BS EN 62561-3:2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lightning protection system components (LPSC) Requirements for isolating spark gaps (ISG)
Hardcopy , PDF
07-09-2023
English
28-09-2017
Committee |
GEL/81
|
DevelopmentNote |
Supersedes BS EN 50164-3. Supersedes 07/30174370 DC. (06/2012) Supersedes 15/30326953 DC. (10/2017)
|
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of IEC62561 specifies the requirements and tests for isolating spark gaps (ISG) for lightning protection systems. ISGs can be used to indirectly bond a lightning protection system to other nearby metalwork where a direct bond is not permissible for functional reasons. Typical applications include the connection to earth-termination systems of power installations, earth-termination systems of telecommunication systems, auxiliary earth electrodes of voltage-operated, earth fault circuit breakers, rail earth electrode of power and DC railways, measuring earth electrodes for laboratories, installations with cathodic protection and stray current systems, service entry masts for low-voltage overhead cables, bypassing insulated flanges and insulated couplings of pipelines. This does not cover applications where follow currents occur. NOTE Lightning protection system components (LPSC) can also be suitable for use in hazardous conditions such as fire and explosive atmosphere. Due regard will be taken of the extra requirements necessary for the components to be installed in such conditions.
Standards | Relationship |
EN 62561-3:2017 | Identical |
IEC 62561-3:2017 | Identical |
EN 62271-204:2011 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 62561-1:2017 | Lightning protection system components (LPSC) - Part 1: Requirements for connection components |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO 4892-3:2016 | Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps |
IEC 61643-11:2011 | Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods |
ISO 4892-4:2013 | Plastics — Methods of exposure to laboratory light sources — Part 4: Open-flame carbon-arc lamps |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
EN 62561-1:2017 | Lightning Protection System Components (LPSC) - Part 1: Requirements for connection components |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
ISO 6957:1988 | Copper alloys Ammonia test for stress corrosion resistance |