BS EN ISO 11137-2:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Sterilization of health care products. Radiation Establishing the sterilization dose
Hardcopy , PDF
21-04-2023
English
30-06-2015
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, and abbreviated terms
4 Definition and maintenance of product families
for dose setting, dose substantiation, and sterilization
dose auditing
5 Selection and testing of product for establishing
the sterilization dose
6 Methods of dose establishment
7 Method 1: dose setting using bioburden information
8 Method 2: Dose setting using fraction positive
information from incremental dosing to
determine an extrapolation factor
9 Method VD[max] - Substantiation of 25 kGy or
15 kGy as the sterilization dose
10 Sterilization dose audit
11 Worked examples
Annex ZA (informative) - Relationship between
this European Standard and the Essential
Requirements of EU Directive 90/385/EEC
on active implantable medical devices
Annex ZB (informative) - Relationship between
this European Standard and the Essential
Requirements of EU Directive 93/42/EEC
on medical devices
Annex ZC (informative) - Relationship between
this European Standard and the Essential
Requirements of EU Directive 98/79/EC
on in vitro diagnostic medical devices
Bibliography
Describes methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the sterilization dose to achieve a sterility assurance level, SAL, of 10[-6].
Committee |
CH/198
|
DevelopmentNote |
Together with BS EN ISO 11137-1 and BS EN ISO 11137-3, it supersedes BS EN 552. Supersedes 04/30048584 DC. (07/2007) Supersedes 09/30197784 DC. (06/2015)
|
DocumentType |
Standard
|
Pages |
84
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This part of ISO 11137 specifies methods for determining the minimum dose needed to achieve a specified requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the sterilization dose to achieve a sterility assurance level, SAL, of 10−6. This part of ISO 11137 also specifies methods of sterilization dose audit used to demonstrate the continued effectiveness of the sterilization dose.
This part of ISO 11137 defines product families for sterilization dose establishment and sterilization dose audit.
Standards | Relationship |
ONORM EN ISO 11137-2 : 2015 | Identical |
UNI EN ISO 11137-2 : 2013 | Identical |
NF EN ISO 11137-2 : 2015 | Identical |
UNE-EN ISO 11137-2:2015 | Identical |
NEN EN ISO 11137-2 : 2015 | Identical |
I.S. EN ISO 11137-2:2015 | Identical |
EN ISO 11137-2:2015 | Identical |
NS EN ISO 11137-2 : 2015 | Identical |
SN EN ISO 11137-2:2015 | Identical |
NBN EN ISO 11137-2 : 2015 | Identical |
ISO 11137-2:2013 | Identical |
DIN EN ISO 11137-2:2015-11 | Identical |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 11737-2:2009 | Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
AAMI TIR27 : 1ED 2001 | STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION STERILIZATION - SUBSTANTIATION OF 25 KGY AS A STERILIZATION DOSE - METHOD VD MAX |
AAMI ST32 : 1991 | GUIDELINE FOR GAMMA RADIATION STERILIZATION |
ISO/TS 11139:2006 | Sterilization of health care products Vocabulary |
ISO 11137-3:2017 | Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11137:1995 | Sterilization of health care products Requirements for validation and routine control Radiation sterilization |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.