Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, and abbreviations
4 Requirements
5 Tests
6 Test report
7 Marking
8 Data
Annex A (normative) - Compensation for detector drift
Annex B (normative) - Smoke tunnel for smoke-response
        value measurements
Annex C (normative) - Heat tunnel for heat-response value
        measurements
Annex D (normative) - Apparatus for the dazzling test
Annex E (normative) - Apparatus for the impact test
Annex F (normative) - Fire test room
Annex G (normative) - Open cellulosic (wood) fire (TF1)
Annex H (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex I (normative) - Glowing smouldering cotton fire (TF3)
Annex J (normative) - Flaming plastics (polyurethane) fire (TF4)
Annex K (normative) - Flaming liquid (n-heptane) fire (TF5)
Annex L (normative) - Low-temperature black-smoke liquid
        (decalin) fire (TF8)
Annex M (informative) - Construction of the measuring ionization
        chamber
Annex N (informative) - Construction of the heat tunnel

Defines requirements, test methods, and performance criteria for point-type fire detectors using smoke and heat sensors, incorporating in one mechanical enclosure at least one smoke sensor and at least one other sensor which responds to heat, and in which the signal(s) of the smoke sensor(s) is (are) combined with the signal(s) of the heat sensor(s).

Committee
FSH/12/2
DevelopmentNote
Supersedes 13/30280627 DC. (07/2014)
DocumentType
Standard
Pages
78
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of ISO7240 specifies requirements, test methods, and performance criteria for point-type fire detectors using smoke and heat sensors, incorporating in one mechanical enclosure at least one smoke sensor and at least one other sensor which responds to heat, and in which the signal(s) of the smoke sensor(s) is (are) combined with the signal(s) of the heat sensor(s).

The performance of a single sensor within the detector covered by this part of ISO7240 cannot be sufficient for conformity to other parts of ISO7240 for the single sensor detector.

Certain types of detectors can contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not therefore specified in this standard. However, such detectors are expected to conform to the national requirements and be in line with the recommendations of the Nuclear Energy Agency (NEA) of the Organization for Economic Co-operation and Development (OECD)1.

For the testing of other types of detectors, or detectors working on different principles, this part of ISO7240 can be used only for guidance. Detectors with special characteristics, developed for specific risks, are not covered in this part of ISO7240.

1 OECD, Recommendations for ionization smoke detectors in implementation of radiation protection standards. Nuclear Energy Agency, Organisation for economic Co-operation and Development, Paris, France

Standards Relationship
ISO 7240-15:2014 Identical

BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
07/30171700 DC : DRAFT OCT 2007 BS 5839-1 AMD1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE

ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
ISO 7240-5:2012 Fire detection and alarm systems Part 5: Point-type heat detectors
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
ISO 7240-1:2014 Fire detection and alarm systems — Part 1: General and definitions
ISO 7240-7:2011 Fire detection and alarm systems Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more