INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions
15 Heating of built-in and independent starting devices
16 Pulse voltage of ignitors
17 Mechanical strength
18 Construction
19 Creepage distances and clearances
20 Screws, current-carrying parts and connections
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
Annex A (normative) - Test to establish whether a
conductive part is a live part which may
cause an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp controlgear
Annex C (normative) - Particular requirements for
electronic lamp controlgear with means
of protection against overheating
Annex D (normative) - Requirements for carrying
out the heating tests of thermally protected
lamp controlgear
Annex E (normative) - Use of constant S other than
4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (informative) - Explanation of the derivation
of the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Mechanical strength testing
Annex J (normative) - Precautions to be observed when
measuring with sphere-gaps
Annex ZA (normative) - Normative references to
international publications with the
corresponding European publications
Bibliography
Defines particular safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in combination with lamps and ballasts covered in IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, IEC 61195, IEC 61199, IEC 61347-2-8 and IEC 61347-2-9.
Committee |
CPL/34/3
|
DevelopmentNote |
Together with BS EN 61347-1, it supersedes BS EN 60926. (04/2001) Supersedes 98/263269 DC. (10/2003) Supersedes 04/300382 DC. (06/2006) 2001 Edition Re-Issued in May 2014 & incorporates AMD 2 2014. Supersedes 11/30241984 DC. (05/2014)
|
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 61347-2-1 : 2014 | Identical |
SN EN 61347-2-1 : 2001 AMD 1 2006 | Identical |
EN 61347-2-1:2001/A2:2014 | Identical |
I.S. EN 61347-2-1:2004 | Identical |
NF EN 61347-2-1 : 2001 AMD 2 2014 | Identical |
IEC 61347-2-1:2000+AMD1:2005+AMD2:2013 CSV | Identical |
UNE-EN 61347-2-1:2002 | Identical |
EN 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
EN 60192:2001 | Low pressure sodium vapour lamps - Performance specifications |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60662:2011 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60192:2001 | Low-pressure sodium vapour lamps - Performance specifications |
IEC 60188:2001 | High-pressure mercury vapour lamps - Performance specifications |
EN 61199:2011/A2:2015 | SINGLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61199:2011/A2:2014) |
IEC 61347-1:2015 RLV | Lamp controlgear - Part 1: General and safety requirements |
EN 60255-8:1998 | Electrical relays - Part 8: Thermal electrical relays |
IEC 61199:2011+AMD1:2012+AMD2:2014 CSV | Single-capped fluorescent lamps - Safety specifications |
IEC 61167:2015 | Metal halide lamps - Performance specification |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
EN 61347-1:2015 | Lamp controlgear - Part 1: General and safety requirements |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60927:2007+AMD1:2013 CSV | Auxiliaries for lamps - Starting devices (other than glow starters)- Performance requirements |
IEC 60255-8:1990 | Electrical relays - Part 8: Thermal electrical relays |
IEC 60052:2002 | Voltage measurement by means of standard air gaps |
EN 60155:1995/A2:2007 | GLOW-STARTERS FOR FLUORESCENT LAMPS |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 60662:2012 | High-pressure sodium vapour lamps - Performance specifications |
IEC 60155:1993 | Glow-starters for fluorescent lamps |
ISO 3864:1984 | Safety colours and safety signs |
EN 61195:1999/A2:2015 | DOUBLE-CAPPED FLUORESCENT LAMPS - SAFETY SPECIFICATIONS (IEC 61195:1999/A2:2014) |
IEC 61195:1999+AMD1:2012+AMD2:2014 CSV | Double-capped fluorescent lamps - Safety specifications |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.