BS EN 62387-1:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Radiation protection instrumentation. Passive integrating dosimetry systems for environmental and personal monitoring General characteristics and performance requirements
Hardcopy , PDF
31-03-2016
English
30-11-2012
Foreword
Introduction
1 Scope and object
2 Normative references
3 Terms and definitions
4 Units and symbols
5 General test procedures
6 Performance requirements: summary
7 Capability of a dosimetry system
8 Requirements for the design of the dosimetry
system
9 Instruction manual
10 Software, data and interfaces of the dosimetry
system
11 Radiation performance requirements and tests
(dosimetry system)
12 Response to mixed irradiations (dosimetry system)
13 Environmental performance requirements and tests
14 Electromagnetic performance requirements and
tests (dosimetry system)
15 Mechanical performance requirements and tests
16 Documentation
Annex A (normative) - Confidence limits
Annex B (informative) - Causal connection between
readout signals, indicated value and
measured value
Annex C (informative) - Overview of the necessary
actions that have to be performed for a
type test according to this standard
Annex D (informative) - Usage categories of passive
dosemeters
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZB (informative) - Uncertainty of dosimetry
systems
Annex ZC (informative) - Conversion coefficients h[pk]
(0.07;S,alpha) and h[pK](0.07;R,alpha) from air
kerma, K[a], to the dose equivalent H[p](0.07)
for radiation qualities defined in ISO 4037-1
and the rod, pillar and slab phantom
Annex ZD (informative) - Computational method of test
for mixed irradiations
Bibliography
Pertains to all kinds of passive dosimetry systems that are used for measuring: - the personal dose equivalent H[p](10) (for whole body dosimetry), - the personal dose equivalent H[p](0,07) (for both whole body and extremity dosimetry), or - the ambient dose equivalent H*(10) (for environmental dosimetry).
Committee |
NCE/2
|
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Applies to dosimetry systems that are capable of evaluating doses in the required quantity and unit (Sv) from readout signals in any quantity and unit. The only correction that may be applied to the evaluated dose (indicated value) is the one resulting from natural background radiation using extra dosemeters.
Standards | Relationship |
EN 62387-1:2012 | Identical |
EN 60904-3:2016 | Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data |
IEC TR 62461:2015 | Radiation protection instrumentation - Determination of uncertainty in measurement |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
ISO 4037-4:2004 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields |
ISO 6980-3:2006 | Nuclear energy — Reference beta-particle radiation — Part 3: Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence |
ISO 6980-2:2004 | Nuclear energy — Reference beta-particle radiation — Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field |
EN 60359:2002 | Electrical and electronic measurement equipment - Expression of performance |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
ISO 12794:2000 | Nuclear energy Radiation protection Individual thermoluminescence dosemeters for extremities and eyes |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO 8529-3:1998 | Reference neutron radiations — Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
ISO 8529-2:2000 | Reference neutron radiations Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60904-3:2016 | Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data |
ISO 6980-1:2006 | Nuclear energy — Reference beta-particle radiation — Part 1: Methods of production |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
ISO 8529-1:2001 | Reference neutron radiations Part 1: Characteristics and methods of production |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
IEC 60050-393:2003 | International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.