BS EN ISO 52022-1:2017
Current
The latest, up-to-date edition.
Energy performance of buildings. Thermal, solar and daylight properties of building components and elements Simplified calculation method of the solar and daylight characteristics for solar protection devices combined with glazing
Hardcopy , PDF
English
14-08-2017
Committee |
B/540/8
|
DevelopmentNote |
Supersedes 15/30312819 DC & BS EN 13363-1. (08/2017)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This document specifies a simplified method based on thermal, solar and light characteristics of the glazing and solar and light characteristics of the solar protection device, to estimate the total solar energy transmittance, direct energy transmittance and the light transmittance of a solar protection device combined to a glazing.
This document is applicable to all types of solar protection devices parallel to the glazing, such as louvre, venetian or roller blinds. The position of the solar protection device can be interior, exterior or between single panes in a dual glazing system. It is applicable when the total solar energy transmittance of the glazing is between 0,15 and 0,85. Venetian or louvre blinds are assumed to be adjusted so that there is no direct solar penetration. It is assumed that for external solar protection devices and for integrated solar protection devices, the space between the solar protection devices and the glazing is unventilated and for internal solar protection devices this space is ventilated.
The resulting g-values of the simplified method given here are approximate and their deviation from the exact values lie within the range between +0,10 and -0,02. The results generally tend to lie on the safe side for cooling load estimations. The results are not intended to be used for calculating beneficial solar gains or thermal comfort criteria.
The simplified method is based on the normal incidence of radiation and does not take into account either the angular dependence of transmittance and the reflectance or the differences of spectral distribution. This should be considered when applying the method.
The simplified method can also be used for inclined elements.
This document can be applied when the solar transmittance and solar reflectance of the solar protection devices are within the following ranges:
0 ≤ τ e,B ≤ 0,5 and 0,1 ≤ ρ e,B ≤ 0,8
For reflectance and transmittance values outside these ranges ISO 52022-3 applies.
For cases not covered by the method given in this document more exact calculations based on the optical properties (in general the spectral data) of glass and solar protection device can be carried out in accordance with ISO 52022-3.
NOTE Table1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
Standards | Relationship |
EN ISO 52022-1:2017 | Identical |
ISO 52022-1:2017 | Identical |
CEN/TS 16629:2014 | Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards |
ISO 10293:1997 | Glass in building — Determination of steady-state U values (thermal transmittance) of multiple glazing — Heat flow meter method |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
CEN/TS 16628:2014 | Energy Performance of Buildings - Basic Principles for the set of EPB standards |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
ISO 52022-3:2017 | Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing |
ISO 52000-1:2017 | Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures |
EN 14500:2008 | Blinds and shutters - Thermal and visual comfort - Test and calculation methods |
ISO 10291:1994 | Glass in building — Determination of steady-state U values (thermal transmittance) of multiple glazing — Guarded hot plate method |
EN 674:2011 | Glass in building - Determination of thermal transmittance (U value) - Guarded hot plate method |
ISO 9050:2003 | Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors |
EN 675:2011 | Glass in building - Determination of thermal transmittance (U value) - Heat flow meter method |
ISO/TR 52000-2:2017 | Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1 |
ISO/TR 52022-2:2017 | Energy performance of buildings Thermal, solar and daylight properties of building components and elements Part 2: Explanation and justification |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |
ISO 10292:1994 | Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing |