/TR 16478:2012 | Identical |
NEN NPR CEN/TR 16478 : 2012 | Identical |
S.R. CEN/TR 16478:2012 | Identical |
DIN CEN/TR 16478;DIN SPEC 31008:2013-05 | Identical |
UNE-CEN/TR 16478:2013 IN | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN 12405-1:2005+A2:2010 | Gas meters - Conversion devices - Part 1: Volume conversion |
ISO 6976:2016 | Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from composition |
2004/22/EC : 2004 | DIRECTIVE 2004/22/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 31 MARCH 2004 ON MEASURING INSTRUMENTS |
ISO 2975-1:1974 | Measurement of water flow in closed conduits — Tracer methods — Part 1: General |
AGA XQ0311 : 2003 | MEASUREMENT OF NATURAL GAS BY CORIOLIS METER |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
API MPMS CH14.9 : 2ED 2013 | MANUAL OF PETROLEUM MEASUREMENT STANDARDS - MEASUREMENT OF NATURAL GAS BY CORIOLIS METER |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ISO 10790:2015 | Measurement of fluid flow in closed conduits Guidance to the selection, installation and use of Coriolis flowmeters (mass flow, density and volume flow measurements) |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1359:2017 | Gas meters - Diaphragm gas meters |
AGA XQ0701 : 0 | AGA REPORT NO. 9, MEASUREMENT OF GAS BY MULTIPATH ULTRASONIC METERS |
EN ISO 6976:2016 | Natural gas - Calculation of calorific values, density, relative density and Wobbe indices from composition (ISO 6976:2016) |
ISO/TR 12764:1997 | Measurement of fluid flow in closed conduits Flowrate measurement by means of vortex shedding flowmeters inserted in circular cross-section conduits running full |
EN 1776:2015 | Gas infrastructure - Gas measuring systems - Functional requirements |
EN 12186:2014 | Gas infrastructure - Gas pressure regulating stations for transmission and distribution - Functional requirements |