BS EN 61481-2:2014
Current
The latest, up-to-date edition.
Live working. Phase comparators Resistive type to be used for voltages from 1 kV to 36 kV a.c.
Hardcopy , PDF
English
31-01-2015
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Tests
6 Conformity assessment of phase comparators
having completed the production phase
7 Modifications
Annex A (normative) - Instructions for use
Annex B (normative) - Suitable for live working; double
triangle (IEC 60417-5216(2002-10))
Annex C (normative) - Chronology of type tests
Annex D (normative) - Classification of defects and tests
to be allocated
Annex E (informative) - Information and guidelines on the
use of the limit mark and of a contact electrode
extension
Annex F (informative) - Rationale for the classification of
defects
Annex G (informative) - In-service care
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to portable phase comparators of resistive type to be used on electrical systems for voltages from 1 kV a.c. to 36 kV a.c. and frequencies of 50 Hz and/or 60 Hz.
Committee |
PEL/78
|
DevelopmentNote |
Together with BS EN 61481-1, it supersedes BS EN 61481. Supersedes 13/30267625 DC. (01/2015)
|
DocumentType |
Standard
|
Pages |
82
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC61481 is applicable to portable phase comparators of resistive type to be used on electrical systems for voltages from 1kV a.c. to 36kV a.c. and frequencies of 50Hz and/or 60Hz. This standard is applicable to phase comparators of resistive type used in contact with the bare conductive parts to be compared: as a complete device including its insulating element or as a separate device, adaptable to an insulating stick which, as a separate tool, is not covered by this standard. NOTE Some parts such as the contact electrode or the insulating element of a phase comparator as a complete device may be dismantled. Some restrictions on their use are applicable in the case of factory-assembled switchgear and on overhead systems of electrified railways (see AnnexA). A device that is designed to provide other functions than phase comparison is a different device and is not covered by this standard. For examplea device designed to be also used as a voltage detector is not covered by this standard (see AnnexA). Products designed and manufactured according to this standard contribute to the safety of the users provided they are used by persons trained for the work, in accordance with the hot stick working method and the instructions for use. Except when otherwise specified, all the voltages defined in this standard refer to phase-to-phase voltages of three-phase systems. In other systems, the applicable phase-to-phase or phase-to-earth (ground) voltages should be used to determine the operating voltage.
Standards | Relationship |
EN 61481-2:2014 | Identical |
IEC 61481-2:2014 | Identical |
IEC 61477:2009 | Live working - Minimum requirements for the utilization of tools, devices and equipment |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 60038:2009 | IEC standard voltages |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 3744:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane |
IEC 61235:1993 | Live working - Insulating hollow tubes for electrical purposes |
IEC 60855-1:2016 | Live working - Insulating foam-filled tubes and solid rods - Part 1: Tubes and rods of a circular cross-section |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60942:2003 | Electroacoustics - Sound calibrators |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60743:2013 | Live working - Terminology for tools, devices and equipment |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 60743:2013 | Live working - Terminology for tools, devices and equipment |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
EN 61318:2008 | Live working - Conformity assessment applicable to tools, devices and equipment |
EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 61326-1:2013 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 61477:2009/corrigendum:2010 | LIVE WORKING - MINIMUM REQUIREMENTS FOR THE UTILIZATION OF TOOLS, DEVICES AND EQUIPMENT |
EN ISO 3744:2010 | Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2010) |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61318:2007 | Live working - Conformity assessment applicable to tools, devices and equipment |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
IEC TR 61000-2-1:1990 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems |
EN 61235:1995 | Live working - Insulating hollow tubes for electrical purposes |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60050-651:2014 | International Electrotechnical Vocabulary (IEV) - Part 651: Live working |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
EN 60942:2003 | Electroacoustics - Sound calibrators |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 61260:1995/A1:2001 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS |
EN 60038:2011 | CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |