BS EN 62035:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Discharge lamps (excluding fluorescent lamps). Safety specifications
Hardcopy , PDF
27-09-2019
English
31-01-2015
1 Scope
2 Normative references
3 Terms and definitions
4 General safety requirements
5 Particular safety requirements
6 Information for luminaire design
7 Assessment
Annex A (normative) - List of lamp caps and gauges
Annex B (normative) - Pull and torsion test values
Annex C (normative) - Torsion test holders
Annex D (normative) - Information for thermal tests
Annex E (normative) - Measurement of pulse height for lamps
with internal starting device
Annex F (informative) - Information for luminaire design
Annex G (normative) - Conditions of compliance for design
tests
Annex H (normative) - Symbols
Annex I (normative) - Containment testing procedure
for metal halide lamps with quartz arc tubes
Annex J (normative) - Containment testing procedure for
metal halide lamps with ceramic arc tubes
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes the safety requirements for discharge lamps (excluding fluorescent lamps) for general lighting purposes.
Committee |
CPL/34/1
|
DevelopmentNote |
Together with BS EN 60188, supersedes BS 3677(1989) Supersedes 98/200606 DC (12/2001) Supersedes 01/207522 DC. (02/2004) Supersedes 12/30258551 DC. (02/2015)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This International Standard specifies the safety requirements for discharge lamps (excluding fluorescent lamps) for general lighting purposes. This International Standard is applicable to low-pressure sodium vapour lamps and to high-intensity discharge (HID) lamps, i.e. high-pressure mercury vapour lamps (including This standard only concerns safety criteria and does not take into account performance. The performance standards IEC60188 , IEC60192 , IEC60662 , IEC61167 and IEC61549 should be referred to for such characteristics. It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90% and 110% of rated supply voltage and when operated with a ballast complying with IEC61347‑2‑9 and IEC60923 , with a starting device complying with IEC61347‑2‑1 and IEC60927 , and in a luminaire complying with IEC60598‑1 .
Standards | Relationship |
I.S. EN 62035:2014 | Identical |
DIN EN 62035 : 2015 | Identical |
NF EN 62035 : 2017 | Identical |
IEC 62035:2014+AMD1:2016 CSV | Identical |
NBN EN 62035 : 2015 | Identical |
UNE-EN 62035:2015 | Identical |
SN EN 62035 : 2014 | Identical |
EN 62035:2014 | Identical |
07/30130630 DC : 0 | BS 7430 - CODE OF PRACTICE FOR EARTHING |
IEC 60432-1:1999+AMD1:2005+AMD2:2011 CSV | Incandescent lamps - Safety specifications - Part 1: Tungsten filament lamps for domestic and similar general lighting purposes |
IEC 60061-3:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges |
IEC TR 62778:2014 | Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 61347-2-9:2012 | Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) |
IEC 60061-2:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 2: Lampholders |
EN 61347-2-1:2001/A2:2014 | LAMP CONTROLGEAR - PART 2-1: PARTICULAR REQUIREMENTS FOR STARTING DEVICES (OTHER THAN GLOW STARTERS) (IEC 61347-2-1:2000/A2:2013) |
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV | Lamp controlgear - Part 2-1: Particular requirements for startingdevices (other than glow starters) |
EN 60923:2005/A1:2006 | AUXILIARIES FOR LAMPS - BALLASTS FOR DISCHARGE LAMPS (EXCLUDING TUBULAR FLUORESCENT LAMPS) - PERFORMANCE REQUIREMENTS |
IEC 61167:2015 | Metal halide lamps - Performance specification |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60061-4:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 4: Guidelines and general information |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 62471:2006 | Photobiological safety of lamps and lamp systems |
IEC 60927:2007+AMD1:2013 CSV | Auxiliaries for lamps - Starting devices (other than glow starters)- Performance requirements |
EN 60155:1995/A2:2007 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
EN 60662:2012 | High-pressure sodium vapour lamps - Performance specifications |
ISO 4046-4:2002 | Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
IEC 60923:2005+AMD1:2006 CSV | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.