1 Scope
2 Normative references
3 Submission for testing
4 Conformance
5 Preliminary inspection
6 Power supply
7 Environmental conditions
8 General test requirements
9 Sound calibrator
10 Indication at the calibration check frequency
11 Self-generated noise
12 Acoustical signal tests of a frequency weighting
13 Electrical signal tests of frequency weightings
14 Frequency and time weightings at 1 kHz
15 Long-term stability
16 Level linearity on the reference level range
17 Level linearity including the level range control
18 Toneburst response
19 C-weighted peak sound level
20 Overload indication
21 High-level stability
22 Documentation
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

Specifies procedures for periodic testing of time-weighting, integrating-averaging, and integrating sound level meters that were designed to conform to the class 1 or class 2 specifications of the second edition of IEC 61672-1.

Committee
EPL/29
DevelopmentNote
Supersedes 04/30110612 DC. (02/2007) Supersedes 09/30208595 DC. (01/2014)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC 61672-3:2013 describes procedures for periodic testing of time-weighting, integrating-averaging, and integrating sound level meters that were designed to conform to the class 1 or class 2 specifications of the second edition of IEC 61672-1. The aim of the standard is to ensure that periodic testing is performed in a consistent manner by all laboratories. The purpose of periodic testing is to assure the user that the performance of a sound level meter conforms to the applicable specifications of IEC 61672-1 for a limited set of key tests and for the environmental conditions under which the tests were performed. Periodic tests described in this edition of IEC 61672-3 apply to sound level meters for which the manufacturer claims conformance to the specifications of the second edition of IEC 61672-1. Periodic tests described in IEC 61672-3 apply to sound level meters for which the model has been, or has not been, pattern approved by an independent testing organization responsible for pattern approvals in accordance with the test procedures of the second edition of IEC61672-2. This second edition cancels and replaces the first edition published in 2006. This second edition constitutes a technical revision. The main changes with regard to the previous concern conformance to specifications which is now demonstrated when measured deviations from design goals do not exceed the applicable acceptance limits, and when the uncertainty of measurement does not exceed the corresponding maximum-permitted uncertainty, with both uncertainties determined for a coverage probability of 95 %. In this document, references to IEC 61672-1, IEC 61672-2, and IEC 61672-3 refer to the second editions unless stated otherwise. Procedures for the periodic testing of sound level meters designed to conform to the specifications of IEC 61672-1:2002 were given in IEC 61672-3:2006.

Standards Relationship
EN 61672-3:2013 Identical
DIN EN 61672-3:2017-05 Identical
NBN EN 61672-3 : 2014 Identical
IEC 61672-3:2013 Identical
I.S. EN 61672-3:2013 Identical
NF EN 61672-3 : 2014 Identical

14/30268407 DC : 0 BS 4142 - METHODS FOR RATING AND ASSESSING INDUSTRIAL AND COMMERCIAL SOUND
13/30258085 DC : 0 BS 5228-1:2009+A1 - CODE OF PRACTICE FOR NOISE AND VIBRATION CONTROL ON CONSTRUCTION AND OPEN SITES - PART 1: NOISE
BS 5228-1(2009) : 2009 CODE OF PRACTICE FOR NOISE AND VIBRATION CONTROL ON CONSTRUCTION AND OPEN SITES - PART 1: NOISE

IEC 61672-2:2013+AMD1:2017 CSV Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests
EN 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
IEC 61094-5:2016 Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison
EN 61094-5:2016 Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison
IEC 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
EN 61672-2:2013/A1:2017 ELECTROACOUSTICS - SOUND LEVEL METERS - PART 2: PATTERN EVALUATION TESTS (IEC 61672-2:2013/A1:2017)
IEC 60942:2003 Electroacoustics - Sound calibrators
EN 62585 : 2012 ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER (IEC 62585:2012)
EN 61094-6:2005 Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications
IEC 61094-6:2004 Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
EN 60942:2003 Electroacoustics - Sound calibrators
IEC 62585:2012 Electroacoustics - Methods to determine corrections to obtain the free-field response of a sound level meter
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more