BS EN 61547:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Equipment for general lighting purposes. EMC immunity requirements

Available format(s)

Hardcopy , PDF

Superseded date

18-04-2023

Superseded by

BS EN IEC 61547:2023

Language(s)

English

Published date

31-07-2010

$319.77
Including GST where applicable

Committee
CPL/34
DevelopmentNote
Supersedes 93/212631 DC (09/2001) Supersedes 98/201449 DC. (05/2005) Supersedes 07/30166127 DC. (01/2010)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This International Standard for electromagnetic immunity requirements applies to lighting equipment which is within the scope of IEC technical committee 34, such as lamps, auxiliaries and luminaires, intended either for connecting to a low voltage electricity supply or for battery operation.

Excluded from the scope of this standard is equipment for which the immunity requirements are formulated in other IEC or CISPR standards such as:

  • lighting equipment for use in transport vehicles;

  • entertainment lighting control equipment for professional purposes;

  • lighting devices built into other equipment such as:

    • scale illumination or indicators;

    • photocopiers;

    • slide and overhead projectors;

    • multimedia equipment.

However, in multi-function equipment where the lighting part operates independently from other parts, the electromagnetic immunity requirements of this standard apply to the lighting part.

The requirements of this standard are based on the requirements for domestic, commercial and light-industrial environments as given in IEC 61000-6-1, but modified to lighting engineering practice.

It can be expected that lighting equipment complying with the requirements of this standard will operate satisfactorily in other environments. In some special cases, measures have to be taken to provide higher immunity. It is impracticable to deal with all these possibilities. Such requirements may be established by contractual agreement between supplier and purchaser.

Standards Relationship
IEC 61547:2009/COR1:2010 Identical
NBN EN 61547 : 2009 Identical
I.S. EN 61547:2009 Identical
SN EN 61547 : 1995 AMD 1 2000 Identical
DIN EN 61547 : 2010 COR 1 2010 Identical
UNE-EN 61547:2011 Identical
NF EN 61547 : 2009 Identical
IEC 61547:2009 Identical
EN 61547:2009 Identical

EN 61000-6-1:2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60050-845:1987 International Electrotechnical Vocabulary (IEV) - Part 845: Lighting
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
2004/108/EC : 2004 DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 60598-2-22:2014/AC:2016-09 LUMINAIRES - PART 2-22: PARTICULAR REQUIREMENTS - LUMINAIRES FOR EMERGENCY LIGHTING (IEC 60598-2-22:2014/COR2:2016)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more