Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 61557-8:2015

Current

Current

The latest, up-to-date edition.

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Insulation monitoring devices for IT systems

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-06-2016

$618.22
Including GST where applicable

1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Marking and operating instructions
6 Tests
7 Overview of requirements and tests for IMDs
Annex A (normative) - Medical insulation monitoring devices
        (MED-IMD)
Annex B (informative) - Monitoring of overload current and
        over-temperature
Annex C (normative) - Insulation monitoring devices for photovoltaic
        systems (PV-IMD)
Annex D (normative) - Insulation monitoring function of a photovoltaic
        inverter (PV-IMF) or in a charge controller
Bibliography
Annex ZA (normative) - Normative references to
         international publications with
         their corresponding European publications

Defines the requirements for insulation monitoring devices (IMD) which permanently monitor the insulation resistance R[F] to earth of unearthed a.c. IT systems, of a.c. IT systems with galvanically connected d.c. circuits having nominal voltages up to 1000 V a.c., as well as of unearthed d.c. IT systems with voltages up to 1500 V d.c. independent from the method of measuring.

Committee
PEL/85
DevelopmentNote
Supersedes 95/200309 DC. (09/2005) Supersedes 04/30125208 DC. (11/2007) Supersedes 12/30274733 DC. (02/2015)
DocumentType
Standard
Pages
52
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC61557 specifies the requirements for insulation monitoring devices (IMD) which permanently monitor the insulation resistance R F to earth of unearthed a.c. IT systems, of a.c. IT systems with galvanically connected d.c. circuits having nominal voltages up to 1000V a.c., as well as of unearthed d.c. IT systems with voltages up to 1500V d.c. independent from the method of measuring. IT systems are described in IEC60364‑4‑41 amongst other literature. Additional data for the selection of devices in other standards should be noted. NOTE Various standards specify the use of IMDs in IT systems. In such cases, the objective of the equipment is to signal a drop in insulation resistance R F below a minimum limit. IMDs according to this part of IEC61557 can also be used for de-energized TT, TN and IT systems or appliances.

BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

IEC 60947-5-4:2002 Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests
EN 60027-7:2010 Letter symbols to be used in electrical technology - Part 7: Power generation, transmission and distribution
IEC 60364-7-712:2017 Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems
EN 60721-3-1:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage
IEC 61326-2-4:2012 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9
IEC 60364-7-710:2002 Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
HD 60364-4-41:2017/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
EN 60947-5-4:2003 Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests
EN 61810-2:2017 Electromechanical elementary relays - Part 2: Reliability
IEC 61010-2-030:2017 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC 61557-1:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
IEC 61810-2:2017 Electromechanical elementary relays - Part 2: Reliability
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60691:2015 Thermal-links - Requirements and application guide
IEC 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
HD 60364-7-712:2016 Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems
IEC 62109-2:2011 Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters
EN 61557-1:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements
HD 60364-7-710:2012/AC:2013 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-710: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MEDICAL LOCATIONS
EN 62109-2:2011 Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 61557-9:2014 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
EN 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
EN 61326-2-4:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60027-7:2010 Letter symbols to be used in electrical technology - Part 7: Power generation, transmission and distribution
EN 61557-9:2015/AC:2017-02 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017)
EN 60664-3:2017 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60721-3-1:1997 Classification of environmental conditions - Part 3 Classification of groups of environmental parameters and their severities - Section 1: Storage
EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.