BS EN 62271-202:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation
Hardcopy , PDF
08-09-2022
English
31-07-2015
Committee |
PEL/17
|
DevelopmentNote |
Supersedes BS EN 61330 & 02/714212 DC. (03/2007) Supersedes 11/30253145 DC. (06/2014)
|
DocumentType |
Standard
|
Pages |
100
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of IEC62271 specifies the service conditions, rated characteristics, general structural requirements and test methods of high voltage/low voltage or low voltage/high voltage prefabricated substations, which are cable-connected, to be operated from inside (walk-in type) or outside (non-walk-in type) for alternating current of rated voltages above 1kV and up to and including 52kV on the high voltage side, and for one or more transformers for service frequencies up to and including 60Hz for outdoor installation at locations with public accessibility and where protection of personnel is provided. Prefabricated substations can be situated at ground level or partially or completely below ground level. In general a prefabricated substation comprises an enclosure containing the following electrical components: power transformers; high voltage and low voltage switchgear and controlgear; high voltage and low voltage interconnections; auxiliary equipment and circuits. However, relevant provisions of this standard are applicable to designs where not all these electrical components exist (for example, an installation consisting of power transformer and low voltage switchgear). Non-prefabricated substations should comply with the applicable requirements of IEC61936‑1:2010 .
Standards | Relationship |
NF EN 62271-202 : 2014 | Identical |
EN 61810-2-1:2011 | Identical |
IEC 62271-202:2014/COR1:2015 | Identical |
EN 62271-202:2014/AC:2014 | Identical |
UNE-EN 62271-202:2015 | Identical |
IEC 62271-202:2014 | Identical |
DIN EN 62271-202 : 2015 | Identical |
I.S. EN 62271-202:2014 | Identical |
NBN EN 62271-202 : 2014 COR 2015 | Identical |
EN 62271-202:2014 | Equivalent |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 60721-1:1990+AMD1:1992+AMD2:1995 CSV | Classification of environmental conditions - Part 1: Environmental parameters and their severities |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
EN ISO 6508-1:2016 | Metallic materials - Rockwell hardness test - Part 1: Test method (ISO 6508-1:2016) |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
ISO 11408:1999 | Chemical conversion coatings Black oxide coating on iron and steel Specification and test methods |
ISO 1716:2010 | Reaction to fire tests for products Determination of the gross heat of combustion (calorific value) |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
EN ISO 3231:1997 | Paints and varnishes - Determination of resistance to humid atmospheres containing sulfur dioxide (ISO 3231:1993) |
EN ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009) |
IEC GUIDE 117:2010 | Electrotechnical equipment - Temperatures of touchable hot surfaces |
CLC/TR 62271-208:2010 | High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
EN 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
ISO 6508-1:2016 | Metallic materials — Rockwell hardness test — Part 1: Test method |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
EN 60076-13 : 2006 | POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID-FILLED TRANSFORMERS |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
EN ISO 1182:2010 | Reaction to fire tests for products - Non-combustibility test (ISO 1182:2010) |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN ISO 2409:2013 | Paints and varnishes - Cross-cut test (ISO 2409:2013) |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
EN 62271-202:2014/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION (IEC 62271-202:2014) |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
IEC TR 62271-300:2006 | High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers |
EN ISO 9227:2017 | Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2017) |
IEC TR 62655:2013 | Tutorial and application guide for high-voltage fuses |
ISO 1052:1982 | Steels for general engineering purposes |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
ISO 2081:2008 | Metallic and other inorganic coatings Electroplated coatings of zinc with supplementary treatments on iron or steel |
ISO 1182:2010 | Reaction to fire tests for products Non-combustibility test |
EN ISO 13732-1:2008 | Ergonomics of the thermal environment - Methods for the assessment of human responses to contact with surfaces - Part 1: Hot surfaces (ISO 13732-1:2006) |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
IEC TS 62271-304:2008 | High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and includuing 52 kV to be used in severe climatic conditions |
ISO 10546:1993 | Chemical conversion coatings Rinsed and non-rinsed chromate conversion coatings on aluminium and aluminium alloys |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60721-2-2:2012 | Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
EN ISO 1460:1994 | Metallic coatings - Hot dip galvanized coatings on ferrous materials - Gravimetric determination of the mass per unit area (ISO 1460:1992) |
HD 478.2.4 : 200S1 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - ENVIRONMENTAL CONDITIONS APPEARING IN NATURE - SOLAR RADIATION AND TEMPERATURE |
EN 60721-2-2:2013 | Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
EN 61439-2:2011 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 2: POWER SWITCHGEAR AND CONTROLGEAR ASSEMBLIES (IEC 61439-2:2011) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC TR 61641:2014 | Enclosed low-voltage switchgear and controlgear assemblies - Guide for testing under conditions of arcing due to internal fault |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
ISO 1920-4:2005 | Testing of concrete Part 4: Strength of hardened concrete |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
CLC/TS 62271-304:2008 | High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and including 52 kV to be used in severe climatic conditions |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
EN 60243-1:2013 | ELECTRIC STRENGTH OF INSULATING MATERIALS - TEST METHODS - PART 1: TESTS AT POWER FREQUENCIES (IEC 60243-1:2013) |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
ISO 9227:2017 | Corrosion tests in artificial atmospheres — Salt spray tests |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC TR 62271-208:2009 | High-voltage switchgear and controlgear - Part 208: Methods to quantify the steady state, power-frequency electromagnetic fields generated by HV switchgear assemblies and HV/LV prefabricated substations |
EN 60059:1999/A1:2009 | |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
IEC 60721-2-4:1987+AMD1:1988 CSV | Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature |
ISO 1460:1992 | Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area |
EN 60721-1:1995/A2:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 1: ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES |
IEC 60059:1999+AMD1:2009 CSV | IEC standard current ratings |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 60076-13:2006 | Power transformers - Part 13: Self-protected liquid-filled transformers |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 2409:2013 | Paints and varnishes Cross-cut test |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN ISO 1716:2010 | Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010) |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
EN 61180-1:1994 | High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 62271-4 : 2013 | High-voltage switchgear and controlgear - Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures |
ISO 3231:1993 | Paints and varnishes — Determination of resistance to humid atmospheres containing sulfur dioxide |
IEC 61439-2:2011 | Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.