BS IEC 61892-1:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Mobile and fixed offshore units. Electrical installations General requirements and conditions

Available format(s)

Hardcopy , PDF

Superseded date

01-05-2019

Superseded by

BS IEC 61892-1:2019

Language(s)

English

Published date

31-07-2015

$443.41
Including GST where applicable

Committee
JPEL/18
DevelopmentNote
Supersedes 99/200415 DC (07/2002) Supersedes 09/30200619 DC. (12/2010) Supersedes 14/30293263 DC. (07/2015)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of IEC61892 contains provisions for electrical installations in mobile and fixed offshore units including pipeline, pumping or \'pigging\' stations, compressor stations and exposed location single buoy moorings, used in the offshore petroleum industry for drilling, processing and storage purposes. This International Standard applies to all installations, whether permanent, temporary, transportable or hand-held, to AC installations up to and including 35000V and DC installations up to and including 1500V (AC and DC voltages are nominal values). This standard does not apply either to fixed equipment for medical purposes or to the electrical installations of tankers. NOTE For medical rooms, IEC60364‑7‑710 provides more information.

Standards Relationship
IEC 61892-1:2015 Identical

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
ISO 9223:2012 Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation
ISO 12944-6:1998 Paints and varnishes Corrosion protection of steel structures by protective paint systems Part 6: Laboratory performance test methods
IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
IEC 60364-7-710:2002 Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
ISO 12944-5:2007 Paints and varnishes Corrosion protection of steel structures by protective paint systems Part 5: Protective paint systems
IEC 61892-7:2014 Mobile and fixed offshore units - Electrical installations - Part 7: Hazardous areas
IMO IF110 : 2014 SUPP 2016 SOLAS CONSOLIDATED EDITION
IEC 61892-5:2014 Mobile and fixed offshore units - Electrical installations - Part 5: Mobile units
ISO 4628-4:2016 Paints and varnishes Evaluation of degradation of coatings Designation of quantity and size of defects, and of intensity of uniform changes in appearance Part 4: Assessment of degree of cracking
ISO 4628-3:2016 Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 3: Assessment of degree of rusting
IEC 61892-2:2012 Mobile and fixed offshore units - Electrical installations - Part 2: System design
IMO IA811 : 2001 MOBILE OFFSHORE DRILLING UNITS (MODU) CODE, CONSOLIDATED
IEC 61892-3:2012 Mobile and fixed offshore units - Electrical installations - Part 3: Equipment
ISO 12944-1:2017 Paints and varnishes — Corrosion protection of steel structures by protective paint systems — Part 1: General introduction
ISO 4628-5:2016 Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 5: Assessment of degree of flaking
ISO 4628-1:2016 Paints and varnishes Evaluation of degradation of coatings Designation of quantity and size of defects, and of intensity of uniform changes in appearance Part 1: General introduction and designation system
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO 12944-4:2017 Paints and varnishes — Corrosion protection of steel structures by protective paint systems — Part 4: Types of surface and surface preparation
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 61892-6:2013 Mobile and fixed offshore units - Electrical installations - Part 6: Installation
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 60721-3-6:1987 Classification of environmental conditions. Part 3: Classification of groups of environmental parameters and their severities. Ship environment
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
ISO 4628-2:2016 Paints and varnishes Evaluation of degradation of coatings Designation of quantity and size of defects, and of intensity of uniform changes in appearance Part 2: Assessment of degree of blistering

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more