INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements on tests
5 Marking
6 Dimensions
7 Test conditions
8 Lamp input
9 Light output
10 Colour nomenclature, variation and rendering
11 Lamp life
12 Verification
Annex A (normative) - Method of measuring
        lamp characteristics
Annex B (normative) - Explanation of the
        photometric code
Annex C (normative) - Measurement of
        displacement factor
Annex D (informative) - Explanation of
        displacement factor
Annex E (informative) - Explanation of
        recommended life time metrics
Annex F (informative) - Examples of LED
        dies and LED packages
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Describes the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having: - a rated power up to 60 W; - a rated voltage of > 50 V a.c. up to 250 V a.c.; and - a lamp cap as listed in IEC 62560.

Committee
CPL/34/1
DevelopmentNote
Supersedes DD IEC PAS 62612 & 09/30204072 DC. (09/2013)
DocumentType
Standard
Pages
46
ProductNote
THE CONSOLIDATED VERSION AVAILABLE NOW FOR THIS STANDARD THIS STANDARD ALSO REFERS TO ANSI/IES LM-80-15,CIE 121,CIE 13.2,CIE 13.3,CIE 177,CIE S 017/E,IES LM-79-08,CIE 84:1989
PublisherName
British Standards Institution
Status
Current
Supersedes

This International Standard specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having: a rated power up to 60W; a rated voltage of > 50V a.c. up to 250V a.c.; a lamp cap as listed in IEC62560. These performance requirements are additional to the safety requirements in IEC62560. The only feature provided by this standard, when applied for replacement purposes, is information on maximum lamp outlines. The requirements of this standard relate to type testing. This standard covers LED lamps that intentionally produce white light, based on inorganic LEDs. Recommendations for whole product testing or batch testing are under consideration. The life time of LED lamps is in most cases much longer than the practical test times. Consequently, verification of manufacturer’s life time claims cannot be made in a sufficiently confident way, because projecting test data further in time is not standardised. For that reason the acceptance or rejection of a manufacturer’s life time claim, past an operational time as stated in 7.1, is out of the scope of this standard. Instead of life time validation, this standard has opted for lumen maintenance codes at a defined finite test time. Therefore, the code number does not imply a prediction of achievable life time. The categories, represented by the code, are lumen-depreciation character categories showing behaviour in agreement with manufacturer’s information, provided before the test is started. In order to validate a life time claim, several methods of test data extrapolation exist. A general method of projecting measurement data beyond limited test time is under consideration. The pass/fail criterion of the life time test as defined in this standard is different from the life time metrics claimed by manufacturers. For explanation of recommended life time metrics, see AnnexE. NOTE When lamps are operated in a luminaire the claimed performance data can deviate from the values established via this standard due to e.g. luminaire components that impact the performance of the lamp. It can be expected that self-ballasted LED lamps, which comply with this standard will start and operate satisfactorily at voltages between 92%and 106%of rated supply voltage and at an ambient air temperature between −20°C and 40°C and in a luminaire complying with IEC60598-1. If a supplier claims suitability for operation at different conditions (for instance, at higher voltage, temperature or humidity) then: Lamps shall be tested under claimed different conditions; and Lamps shall start and operate satisfactorily under claimed different conditions; and Lamps shall meet the performance claims under the claimed different conditions, which may differ from the general conditions for measurement specified in A.1. 1.0.Z1 Overall statement Where a Commission Regulation specifies limits for parameters these limits shall be used instead of the limits specified in this standard.

Standards Relationship
EN 62612:2013/A2:2018 Identical
IEC 62612:2013/AMD2:2018 Identical
EN 62612:2013/A11:2017/AC:2017-11 Identical

IEC 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
IEC TR 62732:2012 Three-digit code for designation of colour rendering and correlated colour temperature
IEC TR 61341:2010 Method of measurement of centre beam intensity and beam angle(s) of reflector lamps
EN 60630:1998/A7:2015 MAXIMUM LAMP OUTLINES FOR INCANDESCENT LAMPS (IEC 60630:1994/A7:2014, MODIFIED)
CISPR 15:2013+AMD1:2015 CSV Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
IEC PAS 62717:2011 LED modules for general lighting - Performance requirements
IEC TS 62504:2011 General lighting - LEDs and LED modules - Terms and definitions
EN 61000-4-7:2002/A1:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-7: TESTING AND MEASUREMENT TECHNIQUES - GENERAL GUIDE ON HARMONICS AND INTERHARMONICS MEASUREMENTS AND INSTRUMENTATION, FOR POWER SUPPLY SYSTEMS AND EQUIPMENT CONNECTED THERETO (IEC 61000-4-7:2002/A1:2008)
EN 61341:2011 Method of measurement of centre beam intensity and beam angle(s) of reflector lamps
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV Single-capped fluorescent lamps - Performance specifications
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-4-7:2002+AMD1:2008 CSV Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto
ANSI C78.377 : 2015 ELECTRIC LAMPS - SPECIFICATIONS FOR THE CHROMATICITY OF SOLID-STATE LIGHTING PRODUCTS
IEC 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
EN 60068-2-14:2009 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 62560:2011+AMD1:2015 CSV Self-ballasted LED-lamps for general lighting services by voltage >50 V - Safety specifications
IES LM 79 : 2008 ELECTRICAL AND PHOTOMETRIC MEASUREMENTS OF SOLID-STATE LIGHTING PRODUCTS
IEC 60630:2005 CSV Maximum lamp outlines for incandescent lamps

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more