Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN ISO 52016-1:2017

Current

Current

The latest, up-to-date edition.

Energy performance of buildings. Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Calculation procedures

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

02-10-2017

$669.38
Including GST where applicable

Committee
B/540/8
DevelopmentNote
Supersedes 15/30303577 DC & BS EN ISO 13790. Together with BS EN ISO 52017-1, it supersedes BS EN 15265, BS EN 15255, BS EN ISO 13791 and BS EN ISO 13792. (10/2017)
DocumentType
Standard
Pages
218
PublisherName
British Standards Institution
Status
Current
Supersedes

This document specifies calculation methods for the assessment of: the (sensible) energy need for heating and cooling, based on hourly or monthly calculations; the latent energy need for (de-)humidification, based on hourly or monthly calculations; the internal temperature, based on hourly calculations; the sensible heating and cooling load, based on hourly calculations; the moisture and latent heat load for (de-)humidification, based on hourly calculations; the design sensible heating or cooling load and design latent heat load using an hourly calculation interval; the conditions of the supply air to provide the necessary humidification and dehumidification. The calculation methods can be used for residential or non-residential buildings, or a part of it, referred to as “the building” or the \'assessed object\'. This document also contains specifications for the assessment of thermal zones in the building or in the part of a building. The calculations are performed per thermal zone. In the calculations, the thermal zones can be assumed to be thermally coupled or not. The calculation methods have been developed for the calculation of the basic energy loads and needs, without interaction with specific technical building systems, and for the calculation of the system specific energy loads and needs, including the interaction with specific systems. The hourly calculation procedures can also be used as basis for calculations with more extensive system control options. This document is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase. NOTE Table 1 in the Introduction shows the relative position of this document within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.

Standards Relationship
ISO 52016-1:2017 Identical
EN ISO 52016-1:2017 Identical

ISO 13789:2017 Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method
CEN/TS 16629:2014 Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards
ISO 13792:2012 Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling Simplified methods
EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
CEN/TS 16628:2014 Energy Performance of Buildings - Basic Principles for the set of EPB standards
ISO 9488:1999 Solar energy Vocabulary
EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
ISO 52022-3:2017 Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing
ISO 15927-4:2005 Hygrothermal performance of buildings — Calculation and presentation of climatic data — Part 4: Hourly data for assessing the annual energy use for heating and cooling
ISO 15099:2003 Thermal performance of windows, doors and shading devices — Detailed calculations
ISO 52000-1:2017 Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures
ISO 52017-1:2017 Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures
ISO 15927-5:2004 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 5: Data for design heat load for space heating
ISO 52010-1:2017 Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations
ISO/TR 52016-2:2017 Energy performance of buildings Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
ISO/TR 52019-2:2017 Energy performance of buildings Hygrothermal performance of building components and building elements Part 2: Explanation and justification
ISO 9050:2003 Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
EN 12831-1:2017 Energy performance of buildings - Method for calculation of the design heat load - Part 1: Space heating load, Module M3-3
ISO 13786:2017 Thermal performance of building components — Dynamic thermal characteristics — Calculation methods
ISO 13370:2017 Thermal performance of buildings — Heat transfer via the ground — Calculation methods
ISO/TR 52000-2:2017 Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1
ISO 13791:2012 Thermal performance of buildings Calculation of internal temperatures of a room in summer without mechanical cooling General criteria and validation procedures
EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
ISO 15927-2:2009 Hygrothermal performance of buildings Calculation and presentation of climatic data Part 2: Hourly data for design cooling load
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods
ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
ISO 13790:2008 Energy performance of buildings Calculation of energy use for space heating and cooling
ASHRAE 140 : 2014 METHOD OF TEST FOR THE EVALUATION OF BUILDING ENERGY ANALYSIS COMPUTER PROGRAMS
ISO 7345:1987 Thermal insulation Physical quantities and definitions
ISO 10292:1994 Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.