BS EN 61347-2-7:2012+A1:2019
Current
The latest, up-to-date edition.
Lamp controlgear Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
31-07-2019
This part of IEC 61347 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes.
Committee |
CPL/34/3
|
DocumentType |
Standard
|
ProductNote |
THIS STANDARD IS ALSO IDENTICAL TO:IEC 61347-2-7:2011/AMD1:2017,EN 60081:1998/A4:2010, EN 60081:1998/A3:2005, EN 61558-1:2005,EN 60929:2011, EN 61558-2-16:2009, EN 60081:1998/A1:2002, EN 60929:2011/AC:2011,EN 60901:1996/A4:2008, EN 60901:1996/A3:2004, EN 60921:2004, EN 60081:1998/A6:2017, EN 60081:1998/A5:2013,EN 61347-2-3:2011/AC:2011,EN 60901:1996/A2:2000, EN 60081:1998/A2:2003, EN 60081:1998, EN 60598-2-22:2014, EN 61347-2-3:2011, EN 61347-1:2015, EN 60081:1998/A11:2018, FprA1:2017, EN 60901, EN 61347-2-13
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC61347 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes.It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC60598‑2‑22.It is intended for controlgear for fluorescent lamps, but it is also applicable to other lamp typese.g. incandescent, high pressure discharge lamps and LEDs.This standard covers the emergency mode operation of a controlgear. For controlgear with a combination of normal and emergency lighting operation, the normal lighting operation aspects are covered by the appropriate part2 of IEC61347.DC supplied electronic controlgear for emergency lighting may or may not include batteries.This standard does not apply to d.c. supplied electronic controlgear for emergency lighting, which are intended for connection to a centralised emergency power supply system. A centralised emergency power system could be a central battery system.NOTE AnnexJ of IEC61347‑2‑3 applies to a.c., a.c./d.c. or d.c. supplied electronic controlgear for connection to centralised emergency power supply systems that are also intended for emergency lighting operations from a.c./d.c. supplies.
Standards | Relationship |
EN 61347-2-7:2012/A1:2019 | Identical |
IEC 61347-2-7:2011/AMD1:2017 | Identical |
IEC 61347-2-3:2011+AMD1:2016 CSV | Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps |
IEC 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
IEC 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
IEC 61558-2-16:2009+AMD1:2013 CSV | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-16: Particularrequirements and tests for switch mode power supply units andtransformers for switch mode power supply units |
IEC 60929:2011+AMD1:2015 CSV | AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60921:2004/A1:2006 | BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS |
IEC 60921:2004+AMD1:2006 CSV | Ballasts for tubular fluorescent lamps - Performance requirements |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV | Single-capped fluorescent lamps - Performance specifications |
EN 61558-2-1:2007 | Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
EN 60901:1996/A6:2017 | SINGLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS (IEC 60901:1996/A6:2014, MODIFIED) |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.