BS EN 62040-5-3:2017
Current
The latest, up-to-date edition.
Uninterruptible power systems (UPS) DC output UPS. Performance and test requirements
Hardcopy , PDF
English
28-02-2017
Committee |
PEL/22
|
DevelopmentNote |
Supersedes 14/30297921 DC. (02/2017)
|
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC62040 establishes the performance and test requirements applied to movable, stationary and fixed electronic DC uninterruptible power systems (DC UPS) that are supplied from an AC voltage source not exceeding 1000V, deliver a DC output voltage not exceeding 1500V, incorporate an energy storage device, and have a primary function to ensure continuity of DC power to loads. This document specifies performance and test requirements of a complete DC UPS and not of individual DC UPS functional units. The individual DC UPS functional units are dealt with in IEC publications referred to in the bibliography that apply so far that they are not in contradiction with this document. DC UPSs have been developed over a wide range of power, from less than a hundred watts to megawatts, to meet requirements for availability and quality of power to a variety of loads. Refer to AnnexesA and B for information on typical DC UPS configurations and topologies. This document also includes DC UPS performance and test requirements related to interrupters, isolating switches, and tie switches, if any, which are integral to the DC UPS. These components interact with other functional units of the DC UPS to maintain continuity of load power. This document does not cover conventional AC input distribution boards and their associated switches, conventional DC distribution boards and their associated switches, conventional AC UPSs covered by IEC62040‑3 , low-voltage DC power supply devices covered by a specific product standard, for example IEC61204 , and those covered by a specific product standard, for example ITU communication standards, and systems wherein the output voltage is derived from a rotating machine. NOTE1 This document recognises that power availability to information technology (IT) equipment represents a major UPS application. The DC UPS output characteristics specified in this document are therefore also aimed at ensuring compatibility with the requirements of IT equipment. This, subject to any limitation stated in the manufacturer’s declaration, includes requirements for steady state and transient voltage variation as well as for the supply of both resistive and constant power load characteristics of IT equipment. NOTE2 Test loads specified in this document simulate both resistive and constant power load characteristics. Their use is prescribed with the objective of verifying design and performance, as declared by the manufacturer, and also of minimising any complexity and energy consumption during the tests.
Standards | Relationship |
EN 62040-5-3:2017 | Identical |
IEC 62040-5-3:2016 | Identical |
EN 60335-2-51:2003/A1:2008 | Identical |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60146-1-3:1991 | Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors |
IEC 60068-2-5:2010 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
EN 62040-1:2008/A1:2013 | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: GENERAL AND SAFETY REQUIREMENTS FOR UPS (IEC 62040-1:2008/A1:2013) |
EN 60146-1-1:2010 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60034-22:2009 | Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60950-1:2006/A2:2013 | INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED) |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
IEC 62040-1:2017 EXV | UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 1: SAFETY REQUIREMENTS |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
EN 60068-3-3:1993 | Environmental testing - Part 3: Guidance - Seismic test methods for equipments |
EN 60146-1-3:1993 | Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors |
EN 60947-3:2009/A2:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015) |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 62040-2:2016 | Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC TR 60721-4-0:2002 | Classification of environmental conditions - Part 4-0: Guidance for the correlation and transformation of the environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Introduction |
IEC TR 60721-4-3:2001+AMD1:2003 CSV | Classification of environmental conditions - Part 4-3: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Stationary use at weatherprotected locations |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
IEC 60146-1-1:2009 | Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements |
IEC 60146-2:1999 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN ISO 7779:2010 | Acoustics - Measurement of airborne noise emitted by information technology and telecommunications equipment (ISO 7779:2010) |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60146-2:2000 | Semiconductor converters - Part 2: Self-commutated semiconductor converters including direct d.c. converters |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-13:1999 | Environmental testing - Part 2: Tests - Test M: Low air pressure |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
EN 62040-2:2006/corrigendum:2006 | |
IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
EN 60034-22:2009 | Rotating electrical machines - Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets |
EN 60947-6-1:2005/A1:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT (IEC 60947-6-1:2005/A1:2013) |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-5:2011 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
ISO 7779:2010 | Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
EN 60990:2016 | Methods of measurement of touch current and protective conductor current |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.