BS TA 48:1973
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Specification for forgings of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1050-1200 N/mm2) (limiting ruling section 100 mm)
Hardcopy , PDF
30-11-2009
English
02-02-1973
NO CONTENTS SECTION
Describes manufacture, inspection and testing of heat resisting alloys for aerospace purposes. Covers forgings, plate, strip, tubes and bars. Gives chemical composition and mechanical properties. Covers forgings of titanium-aluminium-molybdenum-tin-silicon alloy.
Committee |
ACE/61/-/49
|
DevelopmentNote |
Supersedes 71/33667 DC, BS TA31(1969), BS TA34(1969) and BS TA37(1969) (08/2005) Reviewed and confirmed by BSI, January 2008. (12/2007)
|
DocumentType |
Standard
|
Pages |
8
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
BS TA 49:1973 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1000-1200 N/mm<sup>2</sup>) (limiting ruling section over 100 mm up to and including 150 mm) |
BS TA 47:1973 | Specification for forging stock of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1050-1220 N/mm<sup>2</sup>) (limiting ruling section 100 mm) |
BS 2TA 45:2009 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1100-1280 MPa) (limiting ruling section 25 mm) |
BS 2TA 57:2009 | Specification for plate of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1030-1220 MPa) (thickness over 50 mm up to and including 65 mm) |
BS TA 51:1973 | Specification for forgings of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1000-1200 N/mm<sup>2</sup>) (limiting ruling section over 100 mm up to and including 150 mm) |
09/30193535 DC : 0 | BS 2TA 50 - SPECIFICATION FOR FORGING STOCK OF TITANIUM-ALUMINIUM-MOLYBDENUM-TIN-SILICON ALLOY - TENSILE STRENGTH 1000-1200 MPA - LIMITING RULING SECTION OVER 100 MM UP TO AND INCLUDING 150 MM |
BS TA 45:1973 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1100-1280 N/mm<sup>2</sup>) (limiting ruling section 25 mm) |
09/30193179 DC : 0 | BS 2TA 45 - SPECIFICATION FOR BAR AND SECTION OF TITANIUM-ALUMINIUM-MOLYBDENUM-TIN-SILICON-CARBON ALLOY (TENSILE STRENGTH 1100-1280 MPA) (LIMITING RULING SECTION 25 MM) |
BS TA 50:1973 | Specification for forging stock of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1000-1200 N/mm<sup>2</sup>) (limiting ruling section over 100 mm up to and including 150 mm) |
09/30193543 DC : 0 | BS 2TA 57 - SPECIFICATION FOR PLATE OF TITANIUM-ALUMINIUM-MOLYBDENUM-TIN-SILICON ALLOY - TENSILE STRENGTH 1030-1220 MPA - MAXIMUM THICKNESS 65 MM |
09/30193187 DC : 0 | BS 2TA 49 - SPECIFICATION FOR BAR AND SECTION FOR MACHINING OF TITANIUM-ALUMINIUM-MOLYBDENUM-TIN-SILICON-CARBON ALLOY (TENSILE STRENGTH 1000-1200 MPA) (LIMITING RULING SECTION OVER 100 MM UP TO AND INCLUDING 150 MM) |
BS 2TA 46:2009 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1050-1220 MPa) (limiting ruling section over 25 mm up to and including 100 mm) |
BS 2TA 49:2009 | Specification for bar and section for machining of titanium-aluminium- molybdenum-tin-silicon-carbon alloy (Tensile strength 1000-1200 MPa) (Limiting ruling section over 100 mm up to and including 150 mm) |
BS 2TA 51:2009 | Specification for forgings of titanium-aluminium- molybdenum-tin-silicon alloy (tensile strength 1000-1200 MPa) (limiting ruling section over 100 mm up to and including 150 mm) |
BS 2TA 47:2009 | Specification for forging stock of titanium- aluminium-molybdenum-tin-silicon alloy (tensile strength 1050-1220 MPa) (limiting ruling section 100 mm) |
BS TA 46:1973 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1050-1220 N/mm<sup>2</sup>) (limiting ruling section over 25 mm up to and including 100 mm) |
09/30193183 DC : 0 | BS 2TA 47 - SPECIFICATION FOR FORGING STOCK OF TITANIUM-ALUMINIUM-MOLYBDENUM-TIN-SILICON-CARBON ALLOY (TENSILE STRENGTH 1050-1220 MPA) (LIMITING RULING SECTION 100 MM) |
09/30193181 DC : 0 | BS 2TA 46 - SPECIFICATION FOR BAR AND SECTION FOR MACHINING OF TITANIUM-ALUMINIUM-MOLYBDENUM-TIN-SILICON-CARBON ALLOY (TENSILE STRENGTH 1050-1220 MPA) (LIMITING RULING SECTION OVER 25 MM UP TO AND INCLUDING 100 MM) |
09/30193537 DC : 0 | BS 2TA 51 - SPECIFICATION FOR FORGINGS OF TITANIUM-ALUMINIUM-MOLYBDENUM-TIN-SILICON ALLOY - TENSILE STRENGTH 1000-1200 MPA - LIMITING RULING SECTION OVER 100 MM UP TO AND INCLUDING 150 MM |
BS TA 57:1974 | Specification for plate of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1030-1220 MPa) (maximum thickness 65 mm) |
BS 2TA 50:2009 | Specification for forging stock of titanium- aluminium-molybdenum-tin-silicon alloy (tensile strength 1000-1200 MPa) (limiting ruling section over 100 mm up to and including 150 mm) |
BS TA 45:1973 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1100-1280 N/mm<sup>2</sup>) (limiting ruling section 25 mm) |
BS 2TA 100:1973 | Procedure for inspection and testing of wrought titanium and titanium alloys |
BS TA 50:1973 | Specification for forging stock of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1000-1200 N/mm<sup>2</sup>) (limiting ruling section over 100 mm up to and including 150 mm) |
BS TA 51:1973 | Specification for forgings of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1000-1200 N/mm<sup>2</sup>) (limiting ruling section over 100 mm up to and including 150 mm) |
BS TA 46:1973 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1050-1220 N/mm<sup>2</sup>) (limiting ruling section over 25 mm up to and including 100 mm) |
BS TA 49:1973 | Specification for bar and section for machining of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1000-1200 N/mm<sup>2</sup>) (limiting ruling section over 100 mm up to and including 150 mm) |
BS 3763:1970 | The International System of units (SI) |
BS 350:2004 | Conversion factors for units |
BS TA 47:1973 | Specification for forging stock of titanium-aluminium-molybdenum-tin-silicon alloy (tensile strength 1050-1220 N/mm<sup>2</sup>) (limiting ruling section 100 mm) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.