BS ISO 30011:2010
Current
The latest, up-to-date edition.
Workplace air. Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry
Hardcopy , PDF
English
31-01-2011
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Requirements
6 Reagents
7 Laboratory apparatus
8 Procedure
9 Expression of results
10 Method performance
11 Test report
Annex A (informative) - ICP-MS principles and interferences
Annex B (informative) - Guidance on maintenance of ICP-MS
instrumentation
Annex C (informative) - Recalculation of metal and metalloid
in air concentrations to reference conditions
Bibliography
Defines a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202-1.
Committee |
EH/2/2
|
DevelopmentNote |
Supersedes 09/30165939 DC. (02/2011)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO15202-1. Method development, performance checks, and a routine analysis method are specified. Test solutions for analysis by this International Standard are prepared as specified in ISO15202-2. This International Standard is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values (seee.g. EN689[10], ASTM E1370[8]). The following is a non-exclusive list of metals and metalloids for which limit values have been set (see Reference [15]) and for which one or more of the sample preparation methods specified in ISO15202-2 and the analytical procedure described in this International Standard are applicable. However, there is no information available on the effectiveness of any of these sample preparation methods for those elements listed in italics. aluminium caesium lead platinum tungsten antimony chromium lithium potassium uranium arsenic cobalt magnesium rhodium vanadium barium copper manganese selenium yttrium beryllium gallium mercury silver zinc bismuth germanium molybdenum sodium zirconium boron hafnium nickel tellurium cadmium indium niobium thallium calcium iron phosphorus tin This International Standard is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO15202-1. The procedure is suitable for assessment of exposure against the long-term exposure limits for most of the metals and metalloids listed above when sampling at a typical flow rate of 2l min−1 for sampling times in the range 0,5h to 8h and for assessment of exposure against the short-term exposure limits, where applicable. The procedure is subject to no significant spectral interferences (see A.3), provided that suitable analytical isotopes are used. However, inadequate matrix-matching can adversely affect results.
Standards | Relationship |
ISO 30011:2010 | Identical |
ASTM E 1370 : 2014 : REDLINE | Standard Guide for Air Sampling Strategies for Worker and Workplace Protection |
ISO 8655-5:2002 | Piston-operated volumetric apparatus Part 5: Dispensers |
ISO 8655-1:2002 | Piston-operated volumetric apparatus Part 1: Terminology, general requirements and user recommendations |
ISO 3585:1998 | Borosilicate glass 3.3 — Properties |
ISO 1042:1998 | Laboratory glassware — One-mark volumetric flasks |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
EN 13890:2009 | Workplace exposure - Procedures for measuring metals and metalloids in airborne particles - Requirements and test methods |
ISO 15202-1:2012 | Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 1: Sampling |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO 3534-2:2006 | Statistics — Vocabulary and symbols — Part 2: Applied statistics |
ASTM D 7439 : 2014 : REDLINE | Standard Test Method for Determination of Elements in Airborne Particulate Matter by Inductively Coupled Plasma–Mass Spectrometry |
ISO 9004:2009 | Managing for the sustained success of an organization A quality management approach |
ISO 8655-2:2002 | Piston-operated volumetric apparatus Part 2: Piston pipettes |
EN 1540:2011 | Workplace exposure - Terminology |
ISO 17294-2:2016 | Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of selected elements including uranium isotopes |
ISO 8655-6:2002 | Piston-operated volumetric apparatus Part 6: Gravimetric methods for the determination of measurement error |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 15202-2:2012 | Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 2: Sample preparation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.