BS ISO 7240-8:2014

Current

Current

The latest, up-to-date edition.

Fire detection and alarm systems Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-01-2015

$618.22
Including GST where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions and abbreviated terms
4 Requirements
5 Tests
6 Test report
7 Marking
8 Data
Annex A (normative) - Gas test chamber for CO
        response value and cross sensitivity measurements
Annex B (normative) - Heat tunnel for response time and
        response temperature measurements
Annex C (normative) - Apparatus for impact test
Annex D (normative) - Fire test room
Annex E (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex F (normative) - Glowing smouldering cotton fire (TF3)
Annex G (normative) - Open plastics (polyurethane) fire (TF4)
Annex H (normative) - Liquid (n-heptane) fire (TF5)
Annex I (informative) - Information concerning the construction
        of the gas test chamber
Annex J (informative) - Construction of the heat tunnel

Describes requirements, test methods, and performance criteria for point multi-sensor fire detectors that incorporate at least one carbon monoxide (CO) sensor in combination with one or more heat sensors, for use in fire detection and alarm systems installed in buildings.

Committee
FSH/12/2
DevelopmentNote
Supersedes 05/30141222 DC. (11/2007)
DocumentType
Standard
Pages
70
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of ISO7240 specifies requirements, test methods, and performance criteria for point multi-sensor fire detectors that incorporate at least one carbon monoxide (CO) sensor in combination with one or more heat sensors, for use in fire detection and alarm systems installed in buildings (see ISO7240-1).

For the testing of other types of CO multi-sensor fire detectors, or CO and heat multi-sensor fire detectors working on different principles, this part of ISO7240 is only to be used for guidance. CO and heat multi-sensor fire detectors with special characteristics and developed for specific risks are not covered by this part of ISO7240.

Standards Relationship
ISO 7240-8:2014 Identical

BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
07/30171700 DC : DRAFT OCT 2007 BS 5839-1 AMD1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE

ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 62599-2:2010 Alarm systems - Part 2: Electromagnetic compatibility - Immunity requirements for components of fire and security alarm systems
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
ISO 7240-5:2012 Fire detection and alarm systems Part 5: Point-type heat detectors
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
ISO 7240-1:2014 Fire detection and alarm systems — Part 1: General and definitions
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more