BS ISO 7240-15:2014
Current
The latest, up-to-date edition.
Fire detection and alarm systems Point-type fire detectors using smoke and heat sensors
Hardcopy , PDF
English
31-07-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, and abbreviations
4 Requirements
5 Tests
6 Test report
7 Marking
8 Data
Annex A (normative) - Compensation for detector drift
Annex B (normative) - Smoke tunnel for smoke-response
value measurements
Annex C (normative) - Heat tunnel for heat-response value
measurements
Annex D (normative) - Apparatus for the dazzling test
Annex E (normative) - Apparatus for the impact test
Annex F (normative) - Fire test room
Annex G (normative) - Open cellulosic (wood) fire (TF1)
Annex H (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex I (normative) - Glowing smouldering cotton fire (TF3)
Annex J (normative) - Flaming plastics (polyurethane) fire (TF4)
Annex K (normative) - Flaming liquid (n-heptane) fire (TF5)
Annex L (normative) - Low-temperature black-smoke liquid
(decalin) fire (TF8)
Annex M (informative) - Construction of the measuring ionization
chamber
Annex N (informative) - Construction of the heat tunnel
Defines requirements, test methods, and performance criteria for point-type fire detectors using smoke and heat sensors, incorporating in one mechanical enclosure at least one smoke sensor and at least one other sensor which responds to heat, and in which the signal(s) of the smoke sensor(s) is (are) combined with the signal(s) of the heat sensor(s).
Committee |
FSH/12/2
|
DevelopmentNote |
Supersedes 13/30280627 DC. (07/2014)
|
DocumentType |
Standard
|
Pages |
78
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO7240 specifies requirements, test methods, and performance criteria for point-type fire detectors using smoke and heat sensors, incorporating in one mechanical enclosure at least one smoke sensor and at least one other sensor which responds to heat, and in which the signal(s) of the smoke sensor(s) is (are) combined with the signal(s) of the heat sensor(s).
The performance of a single sensor within the detector covered by this part of ISO7240 cannot be sufficient for conformity to other parts of ISO7240 for the single sensor detector.
Certain types of detectors can contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not therefore specified in this standard. However, such detectors are expected to conform to the national requirements and be in line with the recommendations of the Nuclear Energy Agency (NEA) of the Organization for Economic Co-operation and Development (OECD)1.
For the testing of other types of detectors, or detectors working on different principles, this part of ISO7240 can be used only for guidance. Detectors with special characteristics, developed for specific risks, are not covered in this part of ISO7240.
1 OECD, Recommendations for ionization smoke detectors in implementation of radiation protection standards. Nuclear Energy Agency, Organisation for economic Co-operation and Development, Paris, France
Standards | Relationship |
ISO 7240-15:2014 | Identical |
BS 5839-6:2013 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises |
BS 5839-1(2002) : 2002 | FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
12/30260278 DC : 0 | BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
07/30171700 DC : DRAFT OCT 2007 | BS 5839-1 AMD1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
ISO 7240-5:2012 | Fire detection and alarm systems Part 5: Point-type heat detectors |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
ISO 7240-1:2014 | Fire detection and alarm systems — Part 1: General and definitions |
ISO 7240-7:2011 | Fire detection and alarm systems Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |