FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Normal and special service conditions
5 Ratings and classifications
6 Design and construction
7 Type tests
8 Routine tests
9 Information to be given with enquiries,
tenders and orders
10 Rules for transport, storage, installation,
operation and maintenance
11 Safety
Annex A (normative) - Test overview table
Annex B (normative) - Electronic nameplates
Annex C (informative) - Test procedures - Performance type
testing
Bibliography
Pertains to high-voltage switchgear and controlgear for all rated voltage levels above 1 kV and assemblies thereof and specifies equipment for digital communication with other parts of the power utility automation and its impact on testing.
Committee |
PEL/17
|
DevelopmentNote |
Supersedes 04/30092543 DC (12/2006) Supersedes 12/30265386 DC. (05/2015)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
IEC 62271-3:2015 is applicable to high-voltage switchgear and controlgear for all rated voltage levels above 1 kV and assemblies thereof and specifies equipment for digital communication with other parts of the power utility automation and its impact on testing. This equipment for digital communication, replacing metal parallel wiring, can be integrated into the high-voltage switchgear, controlgear, and assemblies thereof, or can be external equipment in order to provide compliance for existing switchgear and controlgear and assemblies thereof with the standards of the IEC 61850 series. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) an update to the latest edition(s) of IEC 61850 series; (e.g. Annex B \'LNs for sensors and monitoring\' of edition 1 has been deleted since these LNs are now covered by standard IEC 61850-7-4:2010)
b) an update of normative references;
c) the minimum voltage range this standard refers to, was changed from 72,5 kV to above 1 kV;
d) the description of performance tests and conformance tests became more specific;
e) the new - informative - Annex C gives an example for performance type testing;
f) 6.2.3 \'transmission systems\' as well as appropriate subclauses have been superseded by standard IEC TR 61850-90-4:2013;
g) fibre optical connector type LC becomes only recommended type of fibre optic connector in accordance with IEC TR 61850-90-4:2013;
h) electronic nameplates have been redefined as extension of LN XCBR and LN XSWI with data objects, reflecting required additional name plate information.
Standards | Relationship |
NBN EN 62271-3 : 2015 | Identical |
UNE-EN 62271-3:2007 | Identical |
EN 62271-3:2015 | Identical |
NF EN 62271-3 : 2015 | Identical |
IEC 62271-3:2015 | Identical |
DIN EN 62271-3 : 2016 | Identical |
I.S. EN 62271-3:2015 | Identical |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
EN 62271-104:2015 | High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages higher than 52 kV |
HD 546.4 : 200S1 | TELECONTROL EQUIPMENT AND SYSTEMS - PERFORMANCE REQUIREMENTS |
IEC 61850-5:2013 | Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models |
EN 61850-6:2010 | Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs |
IEC 61850-7-2:2010 | Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI) |
ISO/IEC 7498-1:1994 | Information technology Open Systems Interconnection Basic Reference Model: The Basic Model |
IEC 62271-202:2014 | High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation |
IEC 61850-7-410:2012+AMD1:2015 CSV | Communication networks and systems for power utility automation - Part 7-410: Basic communication structure - Hydroelectric power plants - Communication for monitoring and control |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 61850-6:2009 | Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
EN 61850-7-2:2010 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-2: BASIC INFORMATION AND COMMUNICATION STRUCTURE - ABSTRACT COMMUNICATION SERVICE INTERFACE (ACSI) |
EN 62271-102:2002/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013) |
EN 61850-10:2013 | Communication networks and systems for power utility automation - Part 10: Conformance testing |
ISO/IEC 8802-3:2000 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
EN 61850-7-410:2013/A1:2016 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-410: BASIC COMMUNICATION STRUCTURE - HYDROELECTRIC POWER PLANTS - COMMUNICATION FOR MONITORING AND CONTROL (IEC 61850-7-410:2012/A1:2015) |
EN 62271-202:2014/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014) |
EN 61850-5:2013 | Communication networks and systems for power utility automation - Part 5: Communication requirements for functions and device models |
IEC TR 62271-302:2010 | High-voltage switchgear and controlgear - Part 302: Alternating current circuit-breakers with intentionally non-simultaneous pole operation |
IEC 60870-4:1990 | Telecontrol equipment and systems. Part 4: Performance requirements |
IEC TR 61850-1:2013 | Communication networks and systems for power utility automation - Part 1: Introduction and overview |
EN 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
EN 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC 61869-9:2016 | Instrument transformers - Part 9: Digital interface for instrument transformers |
IEC 61850-7-1:2011 | Communication networks and systems for power utility automation - Part 7-1: Basic communication structure - Principles and models |
EN 61850-7-1:2011 | COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 7-1: BASIC COMMUNICATION STRUCTURE - PRINCIPLES AND MODELS (IEC 61850-7-1:2011) |
IEC 61850-8-1:2011 | Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
IEC TR 62063:1999 | High-voltage switchgear and controlgear - The use of electronic and associated technologies in auxiliary equipment of switchgear and controlgear |
EN 61850-7-3:2011 | Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes |
EN ISO/IEC 7498-1 : 1995 | INFORMATION TECHNOLOGY - OPEN SYSTEMS INTERCONNECTION - BASIC REFERENCE MODEL: THE BASIC MODEL |
IEC 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC 61850-9-2:2011 | Communication networks and systems for power utility automation - Part 9-2: Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3 |
EN 61850-3:2014 | Communication networks and systems for power utility automation - Part 3: General requirements |
IEC 61850-4:2011 | Communication networks and systems for power utility automation - Part 4: System and project management |
IEC 61850-7-420:2009 | Communication networks and systems for power utility automation - Part 7-420: Basic communication structure - Distributed energy resources logical nodes |
ISO/IEC 8823-2:1997 | Information technology Open Systems Interconnection Connection-oriented presentation protocol: Protocol Implementation Conformance Statement (PICS) proforma |
EN 61850-7-420:2009 | Communication networks and systems for power utility automation - Part 7-420: Basic communication structure - Distributed energy resources logical nodes |
IEC 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 61850-7-3:2010 | Communication networks and systems for power utility automation - Part 7-3: Basic communication structure - Common data classes |
EN 61850-4:2011 | Communication networks and systems for power utility automation - Part 4: System and project management |
IEC 61850-10:2012 | Communication networks and systems for power utility automation - Part 10: Conformance testing |
IEC 61754-20:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 20: Type LC connector family |
ISO/IEC 8802-2:1998 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Specific requirements — Part 2: Logical link control |
EN 61850-9-2:2011 | Communication networks and systems for power utility automation - Part 9-2: Specific communication service mapping (SCSM) - Sampled values over ISO/IEC 8802-3 |
IEC TS 61850-2:2003 | Communication networks and systems in substations - Part 2: Glossary |
EN 61850-8-1:2011 | Communication networks and systems for power utility automation - Part 8-1: Specific communication service mapping (SCSM) - Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 |
IEC 61850-3:2013 | Communication networks and systems for power utility automation - Part 3: General requirements |
IEC 62271-104:2015 | High-voltage switchgear and controlgear - Part 104: Alternating current switches for rated voltages higher than 52 kV |
EN 61754-20:2012 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 20: Type LC connector family |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.