BS EN ISO 5167-2:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Orifice plates

Available format(s)

Hardcopy , PDF

Superseded date

07-07-2022

Superseded by

BS EN ISO 5167-2:2022

Language(s)

English

Published date

18-03-2003

$618.22
Including GST where applicable

Committee
CPI/30/2
DevelopmentNote
Supersedes 98/121140 DC Together with 2003 Version of BS EN ISO 5167-1, BS EN ISO 5167-3, and BS EN ISO 5167-4 supersedes the 1997 Version of BS EN ISO 5167-1. (03/2003)
DocumentType
Standard
Pages
58
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of ISO 5167 specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit.

This part of ISO 5167 also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in ISO 5167-1.

This part of ISO 5167 is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as “vena contracta” and pipe tappings have been used with orifice plates but are not covered by this part of ISO 5167. This part of ISO 5167 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or for pipe Reynolds numbers below 5 000.

BS 7965:2009 Guide to the selection, installation, operation and calibration of diagonal path transit time ultrasonic flowmeters for industrial gas applications

ISO/TR 5168:1998 Measurement of fluid flow Evaluation of uncertainties
ISO/TR 3313:1998 Measurement of fluid flow in closed conduits Guidelines on the effects of flow pulsations on flow-measurement instruments
ISO/TR 9464:2008 Guidelines for the use of ISO 5167:2003
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
ISO 4006:1991 Measurement of fluid flow in closed conduits — Vocabulary and symbols

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more