BS IEC 62873-3-2:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Residual current operated circuit-breakers for household and similar use Particular requirements for RCDs with flat quick-connect terminations
Hardcopy , PDF
27-11-2020
English
30-09-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Characteristics of RCDs
6 Marking and other product information
7 Standard conditions for operation in service
and for installation
8 Requirements for construction and operation
9 Tests
Bibliography
Pertains to RCDs equipped with flat quick-connect terminations consisting of a male tab with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer's instructions, for rated currents up to and including 16 A.
Committee |
PEL/23/1
|
DevelopmentNote |
Supersedes 13/30283468 DC. (09/2016)
|
DocumentType |
Standard
|
Pages |
18
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of IEC 62873 applies to RCDs equipped with flat quick-connect terminations consisting of a male tab (see 3.2) with nominal width 6,3 mm and thickness 0,8 mm, to be used with a mating female connector for connecting electrical copper conductors according to the manufacturer\'s instructions, for rated currents up to and including 16 A.
NOTE The use of RCDS with flat quick-connect terminations for rated currents up to and including 20 A is accepted in BE, FR, IT, ES, PT and US.
This part of IEC 62873 cannot be used alone but is intended to be applied together with an RCD product standard (IEC 61008-1 or IEC 61009-1) if an RCD is equipped with flat quick-connect terminations.
The connectable electrical copper conductors are flexible, having a cross-sectional area up to and including 4 mm2, or rigid stranded, having a cross-sectional area up to and including 2,5 mm2 (AWG equal to or greater than 12).
This part of IEC 62873 applies exclusively to RCDs having male tabs as an integral part of the device.
Standards | Relationship |
IEC 62873-3-2:2016 | Identical |
IEC 62873-2:2016 | Residual current operated circuit-breakers for household and similar use - Part 2: Residual current devices (RCDs) - Vocabulary |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.